{"title":"不同电池单元数量的湿垫辅助风冷电池热管理系统性能分析","authors":"Huaxia Yan ,&nbsp;Xiaona Ma ,&nbsp;Yi Chen ,&nbsp;Qiuhua Tao ,&nbsp;Mengjie Song","doi":"10.1016/j.applthermaleng.2024.124747","DOIUrl":null,"url":null,"abstract":"<div><div>Battery thermal management system is essential in electric vehicles to ensure thermal safety and efficient battery operation. Air-cooled battery thermal management technology is well-developed and inexpensive, but the small convection coefficient of air limits the heat dissipation capability of the system. Direct evaporative cooling, in the form of a wet pad, can be integrated to enlarge the cooling capacity through water evaporation. There is little research investigating the effectiveness of the system under varying number of battery cells. Besides, the minimum temperature of the battery pack is rarely discussed under various ambient conditions. Different from previous work, this paper aims to indicate the optimal working condition zones of a wet pad assisted air-cooled battery thermal management system. Thermal model of the wet pad and battery pack are established using MATLAB and Fluent software, respectively. Simulation results show that with the assistance of the wet pad, 4.9–6.2 °C cooler air would be produced, resulting in a 3.6–6.1 °C reduction in the maximum surface temperature of the battery but a slightly larger temperature difference among batteries. Better cooling performance of the wet pad can be obtained at arid ambient conditions. Using the wet pad, the optimal working condition zones of the battery pack are expanded because it is more capable of hot weather. Battery temperature control failed in the dry-air cooling cases at 2C discharge rate with 18 batteries and above, but with the wet pad, it can be controlled at 33.6 °C even with 60 batteries. Lastly, from an optimization viewpoint, by wrapping each battery with 0.5 mm aluminum flake, the maximum surface temperature and the temperature difference of the battery pack can be reduced by 4.1 % and 17.4 %, respectively. The findings will be beneficial for the design and optimization of a wet pad assisted air-cooled battery thermal management system.</div></div>","PeriodicalId":8201,"journal":{"name":"Applied Thermal Engineering","volume":"259 ","pages":"Article 124747"},"PeriodicalIF":6.1000,"publicationDate":"2024-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance analysis of a wet pad assisted air-cooled battery thermal management system with varying number of battery cells\",\"authors\":\"Huaxia Yan ,&nbsp;Xiaona Ma ,&nbsp;Yi Chen ,&nbsp;Qiuhua Tao ,&nbsp;Mengjie Song\",\"doi\":\"10.1016/j.applthermaleng.2024.124747\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Battery thermal management system is essential in electric vehicles to ensure thermal safety and efficient battery operation. Air-cooled battery thermal management technology is well-developed and inexpensive, but the small convection coefficient of air limits the heat dissipation capability of the system. Direct evaporative cooling, in the form of a wet pad, can be integrated to enlarge the cooling capacity through water evaporation. There is little research investigating the effectiveness of the system under varying number of battery cells. Besides, the minimum temperature of the battery pack is rarely discussed under various ambient conditions. Different from previous work, this paper aims to indicate the optimal working condition zones of a wet pad assisted air-cooled battery thermal management system. Thermal model of the wet pad and battery pack are established using MATLAB and Fluent software, respectively. Simulation results show that with the assistance of the wet pad, 4.9–6.2 °C cooler air would be produced, resulting in a 3.6–6.1 °C reduction in the maximum surface temperature of the battery but a slightly larger temperature difference among batteries. Better cooling performance of the wet pad can be obtained at arid ambient conditions. Using the wet pad, the optimal working condition zones of the battery pack are expanded because it is more capable of hot weather. Battery temperature control failed in the dry-air cooling cases at 2C discharge rate with 18 batteries and above, but with the wet pad, it can be controlled at 33.6 °C even with 60 batteries. Lastly, from an optimization viewpoint, by wrapping each battery with 0.5 mm aluminum flake, the maximum surface temperature and the temperature difference of the battery pack can be reduced by 4.1 % and 17.4 %, respectively. The findings will be beneficial for the design and optimization of a wet pad assisted air-cooled battery thermal management system.