对接受小梁显微手术的开角型青光眼或眼压过高患者的疗效、安全性和病情进展进行为期三年的分析。

Q3 Medicine
M. Parrilla Vallejo , J.A. Aguiar Caro , M. Girón Ortega , C.J. Cortés Laborda , M.J. Cano Gómez , P. Molina Solana , E. Rodríguez de la Rúa Franch
{"title":"对接受小梁显微手术的开角型青光眼或眼压过高患者的疗效、安全性和病情进展进行为期三年的分析。","authors":"M. Parrilla Vallejo ,&nbsp;J.A. Aguiar Caro ,&nbsp;M. Girón Ortega ,&nbsp;C.J. Cortés Laborda ,&nbsp;M.J. Cano Gómez ,&nbsp;P. Molina Solana ,&nbsp;E. Rodríguez de la Rúa Franch","doi":"10.1016/j.oftal.2024.06.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Aim</h3><div>To evaluate the efficacy, safety, structural and functional progression following the insertion of iStent inject ® implants in patients with open-angle glaucoma or ocular hypertension at a tertiary-level hospital.</div></div><div><h3>Materials and methods</h3><div>A retrospective study included 98 eyes (57 males and 41 females) with open-angle glaucoma or ocular hypertension, which underwent iStent inject W® implantation (Glaukos, Corporation, CA) between December 2018 and December 2022. Differences in intraocular pressure (IOP), the number of hypotensive eye drops used, and structural and functional tests were assessed between preoperative values and subsequent reviews during a follow-up period of one (n<!--> <!-->=<!--> <!-->98), two (n<!--> <!-->=<!--> <!-->55), and three years (n<!--> <!-->=<!--> <!-->15) after surgery.</div></div><div><h3>Results</h3><div>Among the 98 eyes studied, 85% were diagnosed with open-angle glaucoma (50% mild, 32% moderate, and 18% severe) and 15% with ocular hypertension. There was a statistically significant reduction in IOP compared to preoperative values for all visits except the 1-month (p<!--> <!-->=<!--> <!-->0.36) and 3-year (p<!--> <!-->=<!--> <!-->0.39) visits. Visual acuity increased from 0.39<!--> <!-->±<!--> <!-->0.25 to 0.72<!--> <!-->±<!--> <!-->0.24 (p&lt;<!--> <!-->0.01), considering that a significant portion of the interventions included cataract surgery. Before surgery, 66% of the sample used 2 or more hypotensive medications. Post-surgery, the number of hypotensive medications decreased (from 1.88<!--> <!-->±<!--> <!-->0.84 to 0.21<!--> <!-->±<!--> <!-->0.59 at 3 years) (p&lt;<!--> <!-->0.01), with an 88.9% reduction in the number of medications over three years. After surgery, 75% of cases did not require any medication.</div><div>Regarding structural and functional tests, thickness of retinal nerve fiber layers (RNFL (p<!--> <!-->=<!--> <!-->0.35), excavation / papilla ratio E/P (p<!--> <!-->=<!--> <!-->0.31), visual function index</div><div>(VFI (p<!--> <!-->=<!--> <!-->0.06), and deviation mean (MD (p<!--> <!-->=<!--> <!-->0.06) showed no statistically significant differences post-intervention. However, standard deviation of the pattern (DSM) did exhibit differences, decreasing from 5.46<!--> <!-->±<!--> <!-->4.03<!--> <!-->dB to 5.34<!--> <!-->±<!--> <!-->3.48<!--> <!-->dB (p<!--> <!-->=<!--> <!-->0.02).</div></div><div><h3>Conclusion</h3><div>The results of this study suggest that the iStent inject W® technique constitutes an effective and safe option for tension control and glaucoma treatment.</div></div>","PeriodicalId":8348,"journal":{"name":"Archivos De La Sociedad Espanola De Oftalmologia","volume":"99 11","pages":"Pages 485-492"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Análisis a tres años de resultados, seguridad y progresión en pacientes con glaucoma de ángulo abierto o hipertensión ocular, intervenidos de microcirugía trabecular\",\"authors\":\"M. Parrilla Vallejo ,&nbsp;J.A. Aguiar Caro ,&nbsp;M. Girón Ortega ,&nbsp;C.J. Cortés Laborda ,&nbsp;M.J. Cano Gómez ,&nbsp;P. Molina Solana ,&nbsp;E. Rodríguez de la Rúa Franch\",\"doi\":\"10.1016/j.oftal.2024.06.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Aim</h3><div>To evaluate the efficacy, safety, structural and functional progression following the insertion of iStent inject ® implants in patients with open-angle glaucoma or ocular hypertension at a tertiary-level hospital.</div></div><div><h3>Materials and methods</h3><div>A retrospective study included 98 eyes (57 males and 41 females) with open-angle glaucoma or ocular hypertension, which underwent iStent inject W® implantation (Glaukos, Corporation, CA) between December 2018 and December 2022. Differences in intraocular pressure (IOP), the number of hypotensive eye drops used, and structural and functional tests were assessed between preoperative values and subsequent reviews during a follow-up period of one (n<!--> <!-->=<!--> <!-->98), two (n<!--> <!-->=<!--> <!-->55), and three years (n<!--> <!-->=<!--> <!-->15) after surgery.</div></div><div><h3>Results</h3><div>Among the 98 eyes studied, 85% were diagnosed with open-angle glaucoma (50% mild, 32% moderate, and 18% severe) and 15% with ocular hypertension. There was a statistically significant reduction in IOP compared to preoperative values for all visits except the 1-month (p<!--> <!-->=<!--> <!-->0.36) and 3-year (p<!--> <!-->=<!--> <!-->0.39) visits. Visual acuity increased from 0.39<!--> <!-->±<!--> <!-->0.25 to 0.72<!--> <!-->±<!--> <!-->0.24 (p&lt;<!--> <!-->0.01), considering that a significant portion of the interventions included cataract surgery. Before surgery, 66% of the sample used 2 or more hypotensive medications. Post-surgery, the number of hypotensive medications decreased (from 1.88<!--> <!-->±<!--> <!-->0.84 to 0.21<!--> <!-->±<!--> <!-->0.59 at 3 years) (p&lt;<!--> <!-->0.01), with an 88.9% reduction in the number of medications over three years. After surgery, 75% of cases did not require any medication.</div><div>Regarding structural and functional tests, thickness of retinal nerve fiber layers (RNFL (p<!--> <!-->=<!--> <!-->0.35), excavation / papilla ratio E/P (p<!--> <!-->=<!--> <!-->0.31), visual function index</div><div>(VFI (p<!--> <!-->=<!--> <!-->0.06), and deviation mean (MD (p<!--> <!-->=<!--> <!-->0.06) showed no statistically significant differences post-intervention. However, standard deviation of the pattern (DSM) did exhibit differences, decreasing from 5.46<!--> <!-->±<!--> <!-->4.03<!--> <!-->dB to 5.34<!--> <!-->±<!--> <!-->3.48<!--> <!-->dB (p<!--> <!-->=<!--> <!-->0.02).</div></div><div><h3>Conclusion</h3><div>The results of this study suggest that the iStent inject W® technique constitutes an effective and safe option for tension control and glaucoma treatment.</div></div>\",\"PeriodicalId\":8348,\"journal\":{\"name\":\"Archivos De La Sociedad Espanola De Oftalmologia\",\"volume\":\"99 11\",\"pages\":\"Pages 485-492\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archivos De La Sociedad Espanola De Oftalmologia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0365669124001163\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archivos De La Sociedad Espanola De Oftalmologia","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0365669124001163","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

