稳定剂对长期检测加标口服液中猪甲型流感病毒 (swIAV) 的影响。

IF 3 2区 农林科学 Q1 VETERINARY SCIENCES
K Grau, K Lillie-Jaschniski, A Graaf-Rau, T Harder, M Eddicks, S Zöls, Y Zablotski, M Ritzmann, J Stadler
{"title":"稳定剂对长期检测加标口服液中猪甲型流感病毒 (swIAV) 的影响。","authors":"K Grau, K Lillie-Jaschniski, A Graaf-Rau, T Harder, M Eddicks, S Zöls, Y Zablotski, M Ritzmann, J Stadler","doi":"10.1186/s40813-024-00386-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Aggregated samples such as oral fluids (OFs) display an animal friendly and time and cost-efficient sample type for swine Influenza A virus (swIAV) monitoring. However, further molecular and biological characterization of swIAV is of particular significance. The reportedly inferior suitability of aggregated samples for subtyping of swIAV presents a major drawback compared to nasal swabs, still considered the most appropriate sample type for this purpose (Garrido-Mantilla et al. BMC Vet Res 15(1):61, 2019). In addition, the viral load in the original sample, storage conditions and characteristics of different swIAV strains might further compromise the eligibility of aggregated samples for molecular detection and subtyping. Therefore, the present study aimed to evaluate the suitability of stabilizing media to minimize the degradation of viral RNA and thus increase the detection and subtyping rate of swIAV by RT-qPCR in spiked OFs under different conditions (virus strain, storage temperature and viral load in the original sample) over a time span of 14 days.</p><p><strong>Results: </strong>The use of stabilizing media in spiked OFs resulted in a significant higher probability to detect swIAV RNA compared to OFs without stabilizers (OR = 46.1, p < 0.001). In addition, swIAV degradation over time was significantly reduced in samples suspended with stabilizer (OR = 5.80, p < 0.001), in samples stored at 4 °C (OR = 2.53, p < 0.001) and in samples spiked with the avian derived H1N2 subtype (OR = 2.26, p < 0.01). No significant differences in swIAV RNA detection and degradation of swIAV RNA in spiked OFs over time were observed between the three different stabilizing media.</p><p><strong>Conclusion: </strong>Addition of stabilizers and storage of samples under cooled conditions significantly improved detection and subtyping of swIAV in spiked OFs.</p>","PeriodicalId":20352,"journal":{"name":"Porcine Health Management","volume":"10 1","pages":"49"},"PeriodicalIF":3.0000,"publicationDate":"2024-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11552184/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effect of stabilizers on the detection of swine influenza A virus (swIAV) in spiked oral fluids over time.\",\"authors\":\"K Grau, K Lillie-Jaschniski, A Graaf-Rau, T Harder, M Eddicks, S Zöls, Y Zablotski, M Ritzmann, J Stadler\",\"doi\":\"10.1186/s40813-024-00386-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Aggregated samples such as oral fluids (OFs) display an animal friendly and time and cost-efficient sample type for swine Influenza A virus (swIAV) monitoring. However, further molecular and biological characterization of swIAV is of particular significance. The reportedly inferior suitability of aggregated samples for subtyping of swIAV presents a major drawback compared to nasal swabs, still considered the most appropriate sample type for this purpose (Garrido-Mantilla et al. BMC Vet Res 15(1):61, 2019). In addition, the viral load in the original sample, storage conditions and characteristics of different swIAV strains might further compromise the eligibility of aggregated samples for molecular detection and subtyping. Therefore, the present study aimed to evaluate the suitability of stabilizing media to minimize the degradation of viral RNA and thus increase the detection and subtyping rate of swIAV by RT-qPCR in spiked OFs under different conditions (virus strain, storage temperature and viral load in the original sample) over a time span of 14 days.</p><p><strong>Results: </strong>The use of stabilizing media in spiked OFs resulted in a significant higher probability to detect swIAV RNA compared to OFs without stabilizers (OR = 46.1, p < 0.001). In addition, swIAV degradation over time was significantly reduced in samples suspended with stabilizer (OR = 5.80, p < 0.001), in samples stored at 4 °C (OR = 2.53, p < 0.001) and in samples spiked with the avian derived H1N2 subtype (OR = 2.26, p < 0.01). No significant differences in swIAV RNA detection and degradation of swIAV RNA in spiked OFs over time were observed between the three different stabilizing media.</p><p><strong>Conclusion: </strong>Addition of stabilizers and storage of samples under cooled conditions significantly improved detection and subtyping of swIAV in spiked OFs.</p>\",\"PeriodicalId\":20352,\"journal\":{\"name\":\"Porcine Health Management\",\"volume\":\"10 1\",\"pages\":\"49\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11552184/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Porcine Health Management\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1186/s40813-024-00386-6\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Porcine Health Management","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1186/s40813-024-00386-6","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

