{"title":"使用马氏瓣治疗单切口微型吊带术后的拴系阴道综合征。","authors":"Mahmut Kuntay Kokanalı, Melike Doganay","doi":"10.1007/s00192-024-05979-x","DOIUrl":null,"url":null,"abstract":"<p><p>Tethered vagina syndrome is an iatrogenic, but poorly defined condition that usually develops after surgical procedures performed on the anterior vaginal wall. Loss of elasticity as a result of scarring in the bladder neck-urethra is blamed for its pathogenesis. Patients often present with typical, massive uncontrollable urine loss and have specific examination findings. Having awareness about the diagnosis is important for its management. Surgical restoration and maintenance of bladder neck elasticity are essential for treatment. In our case, we presented the surgical approach we applied to tethered vagina syndrome that developed after the single-incision mini-sling operation. We demonstrated the surgical technique of Martius flap transposition and showed that this flap can be used to maintain the elasticity of the bladder neck area of the vagina.</p>","PeriodicalId":14355,"journal":{"name":"International Urogynecology Journal","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of the Martius Flap for Tethered Vagina Syndrome After a Single-Incision Mini-Sling Procedure.\",\"authors\":\"Mahmut Kuntay Kokanalı, Melike Doganay\",\"doi\":\"10.1007/s00192-024-05979-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Tethered vagina syndrome is an iatrogenic, but poorly defined condition that usually develops after surgical procedures performed on the anterior vaginal wall. Loss of elasticity as a result of scarring in the bladder neck-urethra is blamed for its pathogenesis. Patients often present with typical, massive uncontrollable urine loss and have specific examination findings. Having awareness about the diagnosis is important for its management. Surgical restoration and maintenance of bladder neck elasticity are essential for treatment. In our case, we presented the surgical approach we applied to tethered vagina syndrome that developed after the single-incision mini-sling operation. We demonstrated the surgical technique of Martius flap transposition and showed that this flap can be used to maintain the elasticity of the bladder neck area of the vagina.</p>\",\"PeriodicalId\":14355,\"journal\":{\"name\":\"International Urogynecology Journal\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Urogynecology Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00192-024-05979-x\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OBSTETRICS & GYNECOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Urogynecology Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00192-024-05979-x","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
Use of the Martius Flap for Tethered Vagina Syndrome After a Single-Incision Mini-Sling Procedure.
Tethered vagina syndrome is an iatrogenic, but poorly defined condition that usually develops after surgical procedures performed on the anterior vaginal wall. Loss of elasticity as a result of scarring in the bladder neck-urethra is blamed for its pathogenesis. Patients often present with typical, massive uncontrollable urine loss and have specific examination findings. Having awareness about the diagnosis is important for its management. Surgical restoration and maintenance of bladder neck elasticity are essential for treatment. In our case, we presented the surgical approach we applied to tethered vagina syndrome that developed after the single-incision mini-sling operation. We demonstrated the surgical technique of Martius flap transposition and showed that this flap can be used to maintain the elasticity of the bladder neck area of the vagina.
期刊介绍:
The International Urogynecology Journal is the official journal of the International Urogynecological Association (IUGA).The International Urogynecology Journal has evolved in response to a perceived need amongst the clinicians, scientists, and researchers active in the field of urogynecology and pelvic floor disorders. Gynecologists, urologists, physiotherapists, nurses and basic scientists require regular means of communication within this field of pelvic floor dysfunction to express new ideas and research, and to review clinical practice in the diagnosis and treatment of women with disorders of the pelvic floor. This Journal has adopted the peer review process for all original contributions and will maintain high standards with regard to the research published therein. The clinical approach to urogynecology and pelvic floor disorders will be emphasized with each issue containing clinically relevant material that will be immediately applicable for clinical medicine. This publication covers all aspects of the field in an interdisciplinary fashion