{"title":"三维打印扫描辅助工具的颜色对完整牙弓数字扫描真实性的影响。","authors":"Özay Önöral, Selin Çakır","doi":"10.1111/jopr.13969","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine the influence of using 3D-printed scan aids in varying colors on the trueness of digital scans.</p><p><strong>Materials and methods: </strong>A master cast with five multi-unit analogues was scanned. The acquired dataset was exported to standard tessellation language (STL) file format to serve as the reference STL. 3D printing of the prototype in five distinct colors (beige [SA<sup>BEIGE</sup>], grey [SA<sup>GREY</sup>], white [SA<sup>WHITE</sup>], red [SA<sup>RED</sup>], and blue [SA<sup>BLUE</sup>]) of polylactic acid filament was executed. The experimental STLs of each color group were aligned to the reference STL. RMS values were solely computed for the scan bodies. Based on the centers of the created best-fit and offset planes, scan bodies were converted into virtual cylinders. Cartesian coordinates of each cylinder were acquired. Subsequently, angular (AD) and linear deviation (LD) values were calculated. LD was further examined separately along the x, y, and z axes. Data were statistically analyzed.</p><p><strong>Results: </strong>According to the results of one-way ANOVAs, significant differences were detected among color groups on AD, LD, RMS estimate error, ∆x, ∆y, and ∆z data. The lowest AD and LD values were exhibited by the SA<sup>GREY</sup> group in all implant sites. The SA<sup>GREY</sup> group was followed by the SA<sup>BEIGE</sup>, SA<sup>WHITE</sup>, SA<sup>RED</sup>, and SA<sup>BLUE</sup> groups.</p><p><strong>Conclusions: </strong>The SA<sup>GREY</sup> outperformed the other groups in terms of trueness. Although the LD values of all color groups were below the threshold value (<100 µm), only the AD values of the SA<sup>GREY</sup>, SA<sup>BEIGE</sup>, and SA<sup>WHITE</sup> groups were clinically acceptable (<0.5°).</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":" ","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2024-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of the color of 3D-printed scan aids on the trueness of complete arch digital scans.\",\"authors\":\"Özay Önöral, Selin Çakır\",\"doi\":\"10.1111/jopr.13969\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To determine the influence of using 3D-printed scan aids in varying colors on the trueness of digital scans.</p><p><strong>Materials and methods: </strong>A master cast with five multi-unit analogues was scanned. The acquired dataset was exported to standard tessellation language (STL) file format to serve as the reference STL. 3D printing of the prototype in five distinct colors (beige [SA<sup>BEIGE</sup>], grey [SA<sup>GREY</sup>], white [SA<sup>WHITE</sup>], red [SA<sup>RED</sup>], and blue [SA<sup>BLUE</sup>]) of polylactic acid filament was executed. The experimental STLs of each color group were aligned to the reference STL. RMS values were solely computed for the scan bodies. Based on the centers of the created best-fit and offset planes, scan bodies were converted into virtual cylinders. Cartesian coordinates of each cylinder were acquired. Subsequently, angular (AD) and linear deviation (LD) values were calculated. LD was further examined separately along the x, y, and z axes. Data were statistically analyzed.</p><p><strong>Results: </strong>According to the results of one-way ANOVAs, significant differences were detected among color groups on AD, LD, RMS estimate error, ∆x, ∆y, and ∆z data. The lowest AD and LD values were exhibited by the SA<sup>GREY</sup> group in all implant sites. The SA<sup>GREY</sup> group was followed by the SA<sup>BEIGE</sup>, SA<sup>WHITE</sup>, SA<sup>RED</sup>, and SA<sup>BLUE</sup> groups.</p><p><strong>Conclusions: </strong>The SA<sup>GREY</sup> outperformed the other groups in terms of trueness. Although the LD values of all color groups were below the threshold value (<100 µm), only the AD values of the SA<sup>GREY</sup>, SA<sup>BEIGE</sup>, and SA<sup>WHITE</sup> groups were clinically acceptable (<0.5°).</p>\",\"PeriodicalId\":49152,\"journal\":{\"name\":\"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/jopr.13969\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.13969","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:确定使用不同颜色的 3D 打印扫描辅助工具对数字扫描真实性的影响:对一个包含五个多单元类似物的主铸件进行扫描。获取的数据集导出为标准细分语言(STL)文件格式,作为参考 STL。用五种不同颜色(米色[SABEIGE]、灰色[SAGREY]、白色[SAWHITE]、红色[SARED]和蓝色[SABLUE])的聚乳酸长丝对原型进行三维打印。每个颜色组的实验 STL 都与参考 STL 对齐。只计算扫描体的均方根值。根据创建的最佳拟合平面和偏移平面的中心,将扫描体转换为虚拟圆柱体。获取每个圆柱体的笛卡尔坐标。随后,计算角度偏差 (AD) 和线性偏差 (LD) 值。LD 沿 x、y 和 z 轴分别进行进一步检查。对数据进行了统计分析:根据单因素方差分析结果,各颜色组之间在 AD、LD、RMS 估计误差、Δx、Δy 和 Δz 数据上存在显著差异。在所有植入部位,SAGREY 组的 AD 和 LD 值最低。SAGREY 组之后是 SABEIGE、SAWHITE、SARED 和 SABLUE 组:结论:就真实度而言,SAGREY 组优于其他组。虽然所有颜色组的 LD 值都低于阈值(GREY、SABEIGE 和 SAWHITE 组在临床上可以接受 (
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of the color of 3D-printed scan aids on the trueness of complete arch digital scans.

Purpose: To determine the influence of using 3D-printed scan aids in varying colors on the trueness of digital scans.

Materials and methods: A master cast with five multi-unit analogues was scanned. The acquired dataset was exported to standard tessellation language (STL) file format to serve as the reference STL. 3D printing of the prototype in five distinct colors (beige [SABEIGE], grey [SAGREY], white [SAWHITE], red [SARED], and blue [SABLUE]) of polylactic acid filament was executed. The experimental STLs of each color group were aligned to the reference STL. RMS values were solely computed for the scan bodies. Based on the centers of the created best-fit and offset planes, scan bodies were converted into virtual cylinders. Cartesian coordinates of each cylinder were acquired. Subsequently, angular (AD) and linear deviation (LD) values were calculated. LD was further examined separately along the x, y, and z axes. Data were statistically analyzed.

Results: According to the results of one-way ANOVAs, significant differences were detected among color groups on AD, LD, RMS estimate error, ∆x, ∆y, and ∆z data. The lowest AD and LD values were exhibited by the SAGREY group in all implant sites. The SAGREY group was followed by the SABEIGE, SAWHITE, SARED, and SABLUE groups.

Conclusions: The SAGREY outperformed the other groups in terms of trueness. Although the LD values of all color groups were below the threshold value (<100 µm), only the AD values of the SAGREY, SABEIGE, and SAWHITE groups were clinically acceptable (<0.5°).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.90
自引率
15.00%
发文量
171
审稿时长
6-12 weeks
期刊介绍: The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信