材料和方法一项回顾性研究纳入了2018年12月至2022年12月期间接受iStent inject W® 植入术(Glaukos公司,加利福尼亚州)的98例开角型青光眼或眼压过高患者(57例男性,41例女性)。在术后一年(98 例)、两年(55 例)和三年(15 例)的随访期间,对术前值与后续复查值之间的眼压(IOP)差异、降压眼药水使用次数以及结构和功能测试进行了评估。与术前值相比,除1个月(p = 0.36)和3年(p = 0.39)检查外,所有检查的眼压均有统计学意义上的显著降低。考虑到相当一部分干预措施包括白内障手术,视力从 0.39 ± 0.25 提高到 0.72 ± 0.24(p< 0.01)。手术前,66% 的样本使用了 2 种或 2 种以上降压药物。手术后,降压药物的数量有所减少(从 1.88 ± 0.84 降至 3 年后的 0.21 ± 0.59)(p< 0.01),三年内药物数量减少了 88.9%。在结构和功能测试方面,视网膜神经纤维层厚度(RNFL)(p = 0.35)、挖空/乳头比率 E/P(p = 0.31)、视功能指数(VFI)(p = 0.06)和平均偏差(MD)(p = 0.06)在干预后无显著统计学差异。结论本研究结果表明,iStent inject W® 技术是控制眼压和治疗青光眼的有效而安全的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Análisis a tres años de resultados, seguridad y progresión en pacientes con glaucoma de ángulo abierto o hipertensión ocular, intervenidos de microcirugía trabecular