背景:在监测猪甲型流感病毒(swIAV)时,口腔液(OFs)等聚集样本是一种对动物友好、省时、省钱的样本类型。然而,对猪甲型流感病毒进行进一步的分子和生物学鉴定具有特别重要的意义。据报道,与鼻拭子相比,聚集样本在猪甲型流感病毒亚型鉴定方面的适用性较差,这是其主要缺点,而鼻拭子仍被认为是最合适的样本类型(Garrido-Mantilla 等人,BMC Vet Res 15(1):61, 2019)。此外,原始样本中的病毒载量、储存条件和不同 swIAV 株系的特征可能会进一步影响聚合样本进行分子检测和亚型鉴定的资格。因此,本研究旨在评估稳定培养基的适用性,以最大限度地减少病毒 RNA 的降解,从而在 14 天的时间跨度内,在不同条件(病毒株、储存温度和原始样本中的病毒载量)下,通过 RT-qPCR 提高加标 OF 中 swIAV 的检测率和亚型鉴定率:结果:与未添加稳定剂的 OFs 相比,添加稳定剂的 OFs 检测到 swIAV RNA 的几率明显更高(OR = 46.1,p 结论:添加稳定剂和添加稳定剂的 OFs 检测到 swIAV RNA 的几率明显高于未添加稳定剂的 OFs:添加稳定剂并在冷却条件下储存样品可显著提高加标 OF 中 swIAV 的检测率和亚型鉴定率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of stabilizers on the detection of swine influenza A virus (swIAV) in spiked oral fluids over time.

Background: Aggregated samples such as oral fluids (OFs) display an animal friendly and time and cost-efficient sample type for swine Influenza A virus (swIAV) monitoring. However, further molecular and biological characterization of swIAV is of particular significance. The reportedly inferior suitability of aggregated samples for subtyping of swIAV presents a major drawback compared to nasal swabs, still considered the most appropriate sample type for this purpose (Garrido-Mantilla et al. BMC Vet Res 15(1):61, 2019). In addition, the viral load in the original sample, storage conditions and characteristics of different swIAV strains might further compromise the eligibility of aggregated samples for molecular detection and subtyping. Therefore, the present study aimed to evaluate the suitability of stabilizing media to minimize the degradation of viral RNA and thus increase the detection and subtyping rate of swIAV by RT-qPCR in spiked OFs under different conditions (virus strain, storage temperature and viral load in the original sample) over a time span of 14 days.

Results: The use of stabilizing media in spiked OFs resulted in a significant higher probability to detect swIAV RNA compared to OFs without stabilizers (OR = 46.1, p < 0.001). In addition, swIAV degradation over time was significantly reduced in samples suspended with stabilizer (OR = 5.80, p < 0.001), in samples stored at 4 °C (OR = 2.53, p < 0.001) and in samples spiked with the avian derived H1N2 subtype (OR = 2.26, p < 0.01). No significant differences in swIAV RNA detection and degradation of swIAV RNA in spiked OFs over time were observed between the three different stabilizing media.

Conclusion: Addition of stabilizers and storage of samples under cooled conditions significantly improved detection and subtyping of swIAV in spiked OFs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Porcine Health Management
Porcine Health Management Veterinary-Food Animals
CiteScore
5.40
自引率
5.90%
发文量
49
审稿时长
14 weeks
期刊介绍: Porcine Health Management (PHM) is an open access peer-reviewed journal that aims to publish relevant, novel and revised information regarding all aspects of swine health medicine and production.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信