两种增强型单焦点眼内透镜 3 个月临床疗效的比较:单中心前瞻性研究。

IF 1.4 4区 医学 Q3 OPHTHALMOLOGY
Vito Spagnuolo, Giulio Vicini, Ginevra Marincolo, Alessandro Franchini, Fabrizio Giansanti, Cinzia Mazzini
{"title":"两种增强型单焦点眼内透镜 3 个月临床疗效的比较:单中心前瞻性研究。","authors":"Vito Spagnuolo, Giulio Vicini, Ginevra Marincolo, Alessandro Franchini, Fabrizio Giansanti, Cinzia Mazzini","doi":"10.1177/11206721241298031","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aims to compare the 3-month clinical outcomes between two enhanced monofocal intraocular lenses (IOLs) following cataract surgery.Setting: Eye Clinic of Careggi University Hospital, Florence, Italy.</p><p><strong>Design: </strong>Single-center prospective study.</p><p><strong>Methods: </strong>We included patients with cataract and corneal astigmatism less than 0.75 D, with no ocular comorbidities, who underwent unilateral cataract surgery with implantation of either the Tecnis Eyhance ICB00 (<i>N</i> = 25) or Evolux (<i>N</i> = 25) IOLs. Standard cataract procedures were performed without complications. The main outcome measures included uncorrected and corrected visual acuity at distance (4 m), intermediate (60 cm) and near (40 cm) at 3-month follow-up. Additionally, monocular defocus curves, aberrometric profiles, and perceptions of halo and glare were evaluated.</p><p><strong>Results: </strong>The study involved 50 patients (26 male, 24 female) with a mean age of 68 ± 8 years. Preoperative characteristics were similar between the groups, and no intraoperative or postoperative complications were reported. Statistically significant differences were observed between the groups, with the Evolux IOL showing superior results (<i>p</i> < 0.05) in terms of uncorrected and corrected visual acuity at near, intermediate, and distance, as well as in aberrometric profiles (lower-order aberration root-mean-square [RMS], higher-order aberration RMS, spherical equivalent RMS, and point spread function) and defocus curves.</p><p><strong>Conclusions: </strong>Based on our experience, while both IOLs offer substantial visual performance for intermediate and distance vision, the Evolux IOL demonstrated superior mean visual outcomes and objective parameters at the 3-month follow-up compared to the Tecnis Eyhance IOL. This indicates a potential advantage of the Evolux IOL in providing better visual performance.</p>","PeriodicalId":12000,"journal":{"name":"European Journal of Ophthalmology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of 3-month clinical outcomes between two enhanced monofocal intraocular lenses: A single-center prospective study.\",\"authors\":\"Vito Spagnuolo, Giulio Vicini, Ginevra Marincolo, Alessandro Franchini, Fabrizio Giansanti, Cinzia Mazzini\",\"doi\":\"10.1177/11206721241298031\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aims to compare the 3-month clinical outcomes between two enhanced monofocal intraocular lenses (IOLs) following cataract surgery.Setting: Eye Clinic of Careggi University Hospital, Florence, Italy.</p><p><strong>Design: </strong>Single-center prospective study.</p><p><strong>Methods: </strong>We included patients with cataract and corneal astigmatism less than 0.75 D, with no ocular comorbidities, who underwent unilateral cataract surgery with implantation of either the Tecnis Eyhance ICB00 (<i>N</i> = 25) or Evolux (<i>N</i> = 25) IOLs. Standard cataract procedures were performed without complications. The main outcome measures included uncorrected and corrected visual acuity at distance (4 m), intermediate (60 cm) and near (40 cm) at 3-month follow-up. Additionally, monocular defocus curves, aberrometric profiles, and perceptions of halo and glare were evaluated.</p><p><strong>Results: </strong>The study involved 50 patients (26 male, 24 female) with a mean age of 68 ± 8 years. Preoperative characteristics were similar between the groups, and no intraoperative or postoperative complications were reported. Statistically significant differences were observed between the groups, with the Evolux IOL showing superior results (<i>p</i> < 0.05) in terms of uncorrected and corrected visual acuity at near, intermediate, and distance, as well as in aberrometric profiles (lower-order aberration root-mean-square [RMS], higher-order aberration RMS, spherical equivalent RMS, and point spread function) and defocus curves.</p><p><strong>Conclusions: </strong>Based on our experience, while both IOLs offer substantial visual performance for intermediate and distance vision, the Evolux IOL demonstrated superior mean visual outcomes and objective parameters at the 3-month follow-up compared to the Tecnis Eyhance IOL. This indicates a potential advantage of the Evolux IOL in providing better visual performance.</p>\",\"PeriodicalId\":12000,\"journal\":{\"name\":\"European Journal of Ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/11206721241298031\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11206721241298031","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在比较两种增强型单焦点人工晶体(IOL)在白内障手术后 3 个月的临床疗效:地点:意大利佛罗伦萨卡雷吉大学医院眼科诊所:设计:单中心前瞻性研究:研究对象为白内障患者,角膜散光小于 0.75 D,无眼部合并症,接受单侧白内障手术并植入 Tecnis Eyhance ICB00(25 例)或 Evolux(25 例)人工晶体。标准白内障手术无并发症。主要结果指标包括随访 3 个月时远距离(4 米)、中距离(60 厘米)和近距离(40 厘米)的未矫正视力和矫正视力。此外,还评估了单眼离焦曲线、像差曲线以及对光晕和眩光的感觉:研究涉及 50 名患者(26 名男性,24 名女性),平均年龄为 68 ± 8 岁。两组患者的术前特征相似,无术中或术后并发症报告。从统计学角度看,两组之间存在明显差异,Evolux IOL 的疗效更好(p 结论:Evolux IOL 和 Evolux IOL 的疗效都更好:根据我们的经验,虽然两种人工晶体都能提供良好的中远距离视觉效果,但与 Tecnis Eyhance 人工晶体相比,Evolux 人工晶体在 3 个月的随访中显示出更佳的平均视觉效果和客观参数。这表明 Evolux 人工晶体在提供更好的视觉效果方面具有潜在优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of 3-month clinical outcomes between two enhanced monofocal intraocular lenses: A single-center prospective study.

