一种由 CNT-COOH 电极上的两性共聚物组成的抗生物污染电化学传感器,用于对手术患者的异丙酚血药浓度进行床旁监测

IF 8 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Shan Wang , Chunguang Kuai , Qianwen He , Feng He , Bingrui Xiong , Li Li , Xue Ke , Yuzheng Guo , Mian Peng
{"title":"一种由 CNT-COOH 电极上的两性共聚物组成的抗生物污染电化学传感器,用于对手术患者的异丙酚血药浓度进行床旁监测","authors":"Shan Wang ,&nbsp;Chunguang Kuai ,&nbsp;Qianwen He ,&nbsp;Feng He ,&nbsp;Bingrui Xiong ,&nbsp;Li Li ,&nbsp;Xue Ke ,&nbsp;Yuzheng Guo ,&nbsp;Mian Peng","doi":"10.1016/j.snb.2024.136890","DOIUrl":null,"url":null,"abstract":"<div><div>The monitoring of propofol (PPF) blood concentration is vital for the safety of intravenous anesthesia. Electrochemical sensors represent a powerful tool for the detection of PPF. Our previous research has demonstrated that CNT-COOH electrodes exhibit advantages in resisting electrochemical fouling from PPF oxidation products. Nevertheless, biofouling remains a critical challenge hindering the clinical transformation of PPF electrochemical sensors. To address this issue, we employed in-situ electrodeposition to deposit zwitterionic sulfobetaine methacrylate (SBMA) and overoxidation polydopamine (OPDA) onto CNT-COOH screen-printed electrodes (SPEs) and proposed an innovative CNT-COOH/OPDA-SBMA (CNT-COOH/OPS) amphiphilic antifouling biosensor. This amphiphilic electrode, featuring both hydrophilic and hydrophobic properties, demonstrated excellent antifouling performance through electrochemical characterization in ex-vivo blood assays, coupled with commendable sensitivity, stability, and selectivity. CNT-COOH/OPS SPEs were also applied in point-of-care monitoring of the PPF blood concentrations in animals and clinical surgical patients and exhibited good accuracy and linearity (Ipa=0.0084c+0.4458, R<sup>2</sup>=0.995) with a limit of detection of 2.948 μM. Further, the electrodes demonstrated a high recovery and the blood concentrations determined by electrochemical detection had robust negative correlation with the depth of anesthesia. Therefore, CNT-COOH/OPS SPEs hold promise as a significant tool in point-of-care monitoring of PPF, offering patients safer and more personalized medical care.</div></div>","PeriodicalId":425,"journal":{"name":"Sensors and Actuators B: Chemical","volume":"424 ","pages":"Article 136890"},"PeriodicalIF":8.0000,"publicationDate":"2024-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An antibiofouling electrochemical sensor consisting of amphiphilic copolymer on CNT-COOH electrodes for point-of-care monitoring of propofol blood concentration in surgical patients\",\"authors\":\"Shan Wang ,&nbsp;Chunguang Kuai ,&nbsp;Qianwen He ,&nbsp;Feng He ,&nbsp;Bingrui Xiong ,&nbsp;Li Li ,&nbsp;Xue Ke ,&nbsp;Yuzheng Guo ,&nbsp;Mian Peng\",\"doi\":\"10.1016/j.snb.2024.136890\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The monitoring of propofol (PPF) blood concentration is vital for the safety of intravenous anesthesia. Electrochemical sensors represent a powerful tool for the detection of PPF. Our previous research has demonstrated that CNT-COOH electrodes exhibit advantages in resisting electrochemical fouling from PPF oxidation products. Nevertheless, biofouling remains a critical challenge hindering the clinical transformation of PPF electrochemical sensors. To address this issue, we employed in-situ electrodeposition to deposit zwitterionic sulfobetaine methacrylate (SBMA) and overoxidation polydopamine (OPDA) onto CNT-COOH screen-printed electrodes (SPEs) and proposed an innovative CNT-COOH/OPDA-SBMA (CNT-COOH/OPS) amphiphilic antifouling biosensor. This amphiphilic electrode, featuring both hydrophilic and hydrophobic properties, demonstrated excellent antifouling performance through electrochemical characterization in ex-vivo blood assays, coupled with commendable sensitivity, stability, and selectivity. CNT-COOH/OPS SPEs were also applied in point-of-care monitoring of the PPF blood concentrations in animals and clinical surgical patients and exhibited good accuracy and linearity (Ipa=0.0084c+0.4458, R<sup>2</sup>=0.995) with a limit of detection of 2.948 μM. Further, the electrodes demonstrated a high recovery and the blood concentrations determined by electrochemical detection had robust negative correlation with the depth of anesthesia. Therefore, CNT-COOH/OPS SPEs hold promise as a significant tool in point-of-care monitoring of PPF, offering patients safer and more personalized medical care.