设计并构建一个用于收集和报告放射诊断参考水平(DRL)的网站。

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Narongsak Chaychid , Kaiwit Bunta , Panatsada Awikunprasert , Kamonwan Sangsuwan , Chaleomchok Wuttanatum , Natharin Duksukkeaw
{"title":"设计并构建一个用于收集和报告放射诊断参考水平(DRL)的网站。","authors":"Narongsak Chaychid ,&nbsp;Kaiwit Bunta ,&nbsp;Panatsada Awikunprasert ,&nbsp;Kamonwan Sangsuwan ,&nbsp;Chaleomchok Wuttanatum ,&nbsp;Natharin Duksukkeaw","doi":"10.1016/j.jmir.2024.101783","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>The preparation of reports and calculation of dose reference levels (DRLs) for general x-ray radiography are valuable tools for determining appropriate radiation dosage. However, the systematic collection of dose-area product (DAP) dose data can be challenging, and calculating entrance surface air kerma (ESAK)values requires precision and careful calculations<strong>.</strong></div></div><div><h3>Objective</h3><div>The aim of this study was to design and implement a website for the collection of DAP values, calculation of ESAK values, and reporting of DRLs from general diagnostic radiographs. Additionally, the study evaluated the quality and satisfaction of radiological technologists using the website.</div></div><div><h3>Methods</h3><div>Website design considerations included navigation, database management, and the development of an interactive web application for displaying and validating calculations. Subsequently, the website was made available to 16 volunteers for evaluation of its effectiveness and user satisfaction.</div></div><div><h3>Results</h3><div>The developed website functioned properly and was capable of recording DAP data, calculating ESAK values, and generating reports on DRL values. Verification of the ESAK and DRL calculations by four experts confirmed their accuracy. The content evaluation yielded a mean score of 4.71 ± 0.49 for content, 4.59 ± 0.65 for usability, 4.55 ± 0.59 for website format, and 4.61 ± 0.60 for overall satisfaction.</div></div><div><h3>Conclusion</h3><div>A website designed for the collection and reporting of DRLs in general diagnostic radiography offered practical application potential. Its functionalities could enhance the work efficiency of radiological technologists and contribute to improved radiation optimization and protection.</div></div>","PeriodicalId":46420,"journal":{"name":"Journal of Medical Imaging and Radiation Sciences","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The design and construct a website for collection and report diagnostic reference levels (DRLs) in diagnostic radiography\",\"authors\":\"Narongsak Chaychid ,&nbsp;Kaiwit Bunta ,&nbsp;Panatsada Awikunprasert ,&nbsp;Kamonwan Sangsuwan ,&nbsp;Chaleomchok Wuttanatum ,&nbsp;Natharin Duksukkeaw\",\"doi\":\"10.1016/j.jmir.2024.101783\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>The preparation of reports and calculation of dose reference levels (DRLs) for general x-ray radiography are valuable tools for determining appropriate radiation dosage. However, the systematic collection of dose-area product (DAP) dose data can be challenging, and calculating entrance surface air kerma (ESAK)values requires precision and careful calculations<strong>.</strong></div></div><div><h3>Objective</h3><div>The aim of this study was to design and implement a website for the collection of DAP values, calculation of ESAK values, and reporting of DRLs from general diagnostic radiographs. Additionally, the study evaluated the quality and satisfaction of radiological technologists using the website.</div></div><div><h3>Methods</h3><div>Website design considerations included navigation, database management, and the development of an interactive web application for displaying and validating calculations. Subsequently, the website was made available to 16 volunteers for evaluation of its effectiveness and user satisfaction.</div></div><div><h3>Results</h3><div>The developed website functioned properly and was capable of recording DAP data, calculating ESAK values, and generating reports on DRL values. Verification of the ESAK and DRL calculations by four experts confirmed their accuracy. The content evaluation yielded a mean score of 4.71 ± 0.49 for content, 4.59 ± 0.65 for usability, 4.55 ± 0.59 for website format, and 4.61 ± 0.60 for overall satisfaction.</div></div><div><h3>Conclusion</h3><div>A website designed for the collection and reporting of DRLs in general diagnostic radiography offered practical application potential. Its functionalities could enhance the work efficiency of radiological technologists and contribute to improved radiation optimization and protection.</div></div>\",\"PeriodicalId\":46420,\"journal\":{\"name\":\"Journal of Medical Imaging and Radiation Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-11-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Imaging and Radiation Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1939865424005149\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Imaging and Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1939865424005149","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:为普通 X 射线放射摄影编制报告和计算剂量参考水平(DRLs)是确定适当辐射剂量的重要工具。然而,系统地收集剂量-面积乘积(DAP)剂量数据具有挑战性,计算入口表面空气开玛(ESAK)值需要精确和仔细的计算:本研究旨在设计并实施一个网站,用于收集 DAP 值、计算 ESAK 值以及报告普通放射诊断照片的 DRL。此外,该研究还对放射技术人员使用该网站的质量和满意度进行了评估:网站设计考虑的因素包括导航、数据库管理以及用于显示和验证计算结果的交互式网络应用程序的开发。随后,16 名志愿者对网站的有效性和用户满意度进行了评估:结果:开发的网站功能正常,能够记录 DAP 数据、计算 ESAK 值并生成 DRL 值报告。四位专家对 ESAK 和 DRL 的计算结果进行了验证,确认了其准确性。内容评估的平均得分为 4.71 ± 0.49 分,可用性为 4.59 ± 0.65 分,网站格式为 4.55 ± 0.59 分,总体满意度为 4.61 ± 0.60 分:为普通放射诊断收集和报告 DRL 而设计的网站具有实际应用潜力。其功能可提高放射技术人员的工作效率,有助于改善辐射优化和防护。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The design and construct a website for collection and report diagnostic reference levels (DRLs) in diagnostic radiography