Purpose: This study aims to compare the 3-month clinical outcomes between two enhanced monofocal intraocular lenses (IOLs) following cataract surgery.Setting: Eye Clinic of Careggi University Hospital, Florence, Italy.

Design: Single-center prospective study.

Methods: We included patients with cataract and corneal astigmatism less than 0.75 D, with no ocular comorbidities, who underwent unilateral cataract surgery with implantation of either the Tecnis Eyhance ICB00 (N = 25) or Evolux (N = 25) IOLs. Standard cataract procedures were performed without complications. The main outcome measures included uncorrected and corrected visual acuity at distance (4 m), intermediate (60 cm) and near (40 cm) at 3-month follow-up. Additionally, monocular defocus curves, aberrometric profiles, and perceptions of halo and glare were evaluated.

Results: The study involved 50 patients (26 male, 24 female) with a mean age of 68 ± 8 years. Preoperative characteristics were similar between the groups, and no intraoperative or postoperative complications were reported. Statistically significant differences were observed between the groups, with the Evolux IOL showing superior results (p < 0.05) in terms of uncorrected and corrected visual acuity at near, intermediate, and distance, as well as in aberrometric profiles (lower-order aberration root-mean-square [RMS], higher-order aberration RMS, spherical equivalent RMS, and point spread function) and defocus curves.

Conclusions: Based on our experience, while both IOLs offer substantial visual performance for intermediate and distance vision, the Evolux IOL demonstrated superior mean visual outcomes and objective parameters at the 3-month follow-up compared to the Tecnis Eyhance IOL. This indicates a potential advantage of the Evolux IOL in providing better visual performance.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.60
自引率
0.00%
发文量
372
审稿时长
3-8 weeks
期刊介绍: The European Journal of Ophthalmology was founded in 1991 and is issued in print bi-monthly. It publishes only peer-reviewed original research reporting clinical observations and laboratory investigations with clinical relevance focusing on new diagnostic and surgical techniques, instrument and therapy updates, results of clinical trials and research findings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信