Aim

To evaluate the efficacy, safety, structural and functional progression following the insertion of iStent inject ® implants in patients with open-angle glaucoma or ocular hypertension at a tertiary-level hospital.

Materials and methods

A retrospective study included 98 eyes (57 males and 41 females) with open-angle glaucoma or ocular hypertension, which underwent iStent inject W® implantation (Glaukos, Corporation, CA) between December 2018 and December 2022. Differences in intraocular pressure (IOP), the number of hypotensive eye drops used, and structural and functional tests were assessed between preoperative values and subsequent reviews during a follow-up period of one (n = 98), two (n = 55), and three years (n = 15) after surgery.

Results

Among the 98 eyes studied, 85% were diagnosed with open-angle glaucoma (50% mild, 32% moderate, and 18% severe) and 15% with ocular hypertension. There was a statistically significant reduction in IOP compared to preoperative values for all visits except the 1-month (p = 0.36) and 3-year (p = 0.39) visits. Visual acuity increased from 0.39 ± 0.25 to 0.72 ± 0.24 (p< 0.01), considering that a significant portion of the interventions included cataract surgery. Before surgery, 66% of the sample used 2 or more hypotensive medications. Post-surgery, the number of hypotensive medications decreased (from 1.88 ± 0.84 to 0.21 ± 0.59 at 3 years) (p< 0.01), with an 88.9% reduction in the number of medications over three years. After surgery, 75% of cases did not require any medication.
Regarding structural and functional tests, thickness of retinal nerve fiber layers (RNFL (p = 0.35), excavation / papilla ratio E/P (p = 0.31), visual function index
(VFI (p = 0.06), and deviation mean (MD (p = 0.06) showed no statistically significant differences post-intervention. However, standard deviation of the pattern (DSM) did exhibit differences, decreasing from 5.46 ± 4.03 dB to 5.34 ± 3.48 dB (p = 0.02).

Conclusion

The results of this study suggest that the iStent inject W® technique constitutes an effective and safe option for tension control and glaucoma treatment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.20
自引率
0.00%
发文量
109
审稿时长
78 days
期刊介绍: La revista Archivos de la Sociedad Española de Oftalmología, editada mensualmente por la propia Sociedad, tiene como objetivo publicar trabajos de investigación básica y clínica como artículos originales; casos clínicos, innovaciones técnicas y correlaciones clinicopatológicas en forma de comunicaciones cortas; editoriales; revisiones; cartas al editor; comentarios de libros; información de eventos; noticias personales y anuncios comerciales, así como trabajos de temas históricos y motivos inconográficos relacionados con la Oftalmología. El título abreviado es Arch Soc Esp Oftalmol, y debe ser utilizado en bibliografías, notas a pie de página y referencias bibliográficas.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信