{"title":"离子选择性迁移率差分放大器:增强水凝胶中的压力诱导电压响应","authors":"Kai Yang, Bolong Li, Zhihao Ma, Jiangang Xu, Dong Wang, Zhiheng Zeng, Derek Ho","doi":"10.1002/anie.202415000","DOIUrl":null,"url":null,"abstract":"<p><p>Piezoionics is an emerging mechanical-electrical energy conversion paradigm that enables self-powered sensing systems for next-generation intelligent wearable electronics. However, there are currently no rational design approaches to enhance the stimulus response of piezoionic devices. Here, we present a strategy using crown ether as ion-selective mobility differential amplifiers for enhancing the pressured-induced voltage response in ionic polyvinyl alcohol (PVA) hydrogels. The crown ether grafted PVA (PVA-CE) hydrogel prototype achieves a 30-fold amplified piezoionic coefficient of 1490 nV Pa-1 within 0 - 1 kPa, compared to 49 nV Pa-1 of the unmodified PVA. The PVA-CE exhibits an ultra-low pressure detection limit of 0.2 Pa with a fast response time of 18.1 ms. Leveraging these properties, we further demonstrate a human somatosensory network analogous PVA-CE piezoionic skin using arrayed pressure sensing. These capabilities hold great promise for emerging healthcare applications such as synthetic biology, soft robotics, and beyond.</p>","PeriodicalId":125,"journal":{"name":"Angewandte Chemie International Edition","volume":" ","pages":"e202415000"},"PeriodicalIF":16.1000,"publicationDate":"2024-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ion-Selective Mobility Differential Amplifier: Enhancing Pressure-Induced Voltage Response in Hydrogels.\",\"authors\":\"Kai Yang, Bolong Li, Zhihao Ma, Jiangang Xu, Dong Wang, Zhiheng Zeng, Derek Ho\",\"doi\":\"10.1002/anie.202415000\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Piezoionics is an emerging mechanical-electrical energy conversion paradigm that enables self-powered sensing systems for next-generation intelligent wearable electronics. However, there are currently no rational design approaches to enhance the stimulus response of piezoionic devices. Here, we present a strategy using crown ether as ion-selective mobility differential amplifiers for enhancing the pressured-induced voltage response in ionic polyvinyl alcohol (PVA) hydrogels. The crown ether grafted PVA (PVA-CE) hydrogel prototype achieves a 30-fold amplified piezoionic coefficient of 1490 nV Pa-1 within 0 - 1 kPa, compared to 49 nV Pa-1 of the unmodified PVA. The PVA-CE exhibits an ultra-low pressure detection limit of 0.2 Pa with a fast response time of 18.1 ms. Leveraging these properties, we further demonstrate a human somatosensory network analogous PVA-CE piezoionic skin using arrayed pressure sensing. These capabilities hold great promise for emerging healthcare applications such as synthetic biology, soft robotics, and beyond.</p>\",\"PeriodicalId\":125,\"journal\":{\"name\":\"Angewandte Chemie International Edition\",\"volume\":\" \",\"pages\":\"e202415000\"},\"PeriodicalIF\":16.1000,\"publicationDate\":\"2024-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Angewandte Chemie International Edition\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1002/anie.202415000\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Angewandte Chemie International Edition","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1002/anie.202415000","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

压电技术是一种新兴的机械电能转换模式,可为下一代智能可穿戴电子设备提供自供电传感系统。然而,目前还没有合理的设计方法来增强压电器件的刺激响应。在此,我们提出了一种利用冠醚作为离子选择性迁移率差分放大器的策略,以增强离子聚乙烯醇(PVA)水凝胶的压力诱导电压响应。与未改性 PVA 的 49 nV Pa-1 相比,冠醚接枝 PVA(PVA-CE)水凝胶原型在 0 - 1 kPa 范围内的压电系数放大了 30 倍,达到 1490 nV Pa-1。PVA-CE 的超低压力检测限为 0.2 Pa,快速响应时间为 18.1 ms。利用这些特性,我们使用阵列压力传感技术进一步展示了类似于 PVA-CE 压电皮肤的人类体感网络。这些功能为合成生物学、软机器人等新兴医疗保健应用带来了巨大前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ion-Selective Mobility Differential Amplifier: Enhancing Pressure-Induced Voltage Response in Hydrogels.

Piezoionics is an emerging mechanical-electrical energy conversion paradigm that enables self-powered sensing systems for next-generation intelligent wearable electronics. However, there are currently no rational design approaches to enhance the stimulus response of piezoionic devices. Here, we present a strategy using crown ether as ion-selective mobility differential amplifiers for enhancing the pressured-induced voltage response in ionic polyvinyl alcohol (PVA) hydrogels. The crown ether grafted PVA (PVA-CE) hydrogel prototype achieves a 30-fold amplified piezoionic coefficient of 1490 nV Pa-1 within 0 - 1 kPa, compared to 49 nV Pa-1 of the unmodified PVA. The PVA-CE exhibits an ultra-low pressure detection limit of 0.2 Pa with a fast response time of 18.1 ms. Leveraging these properties, we further demonstrate a human somatosensory network analogous PVA-CE piezoionic skin using arrayed pressure sensing. These capabilities hold great promise for emerging healthcare applications such as synthetic biology, soft robotics, and beyond.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
26.60
自引率
6.60%
发文量
3549
审稿时长
1.5 months
期刊介绍: Angewandte Chemie, a journal of the German Chemical Society (GDCh), maintains a leading position among scholarly journals in general chemistry with an impressive Impact Factor of 16.6 (2022 Journal Citation Reports, Clarivate, 2023). Published weekly in a reader-friendly format, it features new articles almost every day. Established in 1887, Angewandte Chemie is a prominent chemistry journal, offering a dynamic blend of Review-type articles, Highlights, Communications, and Research Articles on a weekly basis, making it unique in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信