</div></div>\",\"PeriodicalId\":8201,\"journal\":{\"name\":\"Applied Thermal Engineering\",\"volume\":\"259 \",\"pages\":\"Article 124747\"},\"PeriodicalIF\":6.1000,\"publicationDate\":\"2024-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Thermal Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1359431124024153\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Thermal Engineering","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1359431124024153","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

电池热管理系统在电动汽车中至关重要,可确保热安全和电池的高效运行。风冷电池热管理技术已经发展成熟且成本低廉,但由于空气的对流系数较小,限制了系统的散热能力。可以集成湿垫形式的直接蒸发冷却,通过水蒸发扩大冷却能力。目前很少有研究调查该系统在不同电池数量下的有效性。此外,关于电池组在各种环境条件下的最低温度的讨论也很少。与以往的研究不同,本文旨在指出湿垫辅助风冷电池热管理系统的最佳工作条件区。本文分别使用 MATLAB 和 Fluent 软件建立了湿垫和电池组的热模型。仿真结果表明,在湿垫的辅助下,可产生 4.9-6.2 °C的低温空气,从而使电池的最高表面温度降低 3.6-6.1 °C,但电池之间的温差略大。在干旱的环境条件下,湿垫可以获得更好的冷却性能。使用湿垫后,电池组的最佳工作条件区扩大了,因为它更能适应炎热的天气。在干空气冷却情况下,电池组温度控制在 18 节电池及以上,放电率为 2 摄氏度时就会失效,而使用湿垫后,即使有 60 节电池,电池组温度也能控制在 33.6 摄氏度。最后,从优化的角度来看,用 0.5 毫米的铝片包裹每块电池,电池组的最高表面温度和温差可分别降低 4.1% 和 17.4%。这些发现将有助于湿垫辅助风冷电池热管理系统的设计和优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance analysis of a wet pad assisted air-cooled battery thermal management system with varying number of battery cells
Battery thermal management system is essential in electric vehicles to ensure thermal safety and efficient battery operation. Air-cooled battery thermal management technology is well-developed and inexpensive, but the small convection coefficient of air limits the heat dissipation capability of the system. Direct evaporative cooling, in the form of a wet pad, can be integrated to enlarge the cooling capacity through water evaporation. There is little research investigating the effectiveness of the system under varying number of battery cells. Besides, the minimum temperature of the battery pack is rarely discussed under various ambient conditions. Different from previous work, this paper aims to indicate the optimal working condition zones of a wet pad assisted air-cooled battery thermal management system. Thermal model of the wet pad and battery pack are established using MATLAB and Fluent software, respectively. Simulation results show that with the assistance of the wet pad, 4.9–6.2 °C cooler air would be produced, resulting in a 3.6–6.1 °C reduction in the maximum surface temperature of the battery but a slightly larger temperature difference among batteries. Better cooling performance of the wet pad can be obtained at arid ambient conditions. Using the wet pad, the optimal working condition zones of the battery pack are expanded because it is more capable of hot weather. Battery temperature control failed in the dry-air cooling cases at 2C discharge rate with 18 batteries and above, but with the wet pad, it can be controlled at 33.6 °C even with 60 batteries. Lastly, from an optimization viewpoint, by wrapping each battery with 0.5 mm aluminum flake, the maximum surface temperature and the temperature difference of the battery pack can be reduced by 4.1 % and 17.4 %, respectively. The findings will be beneficial for the design and optimization of a wet pad assisted air-cooled battery thermal management system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Thermal Engineering
Applied Thermal Engineering 工程技术-工程:机械
CiteScore
11.30
自引率
15.60%
发文量
1474
审稿时长
57 days
期刊介绍: Applied Thermal Engineering disseminates novel research related to the design, development and demonstration of components, devices, equipment, technologies and systems involving thermal processes for the production, storage, utilization and conservation of energy, with a focus on engineering application. The journal publishes high-quality and high-impact Original Research Articles, Review Articles, Short Communications and Letters to the Editor on cutting-edge innovations in research, and recent advances or issues of interest to the thermal engineering community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信