代理甲卡因对 6 至 7 岁白种人体内环戊丙酸动态变化的影响。

IF 2.8 3区 医学 Q1 OPHTHALMOLOGY
Megan Doyle, Veronica O'Dwyer, Síofra Harrington
{"title":"代理甲卡因对 6 至 7 岁白种人体内环戊丙酸动态变化的影响。","authors":"Megan Doyle, Veronica O'Dwyer, Síofra Harrington","doi":"10.1111/opo.13421","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study compared the efficacy of cyclopentolate hydrochloride at 10-, 20- and 30-min post-instillation in White 6- to 7-year-olds, with and without prior instillation of proxymetacaine hydrochloride. The primary aim was to determine if accurate autorefraction values can be obtained sooner than the current standard of 30-min post-cycloplegia. The secondary aim was to investigate whether proxymetacaine hydrochloride enhances the efficiency of cyclopentolate.</p><p><strong>Methods: </strong>Participants were 112 White 6- to 7-year-olds from the Child Eye Health Study. The right eye received 0.5% proxymetacaine hydrochloride and 1.0% cyclopentolate hydrochloride, and the left eye received only 1.0% cyclopentolate hydrochloride. Non-cycloplegic and cycloplegic refractive error (at 0, 10, 20 and 30 min) was measured using a binocular, open-field autorefractometer. Data were analysed through paired t-tests, concordance analysis, linear regression, equivalence testing and Bland-Altman analysis, using the 95% limits of agreement.</p><p><strong>Results: </strong>Mean spherical equivalent refraction (SER) (SD) in the right eye at 0-, 10-, 20- and 30-min post-instillation was 0.62 (1.45) D, 1.52 (1.80) D, 1.64 (1.81) D and 1.72 (1.80) D, respectively. Mean left eye SER (SD) were 0.68 (1.24) D, 1.42 (1.66) D, 1.56 (1.66) D and 1.68 (1.72) D, respectively. Bland-Altman analysis showed a high level of agreement, and equivalence testing confirmed that there was no clinically significant difference in SER at 20 and 30 min in both eyes (within ±0.50 D), with mean differences of 0.08 (0.23) D in the right eye and 0.13 (0.30) D in the left eye (p = 0.21). However, SER at 10 and 30 min were equivalent in the right eye only.</p><p><strong>Conclusions: </strong>Accurate autorefraction values can be obtained 20-min post-instillation of 1.0% cyclopentolate in white children aged 6-7 years, potentially reducing clinical testing times. Proxymetacaine pre-instillation allows for reliable measurements as early as 10-min post-instillation of cyclopentolate. Further research is needed to validate these findings in non-White populations and to determine the safe discharge time post-proxymetacaine instillation.</p>","PeriodicalId":19522,"journal":{"name":"Ophthalmic and Physiological Optics","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact of proxymetacaine on the dynamics of cyclopentolate in White 6- to 7-year-olds.\",\"authors\":\"Megan Doyle, Veronica O'Dwyer, Síofra Harrington\",\"doi\":\"10.1111/opo.13421\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study compared the efficacy of cyclopentolate hydrochloride at 10-, 20- and 30-min post-instillation in White 6- to 7-year-olds, with and without prior instillation of proxymetacaine hydrochloride. The primary aim was to determine if accurate autorefraction values can be obtained sooner than the current standard of 30-min post-cycloplegia. The secondary aim was to investigate whether proxymetacaine hydrochloride enhances the efficiency of cyclopentolate.</p><p><strong>Methods: </strong>Participants were 112 White 6- to 7-year-olds from the Child Eye Health Study. The right eye received 0.5% proxymetacaine hydrochloride and 1.0% cyclopentolate hydrochloride, and the left eye received only 1.0% cyclopentolate hydrochloride. Non-cycloplegic and cycloplegic refractive error (at 0, 10, 20 and 30 min) was measured using a binocular, open-field autorefractometer. Data were analysed through paired t-tests, concordance analysis, linear regression, equivalence testing and Bland-Altman analysis, using the 95% limits of agreement.</p><p><strong>Results: </strong>Mean spherical equivalent refraction (SER) (SD) in the right eye at 0-, 10-, 20- and 30-min post-instillation was 0.62 (1.45) D, 1.52 (1.80) D, 1.64 (1.81) D and 1.72 (1.80) D, respectively. Mean left eye SER (SD) were 0.68 (1.24) D, 1.42 (1.66) D, 1.56 (1.66) D and 1.68 (1.72) D, respectively. Bland-Altman analysis showed a high level of agreement, and equivalence testing confirmed that there was no clinically significant difference in SER at 20 and 30 min in both eyes (within ±0.50 D), with mean differences of 0.08 (0.23) D in the right eye and 0.13 (0.30) D in the left eye (p = 0.21). However, SER at 10 and 30 min were equivalent in the right eye only.</p><p><strong>Conclusions: </strong>Accurate autorefraction values can be obtained 20-min post-instillation of 1.0% cyclopentolate in white children aged 6-7 years, potentially reducing clinical testing times. Proxymetacaine pre-instillation allows for reliable measurements as early as 10-min post-instillation of cyclopentolate. Further research is needed to validate these findings in non-White populations and to determine the safe discharge time post-proxymetacaine instillation.</p>\",\"PeriodicalId\":19522,\"journal\":{\"name\":\"Ophthalmic and Physiological Optics\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-11-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmic and Physiological Optics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/opo.13421\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic and Physiological Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/opo.13421","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究比较了盐酸环戊丙酸在 6 至 7 岁白种人中灌注后 10 分钟、20 分钟和 30 分钟的疗效,以及事先灌注和未灌注盐酸丙美卡因的疗效。主要目的是确定是否能比目前的环麻后 30 分钟标准更快获得准确的自动屈光度值。次要目的是研究盐酸丙美卡因是否能提高环戊丙酸的效率:参与者是儿童眼健康研究中的 112 名 6 至 7 岁的白人儿童。右眼接受 0.5% 的盐酸丙美卡因和 1.0% 的盐酸环戊丙酸,左眼只接受 1.0% 的盐酸环戊丙酸。使用双目开视野自动屈光仪测量非环视和环视屈光不正(0、10、20 和 30 分钟)。通过配对 t 检验、一致性分析、线性回归、等效检验和布兰-阿尔特曼分析(使用 95% 的一致性限值)对数据进行分析:右眼在晶体植入后 0、10、20 和 30 分钟的平均球面等效屈光度(SER)(标清)分别为 0.62 (1.45) D、1.52 (1.80) D、1.64 (1.81) D 和 1.72 (1.80) D。左眼平均 SER(标清)分别为 0.68 (1.24) D、1.42 (1.66) D、1.56 (1.66) D 和 1.68 (1.72) D。Bland-Altman分析表明两者的一致性很高,等效测试证实,双眼在20分钟和30分钟时的SER没有明显的临床差异(±0.50 D以内),右眼的平均差异为0.08 (0.23) D,左眼的平均差异为0.13 (0.30) D (p = 0.21)。然而,仅右眼在 10 分钟和 30 分钟时的 SER 相等:结论:在 6-7 岁的白种儿童中,1.0% 环戊托品植入后 20 分钟即可获得准确的自动屈光度值,从而有可能缩短临床测试时间。在环戊托品植入前使用丙美卡因可在植入后 10 分钟内获得可靠的测量值。要在非白人群体中验证这些研究结果,并确定灌注丙美卡因后的安全出院时间,还需要进一步的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of proxymetacaine on the dynamics of cyclopentolate in White 6- to 7-year-olds.

