开发 GeV 光子实时光束轮廓监测器及其在加速器设施中的应用

IF 1.5 3区 物理与天体物理 Q3 INSTRUMENTS & INSTRUMENTATION
R. Kino , S. Nagao , T. Akiyama , H. Fujioka , T. Fujiwara , T. Ishige , K. Itabashi , S. Kajikawa , M. Kaneta , M. Mizuno , S.N. Nakamura , K. Nishi , K. Nishida , K. Okuyama , F. Oura , K. Tachibana , Y. Toyama , D. Watanabe
{"title":"开发 GeV 光子实时光束轮廓监测器及其在加速器设施中的应用","authors":"R. Kino ,&nbsp;S. Nagao ,&nbsp;T. Akiyama ,&nbsp;H. Fujioka ,&nbsp;T. Fujiwara ,&nbsp;T. Ishige ,&nbsp;K. Itabashi ,&nbsp;S. Kajikawa ,&nbsp;M. Kaneta ,&nbsp;M. Mizuno ,&nbsp;S.N. Nakamura ,&nbsp;K. Nishi ,&nbsp;K. Nishida ,&nbsp;K. Okuyama ,&nbsp;F. Oura ,&nbsp;K. Tachibana ,&nbsp;Y. Toyama ,&nbsp;D. Watanabe","doi":"10.1016/j.nima.2024.169992","DOIUrl":null,"url":null,"abstract":"<div><div>A real-time beam profile monitoring system is proposed for GeV photon beams at the BM4 beamline of the Mikamine site, Research Center for Accelerator and Radioisotope Science (RARiS; previously known as ELPH) at Tohoku University. This monitoring system enhances the capability to monitor the entire beamline by incorporating newly developed beam profile monitors (BPMs) for upstream and midstream sections, in addition to the existing high-speed BPM used for downstream monitoring. This paper reports on the detection mechanisms of the newly developed BPMs and the actual measurement results obtained using the integrated beam monitoring system. The new BPMs are composed of plastic scintillation fibers and silicon photomultipliers, enabling high-precision, real-time measurements. Data acquisition utilizes streaming TDC, a firmware commonly employed in the J-PARC Hadron-hall, allowing real-time detection of high-intensity photon beams with count rates reaching several tens of MHz. With sufficient statistical data, the BPM achieved a 1-s beam-profiling accuracy of 10 <span><math><mrow><mi>μ</mi><mi>m</mi></mrow></math></span>. The proposed BPM system serves as a valuable resource for future physics experiments at the BM4 photon beamline and will significantly contribute to ongoing accelerator research endeavors.</div></div>","PeriodicalId":19359,"journal":{"name":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","volume":"1070 ","pages":"Article 169992"},"PeriodicalIF":1.5000,"publicationDate":"2024-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of a real-time beam profile monitor for GeV photons and its application in accelerator facilities\",\"authors\":\"R. Kino ,&nbsp;S. Nagao ,&nbsp;T. Akiyama ,&nbsp;H. Fujioka ,&nbsp;T. Fujiwara ,&nbsp;T. Ishige ,&nbsp;K. Itabashi ,&nbsp;S. Kajikawa ,&nbsp;M. Kaneta ,&nbsp;M. Mizuno ,&nbsp;S.N. Nakamura ,&nbsp;K. Nishi ,&nbsp;K. Nishida ,&nbsp;K. Okuyama ,&nbsp;F. Oura ,&nbsp;K. Tachibana ,&nbsp;Y. Toyama ,&nbsp;D. Watanabe\",\"doi\":\"10.1016/j.nima.2024.169992\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>A real-time beam profile monitoring system is proposed for GeV photon beams at the BM4 beamline of the Mikamine site, Research Center for Accelerator and Radioisotope Science (RARiS; previously known as ELPH) at Tohoku University. This monitoring system enhances the capability to monitor the entire beamline by incorporating newly developed beam profile monitors (BPMs) for upstream and midstream sections, in addition to the existing high-speed BPM used for downstream monitoring. This paper reports on the detection mechanisms of the newly developed BPMs and the actual measurement results obtained using the integrated beam monitoring system. The new BPMs are composed of plastic scintillation fibers and silicon photomultipliers, enabling high-precision, real-time measurements. Data acquisition utilizes streaming TDC, a firmware commonly employed in the J-PARC Hadron-hall, allowing real-time detection of high-intensity photon beams with count rates reaching several tens of MHz. With sufficient statistical data, the BPM achieved a 1-s beam-profiling accuracy of 10 <span><math><mrow><mi>μ</mi><mi>m</mi></mrow></math></span>. The proposed BPM system serves as a valuable resource for future physics experiments at the BM4 photon beamline and will significantly contribute to ongoing accelerator research endeavors.