采用新设计理念的牙髓显微手术三维手术导板的精确性:尸体研究

IF 5.4 1区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Se-Won Ha, Stephanie M Choi, Sunil Kim, Minju Song, Kyung-Seok Hu, Euiseong Kim
{"title":"采用新设计理念的牙髓显微手术三维手术导板的精确性:尸体研究","authors":"Se-Won Ha, Stephanie M Choi, Sunil Kim, Minju Song, Kyung-Seok Hu, Euiseong Kim","doi":"10.1111/iej.14161","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>Despite the high success rate of endodontic microsurgery (EMS), it is difficult to suggest EMS as a general treatment option considering the difficulty of the procedure. A surgical guide has been proposed to overcome this problem. This study aimed to evaluate the stability of the surgical guide of a new design concept, as well as the accuracy of root resection, and to introduce the manufacturing method of the newly designed surgical guide.</p><p><strong>Methodology: </strong>The experiment was conducted on 59 roots (9 in the maxillary and 50 in the mandibular region) of adult human cadavers. The surgical guide was designed using CAD/CAM design software based on cone-beam computed tomography (CBCT) images and optical scan files. Unlike conventional surgical guides, the surgical guide proposed herein was designed to act as a tooth-bone-supported removable appliance. Two different types of guides were prepared: the osteotomy guide (O guide) for separation of the cortical bone above the root tip with a trephine bur with an outer diameter of 6 mm and the root resection guide (R guide) for resection of the root tip with a trephine bur with an outer diameter of 4 mm. For stability evaluation, the guides were pressed at five predetermined locations after installation and checked for the presence of any movement. For accuracy evaluation, the length at which the root tip was cut was measured and examined by overlapping the preoperative and postoperative CBCT images.</p><p><strong>Results: </strong>Of the 15 R guides, 14 were stably installed without mobility. For the R guide group, the root tip was resected with an average of 3.2 mm, showing better results than the no-guide group with an average of 4.0 mm.</p><p><strong>Conclusions: </strong>The newly designed surgical guide of this study can be applied more stably, enabling root resection to be performed more accurately and simply according to the preoperative plan than when performed without a guide.</p>","PeriodicalId":13724,"journal":{"name":"International endodontic journal","volume":null,"pages":null},"PeriodicalIF":5.4000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy of 3-dimensional surgical guide for endodontic microsurgery with a new design concept: A cadaver study.\",\"authors\":\"Se-Won Ha, Stephanie M Choi, Sunil Kim, Minju Song, Kyung-Seok Hu, Euiseong Kim\",\"doi\":\"10.1111/iej.14161\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>Despite the high success rate of endodontic microsurgery (EMS), it is difficult to suggest EMS as a general treatment option considering the difficulty of the procedure. A surgical guide has been proposed to overcome this problem. This study aimed to evaluate the stability of the surgical guide of a new design concept, as well as the accuracy of root resection, and to introduce the manufacturing method of the newly designed surgical guide.</p><p><strong>Methodology: </strong>The experiment was conducted on 59 roots (9 in the maxillary and 50 in the mandibular region) of adult human cadavers. The surgical guide was designed using CAD/CAM design software based on cone-beam computed tomography (CBCT) images and optical scan files. Unlike conventional surgical guides, the surgical guide proposed herein was designed to act as a tooth-bone-supported removable appliance. Two different types of guides were prepared: the osteotomy guide (O guide) for separation of the cortical bone above the root tip with a trephine bur with an outer diameter of 6 mm and the root resection guide (R guide) for resection of the root tip with a trephine bur with an outer diameter of 4 mm. For stability evaluation, the guides were pressed at five predetermined locations after installation and checked for the presence of any movement. For accuracy evaluation, the length at which the root tip was cut was measured and examined by overlapping the preoperative and postoperative CBCT images.</p><p><strong>Results: </strong>Of the 15 R guides, 14 were stably installed without mobility. For the R guide group, the root tip was resected with an average of 3.2 mm, showing better results than the no-guide group with an average of 4.0 mm.</p><p><strong>Conclusions: </strong>The newly designed surgical guide of this study can be applied more stably, enabling root resection to be performed more accurately and simply according to the preoperative plan than when performed without a guide.</p>\",\"PeriodicalId\":13724,\"journal\":{\"name\":\"International endodontic journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.4000,\"publicationDate\":\"2024-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International endodontic journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/iej.14161\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International endodontic journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/iej.14161","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:尽管牙髓显微外科手术(EMS)的成功率很高,但考虑到手术的难度,很难建议将 EMS 作为一般治疗方案。为了解决这一问题,人们提出了一种手术导板。本研究旨在评估新设计理念手术导板的稳定性以及根切除的准确性,并介绍新设计手术导板的制造方法:实验对象为成人尸体的 59 根牙根(上颌 9 根,下颌 50 根)。根据锥束计算机断层扫描(CBCT)图像和光学扫描文件,使用 CAD/CAM 设计软件设计了手术导板。与传统的手术导板不同,本文提出的手术导板被设计成牙骨质支撑的可移动矫治器。制备了两种不同类型的导板:截骨导板(O 型导板),用于用外径为 6 毫米的穿刺针分离根尖上方的皮质骨;根切除导板(R 型导板),用于用外径为 4 毫米的穿刺针切除根尖。在稳定性评估方面,安装后在五个预定位置按压导板,检查导板是否有移动。在准确性评估方面,通过重叠术前和术后的 CBCT 图像来测量和检查根尖切割的长度:结果:在 15 个 R 导板中,14 个导板安装稳定,没有移动。R 导板组切除的根尖平均为 3.2 毫米,比无导板组的平均 4.0 毫米效果更好:本研究中新设计的手术导板能更稳定地应用,与无导板相比,能更准确、更简单地根据术前计划进行牙根切除。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy of 3-dimensional surgical guide for endodontic microsurgery with a new design concept: A cadaver study.

