Ahmad Mohammadi Pour , Mehrdad Setayesh Nazar , Miadreza Shafie-khah , Zita Vale
{"title":"考虑弹性投资备选方案的自愈配电系统优化扩展规划","authors":"Ahmad Mohammadi Pour , Mehrdad Setayesh Nazar , Miadreza Shafie-khah , Zita Vale","doi":"10.1016/j.energy.2024.133625","DOIUrl":null,"url":null,"abstract":"<div><div>This paper proposes a three-stage optimization framework for the expansion planning of a self-healing distribution system that determines the optimal characteristics of distributed generation, energy storage systems, electric vehicle charging stations, and sectionalizing switches for the planning horizon. The main contribution of this model is that the proposed model considers the resilient investment alternatives in the expansion planning exercise to reduce the system's vulnerability against external shocks. The mobile energy storage system commitment in contingent conditions is another contribution of this paper. In the first stage, the optimal location, capacity, and time of installation of the electricity facilities are calculated. Then, the optimal allocation of sectionalizing switches is performed in the second stage. The third stage consists of three levels. In the first and second levels, the optimal normal and contingent operational scheduling are determined, respectively. The system is sectionalized into multi-microgrid systems in contingent conditions. Finally, the resilient investment alternatives for the designed system are evaluated. The proposed model utilizes a self-healing index and resilient expansion planning index to assess the impacts of resilient investment alternatives on the operational scheduling conditions. The proposed model was evaluated using the IEEE 123-bus system. The proposed method reduced the estimated average value of the worst-case energy not supplied by 50.52 % for the 5th year of the planning horizon concerning the no-resiliency investment case. Further, the proposed resilience investment method increased the self-healing index by about 9.32 % concerning the no-resiliency investment case.</div></div>","PeriodicalId":11647,"journal":{"name":"Energy","volume":"313 ","pages":"Article 133625"},"PeriodicalIF":9.0000,"publicationDate":"2024-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimal expansion planning of a self-healing distribution system considering resiliency investment alternatives\",\"authors\":\"Ahmad Mohammadi Pour , Mehrdad Setayesh Nazar , Miadreza Shafie-khah , Zita Vale\",\"doi\":\"10.1016/j.energy.2024.133625\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>This paper proposes a three-stage optimization framework for the expansion planning of a self-healing distribution system that determines the optimal characteristics of distributed generation, energy storage systems, electric vehicle charging stations, and sectionalizing switches for the planning horizon. The main contribution of this model is that the proposed model considers the resilient investment alternatives in the expansion planning exercise to reduce the system's vulnerability against external shocks. The mobile energy storage system commitment in contingent conditions is another contribution of this paper. In the first stage, the optimal location, capacity, and time of installation of the electricity facilities are calculated. Then, the optimal allocation of sectionalizing switches is performed in the second stage. The third stage consists of three levels. In the first and second levels, the optimal normal and contingent operational scheduling are determined, respectively. The system is sectionalized into multi-microgrid systems in contingent conditions. Finally, the resilient investment alternatives for the designed system are evaluated. The proposed model utilizes a self-healing index and resilient expansion planning index to assess the impacts of resilient investment alternatives on the operational scheduling conditions. The proposed model was evaluated using the IEEE 123-bus system. The proposed method reduced the estimated average value of the worst-case energy not supplied by 50.52 % for the 5th year of the planning horizon concerning the no-resiliency investment case. Further, the proposed resilience investment method increased the self-healing index by about 9.32 % concerning the no-resiliency investment case.</div></div>\",\"PeriodicalId\":11647,\"journal\":{\"name\":\"Energy\",\"volume\":\"313 \",\"pages\":\"Article 133625\"},\"PeriodicalIF\":9.0000,\"publicationDate\":\"2024-11-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0360544224034030\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0360544224034030","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
Optimal expansion planning of a self-healing distribution system considering resiliency investment alternatives
This paper proposes a three-stage optimization framework for the expansion planning of a self-healing distribution system that determines the optimal characteristics of distributed generation, energy storage systems, electric vehicle charging stations, and sectionalizing switches for the planning horizon. The main contribution of this model is that the proposed model considers the resilient investment alternatives in the expansion planning exercise to reduce the system's vulnerability against external shocks. The mobile energy storage system commitment in contingent conditions is another contribution of this paper. In the first stage, the optimal location, capacity, and time of installation of the electricity facilities are calculated. Then, the optimal allocation of sectionalizing switches is performed in the second stage. The third stage consists of three levels. In the first and second levels, the optimal normal and contingent operational scheduling are determined, respectively. The system is sectionalized into multi-microgrid systems in contingent conditions. Finally, the resilient investment alternatives for the designed system are evaluated. The proposed model utilizes a self-healing index and resilient expansion planning index to assess the impacts of resilient investment alternatives on the operational scheduling conditions. The proposed model was evaluated using the IEEE 123-bus system. The proposed method reduced the estimated average value of the worst-case energy not supplied by 50.52 % for the 5th year of the planning horizon concerning the no-resiliency investment case. Further, the proposed resilience investment method increased the self-healing index by about 9.32 % concerning the no-resiliency investment case.
期刊介绍:
Energy is a multidisciplinary, international journal that publishes research and analysis in the field of energy engineering. Our aim is to become a leading peer-reviewed platform and a trusted source of information for energy-related topics.
The journal covers a range of areas including mechanical engineering, thermal sciences, and energy analysis. We are particularly interested in research on energy modelling, prediction, integrated energy systems, planning, and management.
Additionally, we welcome papers on energy conservation, efficiency, biomass and bioenergy, renewable energy, electricity supply and demand, energy storage, buildings, and economic and policy issues. These topics should align with our broader multidisciplinary focus.