Purpose: This study compared the efficacy of cyclopentolate hydrochloride at 10-, 20- and 30-min post-instillation in White 6- to 7-year-olds, with and without prior instillation of proxymetacaine hydrochloride. The primary aim was to determine if accurate autorefraction values can be obtained sooner than the current standard of 30-min post-cycloplegia. The secondary aim was to investigate whether proxymetacaine hydrochloride enhances the efficiency of cyclopentolate.

Methods: Participants were 112 White 6- to 7-year-olds from the Child Eye Health Study. The right eye received 0.5% proxymetacaine hydrochloride and 1.0% cyclopentolate hydrochloride, and the left eye received only 1.0% cyclopentolate hydrochloride. Non-cycloplegic and cycloplegic refractive error (at 0, 10, 20 and 30 min) was measured using a binocular, open-field autorefractometer. Data were analysed through paired t-tests, concordance analysis, linear regression, equivalence testing and Bland-Altman analysis, using the 95% limits of agreement.

Results: Mean spherical equivalent refraction (SER) (SD) in the right eye at 0-, 10-, 20- and 30-min post-instillation was 0.62 (1.45) D, 1.52 (1.80) D, 1.64 (1.81) D and 1.72 (1.80) D, respectively. Mean left eye SER (SD) were 0.68 (1.24) D, 1.42 (1.66) D, 1.56 (1.66) D and 1.68 (1.72) D, respectively. Bland-Altman analysis showed a high level of agreement, and equivalence testing confirmed that there was no clinically significant difference in SER at 20 and 30 min in both eyes (within ±0.50 D), with mean differences of 0.08 (0.23) D in the right eye and 0.13 (0.30) D in the left eye (p = 0.21). However, SER at 10 and 30 min were equivalent in the right eye only.

Conclusions: Accurate autorefraction values can be obtained 20-min post-instillation of 1.0% cyclopentolate in white children aged 6-7 years, potentially reducing clinical testing times. Proxymetacaine pre-instillation allows for reliable measurements as early as 10-min post-instillation of cyclopentolate. Further research is needed to validate these findings in non-White populations and to determine the safe discharge time post-proxymetacaine instillation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
13.80%
发文量
135
审稿时长
6-12 weeks
期刊介绍: Ophthalmic & Physiological Optics, first published in 1925, is a leading international interdisciplinary journal that addresses basic and applied questions pertinent to contemporary research in vision science and optometry. OPO publishes original research papers, technical notes, reviews and letters and will interest researchers, educators and clinicians concerned with the development, use and restoration of vision.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信