机械干扰对傅立叶变换干涉仪中参考光位置的影响。

IF 1.3 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION
Muqian Wen
{"title":"机械干扰对傅立叶变换干涉仪中参考光位置的影响。","authors":"Muqian Wen","doi":"10.1063/5.0235081","DOIUrl":null,"url":null,"abstract":"<p><p>Fourier transform interferometers usually need a dedicated reference light to precisely track optical path difference changes. There are a few different ways to incorporate the reference light into the optical system. This paper conducted experiments to give a test of how different ways of incorporating reference light are affected by mechanical disturbances. It found that placing the reference light in a different path than the test light can be very sensitive to mechanical disturbance errors, while propagating the reference light together with the test light can be very robust against mechanical vibrations of optical components.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"95 11","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact of mechanical disturbances to the placement of reference light in Fourier transform interferometers.\",\"authors\":\"Muqian Wen\",\"doi\":\"10.1063/5.0235081\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Fourier transform interferometers usually need a dedicated reference light to precisely track optical path difference changes. There are a few different ways to incorporate the reference light into the optical system. This paper conducted experiments to give a test of how different ways of incorporating reference light are affected by mechanical disturbances. It found that placing the reference light in a different path than the test light can be very sensitive to mechanical disturbance errors, while propagating the reference light together with the test light can be very robust against mechanical vibrations of optical components.</p>\",\"PeriodicalId\":21111,\"journal\":{\"name\":\"Review of Scientific Instruments\",\"volume\":\"95 11\",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Review of Scientific Instruments\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0235081\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0235081","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

傅立叶变换干涉仪通常需要专用的参考光来精确跟踪光路差变化。将参考光纳入光学系统有几种不同的方法。本文通过实验测试了不同的参考光加入方式如何受到机械干扰的影响。实验发现,将参考光置于与测试光不同的路径上会对机械干扰误差非常敏感,而将参考光与测试光一起传播则能很好地抵御光学元件的机械振动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of mechanical disturbances to the placement of reference light in Fourier transform interferometers.

Fourier transform interferometers usually need a dedicated reference light to precisely track optical path difference changes. There are a few different ways to incorporate the reference light into the optical system. This paper conducted experiments to give a test of how different ways of incorporating reference light are affected by mechanical disturbances. It found that placing the reference light in a different path than the test light can be very sensitive to mechanical disturbance errors, while propagating the reference light together with the test light can be very robust against mechanical vibrations of optical components.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信