Aim: Despite the high success rate of endodontic microsurgery (EMS), it is difficult to suggest EMS as a general treatment option considering the difficulty of the procedure. A surgical guide has been proposed to overcome this problem. This study aimed to evaluate the stability of the surgical guide of a new design concept, as well as the accuracy of root resection, and to introduce the manufacturing method of the newly designed surgical guide.

Methodology: The experiment was conducted on 59 roots (9 in the maxillary and 50 in the mandibular region) of adult human cadavers. The surgical guide was designed using CAD/CAM design software based on cone-beam computed tomography (CBCT) images and optical scan files. Unlike conventional surgical guides, the surgical guide proposed herein was designed to act as a tooth-bone-supported removable appliance. Two different types of guides were prepared: the osteotomy guide (O guide) for separation of the cortical bone above the root tip with a trephine bur with an outer diameter of 6 mm and the root resection guide (R guide) for resection of the root tip with a trephine bur with an outer diameter of 4 mm. For stability evaluation, the guides were pressed at five predetermined locations after installation and checked for the presence of any movement. For accuracy evaluation, the length at which the root tip was cut was measured and examined by overlapping the preoperative and postoperative CBCT images.

Results: Of the 15 R guides, 14 were stably installed without mobility. For the R guide group, the root tip was resected with an average of 3.2 mm, showing better results than the no-guide group with an average of 4.0 mm.

Conclusions: The newly designed surgical guide of this study can be applied more stably, enabling root resection to be performed more accurately and simply according to the preoperative plan than when performed without a guide.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International endodontic journal
International endodontic journal 医学-牙科与口腔外科
CiteScore
10.20
自引率
28.00%
发文量
195
审稿时长
4-8 weeks
期刊介绍: The International Endodontic Journal is published monthly and strives to publish original articles of the highest quality to disseminate scientific and clinical knowledge; all manuscripts are subjected to peer review. Original scientific articles are published in the areas of biomedical science, applied materials science, bioengineering, epidemiology and social science relevant to endodontic disease and its management, and to the restoration of root-treated teeth. In addition, review articles, reports of clinical cases, book reviews, summaries and abstracts of scientific meetings and news items are accepted. The International Endodontic Journal is essential reading for general dental practitioners, specialist endodontists, research, scientists and dental teachers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信