</div></div>\",\"PeriodicalId\":19359,\"journal\":{\"name\":\"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment\",\"volume\":\"1070 \",\"pages\":\"Article 169992\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-10-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0168900224009185\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0168900224009185","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

针对东北大学加速器和放射性同位素科学研究中心(RARiS,以前称为 ELPH)三峰基地 BM4 光束线的 GeV 光子束,提出了一种实时光束剖面监测系统。除了用于下游监测的现有高速光束轮廓监测器(BPM)之外,该监测系统还为上游和中游部分安装了新开发的光束轮廓监测器(BPM),从而增强了对整个光束线的监测能力。本文报告了新开发的 BPM 的检测机制以及使用集成光束监测系统获得的实际测量结果。新的 BPM 由塑料闪烁光纤和硅光电倍增管组成,能够进行高精度的实时测量。数据采集采用流式 TDC,这是 J-PARC Hadron-hall 常用的固件,可以实时检测计数率高达几十兆赫的高强度光子束。有了足够的统计数据,BPM 实现了 10 μm 的 1 秒光束轮廓精度。拟议的 BPM 系统将成为 BM4 光子光束线未来物理实验的宝贵资源,并将为正在进行的加速器研究工作做出重大贡献。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a real-time beam profile monitor for GeV photons and its application in accelerator facilities
A real-time beam profile monitoring system is proposed for GeV photon beams at the BM4 beamline of the Mikamine site, Research Center for Accelerator and Radioisotope Science (RARiS; previously known as ELPH) at Tohoku University. This monitoring system enhances the capability to monitor the entire beamline by incorporating newly developed beam profile monitors (BPMs) for upstream and midstream sections, in addition to the existing high-speed BPM used for downstream monitoring. This paper reports on the detection mechanisms of the newly developed BPMs and the actual measurement results obtained using the integrated beam monitoring system. The new BPMs are composed of plastic scintillation fibers and silicon photomultipliers, enabling high-precision, real-time measurements. Data acquisition utilizes streaming TDC, a firmware commonly employed in the J-PARC Hadron-hall, allowing real-time detection of high-intensity photon beams with count rates reaching several tens of MHz. With sufficient statistical data, the BPM achieved a 1-s beam-profiling accuracy of 10 μm. The proposed BPM system serves as a valuable resource for future physics experiments at the BM4 photon beamline and will significantly contribute to ongoing accelerator research endeavors.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.20
自引率
21.40%
发文量
787
审稿时长
1 months
期刊介绍: Section A of Nuclear Instruments and Methods in Physics Research publishes papers on design, manufacturing and performance of scientific instruments with an emphasis on large scale facilities. This includes the development of particle accelerators, ion sources, beam transport systems and target arrangements as well as the use of secondary phenomena such as synchrotron radiation and free electron lasers. It also includes all types of instrumentation for the detection and spectrometry of radiations from high energy processes and nuclear decays, as well as instrumentation for experiments at nuclear reactors. Specialized electronics for nuclear and other types of spectrometry as well as computerization of measurements and control systems in this area also find their place in the A section. Theoretical as well as experimental papers are accepted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信