经皮冠状动脉介入治疗过程中的生物可吸收支架卸载:早期检测和管理。

IF 1.9 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Nabil Eid, Mohamed Abdel Wahab, Amardev Singh Thanu
{"title":"经皮冠状动脉介入治疗过程中的生物可吸收支架卸载:早期检测和管理。","authors":"Nabil Eid, Mohamed Abdel Wahab, Amardev Singh Thanu","doi":"10.4330/wjc.v16.i10.616","DOIUrl":null,"url":null,"abstract":"<p><p>In this letter, we comment on a recent case report by Sun <i>et al</i> in the <i>World Journal of Cardiology</i>. The report describes the successful management of a rare complication: The unloading or detachment of a bioresorbable stent (BRS) during percutaneous coronary intervention (PCI) in a male patient. The unloading of BRS was detected <i>via</i> angiography and intravascular ultrasound (IVUS) imaging of the left coronary artery and left anterior descending artery. Although this case is interesting, the authors' report lacked crucial details. Specifically, insufficient information about the type of BRS used, potential causes of BRS unloading, or whether optical coherence tomography (OCT) imaging for coronary arteries was performed before, during, or after PCI. The OCT imaging of coronary arteries before PCI can potentially prevent BRS unloading due to its higher resolution compared to IVUS. In addition, despite detecting myocardial bridging during the PCI, the authors did not provide any details regarding this variation. Here we discuss the various types of BRS, the importance of OCT in PCI, and the clinical relevance of myocardial bridging.</p>","PeriodicalId":23800,"journal":{"name":"World Journal of Cardiology","volume":"16 10","pages":"616-618"},"PeriodicalIF":1.9000,"publicationDate":"2024-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11525804/pdf/","citationCount":"0","resultStr":"{\"title\":\"Bioresorbable stent unloading during percutaneous coronary intervention: Early detection and management.\",\"authors\":\"Nabil Eid, Mohamed Abdel Wahab, Amardev Singh Thanu\",\"doi\":\"10.4330/wjc.v16.i10.616\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In this letter, we comment on a recent case report by Sun <i>et al</i> in the <i>World Journal of Cardiology</i>. The report describes the successful management of a rare complication: The unloading or detachment of a bioresorbable stent (BRS) during percutaneous coronary intervention (PCI) in a male patient. The unloading of BRS was detected <i>via</i> angiography and intravascular ultrasound (IVUS) imaging of the left coronary artery and left anterior descending artery. Although this case is interesting, the authors' report lacked crucial details. Specifically, insufficient information about the type of BRS used, potential causes of BRS unloading, or whether optical coherence tomography (OCT) imaging for coronary arteries was performed before, during, or after PCI. The OCT imaging of coronary arteries before PCI can potentially prevent BRS unloading due to its higher resolution compared to IVUS. In addition, despite detecting myocardial bridging during the PCI, the authors did not provide any details regarding this variation. Here we discuss the various types of BRS, the importance of OCT in PCI, and the clinical relevance of myocardial bridging.</p>\",\"PeriodicalId\":23800,\"journal\":{\"name\":\"World Journal of Cardiology\",\"volume\":\"16 10\",\"pages\":\"616-618\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-10-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11525804/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"World Journal of Cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4330/wjc.v16.i10.616\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4330/wjc.v16.i10.616","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

在这封信中,我们对 Sun 等人最近在《世界心脏病学杂志》上发表的一篇病例报告进行了评论。该报告描述了对一种罕见并发症的成功处理:一名男性患者在经皮冠状动脉介入治疗(PCI)过程中发生生物可吸收支架(BRS)卸载或脱落。BRS的卸载是通过左冠状动脉和左前降支动脉的血管造影和血管内超声(IVUS)成像发现的。尽管该病例很有趣,但作者的报告缺乏关键细节。具体来说,关于所使用的 BRS 类型、BRS 卸载的潜在原因、PCI 之前、期间或之后是否对冠状动脉进行了光学相干断层扫描(OCT)成像等信息不足。与 IVUS 相比,PCI 前冠状动脉的 OCT 成像分辨率更高,因此有可能防止 BRS 卸载。此外,尽管在 PCI 过程中检测到了心肌桥接,但作者并未提供有关这种变化的任何细节。在此,我们将讨论各种类型的 BRS、OCT 在 PCI 中的重要性以及心肌桥接的临床意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Bioresorbable stent unloading during percutaneous coronary intervention: Early detection and management.

In this letter, we comment on a recent case report by Sun et al in the World Journal of Cardiology. The report describes the successful management of a rare complication: The unloading or detachment of a bioresorbable stent (BRS) during percutaneous coronary intervention (PCI) in a male patient. The unloading of BRS was detected via angiography and intravascular ultrasound (IVUS) imaging of the left coronary artery and left anterior descending artery. Although this case is interesting, the authors' report lacked crucial details. Specifically, insufficient information about the type of BRS used, potential causes of BRS unloading, or whether optical coherence tomography (OCT) imaging for coronary arteries was performed before, during, or after PCI. The OCT imaging of coronary arteries before PCI can potentially prevent BRS unloading due to its higher resolution compared to IVUS. In addition, despite detecting myocardial bridging during the PCI, the authors did not provide any details regarding this variation. Here we discuss the various types of BRS, the importance of OCT in PCI, and the clinical relevance of myocardial bridging.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
World Journal of Cardiology
World Journal of Cardiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.30
自引率
5.30%
发文量
54
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信