Background

The preparation of reports and calculation of dose reference levels (DRLs) for general x-ray radiography are valuable tools for determining appropriate radiation dosage. However, the systematic collection of dose-area product (DAP) dose data can be challenging, and calculating entrance surface air kerma (ESAK)values requires precision and careful calculations.

Objective

The aim of this study was to design and implement a website for the collection of DAP values, calculation of ESAK values, and reporting of DRLs from general diagnostic radiographs. Additionally, the study evaluated the quality and satisfaction of radiological technologists using the website.

Methods

Website design considerations included navigation, database management, and the development of an interactive web application for displaying and validating calculations. Subsequently, the website was made available to 16 volunteers for evaluation of its effectiveness and user satisfaction.

Results

The developed website functioned properly and was capable of recording DAP data, calculating ESAK values, and generating reports on DRL values. Verification of the ESAK and DRL calculations by four experts confirmed their accuracy. The content evaluation yielded a mean score of 4.71 ± 0.49 for content, 4.59 ± 0.65 for usability, 4.55 ± 0.59 for website format, and 4.61 ± 0.60 for overall satisfaction.

Conclusion

A website designed for the collection and reporting of DRLs in general diagnostic radiography offered practical application potential. Its functionalities could enhance the work efficiency of radiological technologists and contribute to improved radiation optimization and protection.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Medical Imaging and Radiation Sciences
Journal of Medical Imaging and Radiation Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.30
自引率
11.10%
发文量
231
审稿时长
53 days
期刊介绍: Journal of Medical Imaging and Radiation Sciences is the official peer-reviewed journal of the Canadian Association of Medical Radiation Technologists. This journal is published four times a year and is circulated to approximately 11,000 medical radiation technologists, libraries and radiology departments throughout Canada, the United States and overseas. The Journal publishes articles on recent research, new technology and techniques, professional practices, technologists viewpoints as well as relevant book reviews.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信