</div></div>\",\"PeriodicalId\":425,\"journal\":{\"name\":\"Sensors and Actuators B: Chemical\",\"volume\":\"424 \",\"pages\":\"Article 136890\"},\"PeriodicalIF\":8.0000,\"publicationDate\":\"2024-11-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors and Actuators B: Chemical\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0925400524016204\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators B: Chemical","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0925400524016204","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

监测异丙酚(PPF)的血液浓度对静脉麻醉的安全性至关重要。电化学传感器是检测丙泊酚的有力工具。我们之前的研究表明,CNT-COOH 电极在抵抗 PPF 氧化产物造成的电化学污垢方面具有优势。然而,生物污垢仍然是阻碍 PPF 电化学传感器临床转化的关键挑战。为了解决这个问题,我们采用原位电沉积的方法,在 CNT-COOH 丝网印刷电极(SPE)上沉积了齐聚物甲基丙烯酸磺基甜菜碱(SBMA)和过氧化多巴胺(OPDA),并提出了一种创新的 CNT-COOH/OPDA-SBMA (CNT-COOH/OPS)两亲性防污生物传感器。这种兼具亲水和疏水特性的两亲电极在体内外血液检测的电化学表征中表现出卓越的防污性能,同时还具有值得称道的灵敏度、稳定性和选择性。CNT-COOH/OPS SPEs 还被应用于动物和临床手术患者血液中 PPF 浓度的床旁监测,表现出良好的准确性和线性(Ipa=0.0084c+0.4458,R2=0.995),检测限为 2.948 μM。此外,电极的恢复能力很强,通过电化学检测确定的血液浓度与麻醉深度呈稳健的负相关。因此,CNT-COOH/OPS SPEs 有望成为床旁监测 PPF 的重要工具,为患者提供更安全、更个性化的医疗服务。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An antibiofouling electrochemical sensor consisting of amphiphilic copolymer on CNT-COOH electrodes for point-of-care monitoring of propofol blood concentration in surgical patients
The monitoring of propofol (PPF) blood concentration is vital for the safety of intravenous anesthesia. Electrochemical sensors represent a powerful tool for the detection of PPF. Our previous research has demonstrated that CNT-COOH electrodes exhibit advantages in resisting electrochemical fouling from PPF oxidation products. Nevertheless, biofouling remains a critical challenge hindering the clinical transformation of PPF electrochemical sensors. To address this issue, we employed in-situ electrodeposition to deposit zwitterionic sulfobetaine methacrylate (SBMA) and overoxidation polydopamine (OPDA) onto CNT-COOH screen-printed electrodes (SPEs) and proposed an innovative CNT-COOH/OPDA-SBMA (CNT-COOH/OPS) amphiphilic antifouling biosensor. This amphiphilic electrode, featuring both hydrophilic and hydrophobic properties, demonstrated excellent antifouling performance through electrochemical characterization in ex-vivo blood assays, coupled with commendable sensitivity, stability, and selectivity. CNT-COOH/OPS SPEs were also applied in point-of-care monitoring of the PPF blood concentrations in animals and clinical surgical patients and exhibited good accuracy and linearity (Ipa=0.0084c+0.4458, R2=0.995) with a limit of detection of 2.948 μM. Further, the electrodes demonstrated a high recovery and the blood concentrations determined by electrochemical detection had robust negative correlation with the depth of anesthesia. Therefore, CNT-COOH/OPS SPEs hold promise as a significant tool in point-of-care monitoring of PPF, offering patients safer and more personalized medical care.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sensors and Actuators B: Chemical
Sensors and Actuators B: Chemical 工程技术-电化学
CiteScore
14.60
自引率
11.90%
发文量
1776
审稿时长
3.2 months
期刊介绍: Sensors & Actuators, B: Chemical is an international journal focused on the research and development of chemical transducers. It covers chemical sensors and biosensors, chemical actuators, and analytical microsystems. The journal is interdisciplinary, aiming to publish original works showcasing substantial advancements beyond the current state of the art in these fields, with practical applicability to solving meaningful analytical problems. Review articles are accepted by invitation from an Editor of the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信