加工方法和边缘设计对整体氧化锆冠的精度和边缘质量的影响

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Yi Zhou, Wenjia Chen, Han Zhu, Xiaochen Liu, Haiping Yang, Fuming He
{"title":"加工方法和边缘设计对整体氧化锆冠的精度和边缘质量的影响","authors":"Yi Zhou, Wenjia Chen, Han Zhu, Xiaochen Liu, Haiping Yang, Fuming He","doi":"10.1016/j.prosdent.2024.10.012","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>The machining accuracy and marginal integrity of monolithic zirconia crowns with minimal invasive preparations may impact the long-term survival rate of tooth and periodontal health, but studies on the effect of machining method are lacking.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to digitally evaluate the machining accuracy and margin quality of monolithic zirconia crowns fabricated using gel deposition and conventional soft milling processes by comparing 2 different margin types.</p><p><strong>Material and methods: </strong>A total of 40 monolithic zirconia crowns were produced using gel deposition (Self-glazed Zirconia Group, SGG, n=20) and soft milling (Milled Zirconia Group, MG, n=20). Each group was further divided into 2 subgroups with different margin designs (chamfer and feather-edge). The trueness and fit of crowns were compared using root mean square (RMS) values. Furthermore, the margin quality was examined before and after final sintering with a scanning electron microscope (SEM). The Scheirer-Ray-Hare and 2-way ANOVA test analysis nonparametric and parametric data, respectively (α=.05).</p><p><strong>Results: </strong>The trueness analysis revealed that SGG had significantly lower RMS values for both the cameo and intaglio areas compared with MG (P<.001). In addition, crowns with a feather-edge margin exhibited significantly lower marginal RMS values than those with a chamfer margin (P<.01) according to the fit assessment. Followed by milling processes, SGG exhibited a constantly homogeneous microstructure compared with MG. Marginal defects were detected in both groups except for the SGG with the chamfer margin.</p><p><strong>Conclusions: </strong>SGG exhibited better accuracy associated with ductile-regime machining than MG, and SGG with chamfer margins displayed flaw-free margin areas. Moreover, the feather-edge margin showed improved marginal fit compared with the chamfer margin.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of machining method and margin design on the accuracy and margin quality of monolithic zirconia crowns.\",\"authors\":\"Yi Zhou, Wenjia Chen, Han Zhu, Xiaochen Liu, Haiping Yang, Fuming He\",\"doi\":\"10.1016/j.prosdent.2024.10.012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Statement of problem: </strong>The machining accuracy and marginal integrity of monolithic zirconia crowns with minimal invasive preparations may impact the long-term survival rate of tooth and periodontal health, but studies on the effect of machining method are lacking.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to digitally evaluate the machining accuracy and margin quality of monolithic zirconia crowns fabricated using gel deposition and conventional soft milling processes by comparing 2 different margin types.</p><p><strong>Material and methods: </strong>A total of 40 monolithic zirconia crowns were produced using gel deposition (Self-glazed Zirconia Group, SGG, n=20) and soft milling (Milled Zirconia Group, MG, n=20). Each group was further divided into 2 subgroups with different margin designs (chamfer and feather-edge). The trueness and fit of crowns were compared using root mean square (RMS) values. Furthermore, the margin quality was examined before and after final sintering with a scanning electron microscope (SEM). The Scheirer-Ray-Hare and 2-way ANOVA test analysis nonparametric and parametric data, respectively (α=.05).</p><p><strong>Results: </strong>The trueness analysis revealed that SGG had significantly lower RMS values for both the cameo and intaglio areas compared with MG (P<.001). In addition, crowns with a feather-edge margin exhibited significantly lower marginal RMS values than those with a chamfer margin (P<.01) according to the fit assessment. Followed by milling processes, SGG exhibited a constantly homogeneous microstructure compared with MG. Marginal defects were detected in both groups except for the SGG with the chamfer margin.</p><p><strong>Conclusions: </strong>SGG exhibited better accuracy associated with ductile-regime machining than MG, and SGG with chamfer margins displayed flaw-free margin areas. Moreover, the feather-edge margin showed improved marginal fit compared with the chamfer margin.</p>\",\"PeriodicalId\":16866,\"journal\":{\"name\":\"Journal of Prosthetic Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-11-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthetic Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.prosdent.2024.10.012\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2024.10.012","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

问题陈述:微创制备的整体氧化锆冠的加工精度和边缘完整性可能会影响牙齿的长期存活率和牙周健康,但缺乏有关加工方法影响的研究。目的:本体外研究的目的是通过比较2种不同的边缘类型,对使用凝胶沉积和传统软铣工艺制作的整体氧化锆冠的加工精度和边缘质量进行数字化评估:使用凝胶沉积法(自釉氧化锆组,SGG,n=20)和软铣法(铣削氧化锆组,MG,n=20)共制作了 40 个整体氧化锆冠。每组又分为两个边缘设计(倒角和羽状边缘)不同的亚组。使用均方根(RMS)值比较牙冠的真实度和密合度。此外,还使用扫描电子显微镜(SEM)检查了最终烧结前后的边缘质量。分别采用 Scheirer-Ray-Hare 和 2-way ANOVA 检验分析非参数数据和参数数据(α=.05):真实度分析表明,与 MG 相比,SGG 在浮雕和凹雕区域的均方根值明显较低(PConclusions):与 MG 相比,SGG 表现出更好的韧性机械加工精度,带有倒角边缘的 SGG 显示出无缺陷的边缘区域。此外,与倒角边缘相比,羽边边缘的边缘贴合度有所提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of machining method and margin design on the accuracy and margin quality of monolithic zirconia crowns.

Statement of problem: The machining accuracy and marginal integrity of monolithic zirconia crowns with minimal invasive preparations may impact the long-term survival rate of tooth and periodontal health, but studies on the effect of machining method are lacking.

Purpose: The purpose of this in vitro study was to digitally evaluate the machining accuracy and margin quality of monolithic zirconia crowns fabricated using gel deposition and conventional soft milling processes by comparing 2 different margin types.

Material and methods: A total of 40 monolithic zirconia crowns were produced using gel deposition (Self-glazed Zirconia Group, SGG, n=20) and soft milling (Milled Zirconia Group, MG, n=20). Each group was further divided into 2 subgroups with different margin designs (chamfer and feather-edge). The trueness and fit of crowns were compared using root mean square (RMS) values. Furthermore, the margin quality was examined before and after final sintering with a scanning electron microscope (SEM). The Scheirer-Ray-Hare and 2-way ANOVA test analysis nonparametric and parametric data, respectively (α=.05).

Results: The trueness analysis revealed that SGG had significantly lower RMS values for both the cameo and intaglio areas compared with MG (P<.001). In addition, crowns with a feather-edge margin exhibited significantly lower marginal RMS values than those with a chamfer margin (P<.01) according to the fit assessment. Followed by milling processes, SGG exhibited a constantly homogeneous microstructure compared with MG. Marginal defects were detected in both groups except for the SGG with the chamfer margin.

Conclusions: SGG exhibited better accuracy associated with ductile-regime machining than MG, and SGG with chamfer margins displayed flaw-free margin areas. Moreover, the feather-edge margin showed improved marginal fit compared with the chamfer margin.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信