对湿热环境中旁观者胸外按压的疲劳、负荷和质量进行评估

IF 2.1 Q3 CRITICAL CARE MEDICINE
Haruka Takahashi , Kensuke Suzuki , Yohei Okada , Satoshi Harada , Hiroyuki Yokota , Marcus Eng Hock Ong , Satoo Ogawa
{"title":"对湿热环境中旁观者胸外按压的疲劳、负荷和质量进行评估","authors":"Haruka Takahashi ,&nbsp;Kensuke Suzuki ,&nbsp;Yohei Okada ,&nbsp;Satoshi Harada ,&nbsp;Hiroyuki Yokota ,&nbsp;Marcus Eng Hock Ong ,&nbsp;Satoo Ogawa","doi":"10.1016/j.resplu.2024.100818","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>This study aimed to investigate the physiological load on bystanders during cardiopulmonary resuscitation (CPR) and the quality of chest compressions in hot and humid environments.</div></div><div><h3>Methods</h3><div>This prospective experimental study compared the physical load and quality of chest compressions among healthy volunteers who performed 10 min chest compression in a climate chamber under normal conditions (for Tokyo) (Wet Bulb Globe Temperature [WBGT] 21 °C) and hot and humid conditions (WBGT 31 °C). The primary outcome was the depth of chest compressions over a 10-minute period. Secondary outcomes included the volunteer’s heart rate (HR), core body temperature (BT), Borg scale for assessing fatigue, and blood lactate levels. Data were analyzed using two-way repeated measures analysis of variance (ANOVA) and paired t-tests.</div></div><div><h3>Results</h3><div>Out of 31 participants, 29 participants (mean [SD] age: 21[0.7], male: 21 [70.5 %]) were included in the analysis. For WBGT 21 °C and 31 °C, the mean chest compression depth at 10 min was not statistically difference (the depth of chest compression: 52.2 mm and 51.5 mm (p = 0.52)). At 10 min, heart rate and core temperature were 126 vs. 143 bpm, and 37.4℃ vs. 37.5℃ for WBGT 21℃ vs. WBGT 31℃ (mean differences: 17 bpm [95 % CI: 7.7–26.3], 0.1℃ [95 % CI: −0.1–0.3]). At the end, Borg scale was 16 vs. 18 and lactate levels were 3.9 vs. 5.1 mmol/L (mean differences: 2 [95 % CI: 1–3], 1.2 mmol/L [95 % CI: 0.1–2.3]).</div></div><div><h3>Conclusion</h3><div>there was no significant difference in the depth of chest compression of paramedic students under the conditions between WBGT 31℃ and WBGT 21℃. For secondary outcomes, the lactate and fatigue of bystanders increased under WBGT 31℃ compared to WBGT 21℃. Further research is needed on CPR in hot and humid environments.</div></div>","PeriodicalId":94192,"journal":{"name":"Resuscitation plus","volume":"20 ","pages":"Article 100818"},"PeriodicalIF":2.1000,"publicationDate":"2024-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of fatigue, load and the quality of chest compressions by bystanders in hot and humid environments\",\"authors\":\"Haruka Takahashi ,&nbsp;Kensuke Suzuki ,&nbsp;Yohei Okada ,&nbsp;Satoshi Harada ,&nbsp;Hiroyuki Yokota ,&nbsp;Marcus Eng Hock Ong ,&nbsp;Satoo Ogawa\",\"doi\":\"10.1016/j.resplu.2024.100818\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>This study aimed to investigate the physiological load on bystanders during cardiopulmonary resuscitation (CPR) and the quality of chest compressions in hot and humid environments.</div></div><div><h3>Methods</h3><div>This prospective experimental study compared the physical load and quality of chest compressions among healthy volunteers who performed 10 min chest compression in a climate chamber under normal conditions (for Tokyo) (Wet Bulb Globe Temperature [WBGT] 21 °C) and hot and humid conditions (WBGT 31 °C). The primary outcome was the depth of chest compressions over a 10-minute period. Secondary outcomes included the volunteer’s heart rate (HR), core body temperature (BT), Borg scale for assessing fatigue, and blood lactate levels. Data were analyzed using two-way repeated measures analysis of variance (ANOVA) and paired t-tests.</div></div><div><h3>Results</h3><div>Out of 31 participants, 29 participants (mean [SD] age: 21[0.7], male: 21 [70.5 %]) were included in the analysis. For WBGT 21 °C and 31 °C, the mean chest compression depth at 10 min was not statistically difference (the depth of chest compression: 52.2 mm and 51.5 mm (p = 0.52)). At 10 min, heart rate and core temperature were 126 vs. 143 bpm, and 37.4℃ vs. 37.5℃ for WBGT 21℃ vs. WBGT 31℃ (mean differences: 17 bpm [95 % CI: 7.7–26.3], 0.1℃ [95 % CI: −0.1–0.3]). At the end, Borg scale was 16 vs. 18 and lactate levels were 3.9 vs. 5.1 mmol/L (mean differences: 2 [95 % CI: 1–3], 1.2 mmol/L [95 % CI: 0.1–2.3]).</div></div><div><h3>Conclusion</h3><div>there was no significant difference in the depth of chest compression of paramedic students under the conditions between WBGT 31℃ and WBGT 21℃. For secondary outcomes, the lactate and fatigue of bystanders increased under WBGT 31℃ compared to WBGT 21℃. Further research is needed on CPR in hot and humid environments.</div></div>\",\"PeriodicalId\":94192,\"journal\":{\"name\":\"Resuscitation plus\",\"volume\":\"20 \",\"pages\":\"Article 100818\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-10-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Resuscitation plus\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666520424002698\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CRITICAL CARE MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Resuscitation plus","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666520424002698","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

这项前瞻性实验研究比较了在正常条件(东京)(湿球温度 [WBGT] 21 °C)和湿热条件(WBGT 31 °C)下,健康志愿者在气候箱中进行 10 分钟胸外按压时的生理负荷和胸外按压的质量。主要结果是 10 分钟内胸外按压的深度。次要结果包括志愿者的心率(HR)、核心体温(BT)、用于评估疲劳的博格量表以及血液乳酸水平。采用双向重复测量方差分析(ANOVA)和配对 t 检验对数据进行了分析。WBGT 21 °C 和 31 °C 时,10 分钟的平均胸外按压深度没有统计学差异(胸外按压深度:52.2 mm 和 51.5 mm (p = 0.52))。10 分钟时,WBGT 21℃ 与 WBGT 31℃ 的心率和核心温度分别为 126 bpm 与 143 bpm,37.4℃ 与 37.5℃(平均差异:17 bpm [95 % CI:7.7-26.3],0.1℃ [95 % CI:-0.1-0.3])。结论:在 WBGT 31℃和 WBGT 21℃条件下,护理专业学生的胸外按压深度没有显著差异。在次要结果方面,与 WBGT 21℃相比,WBGT 31℃条件下旁观者的乳酸和疲劳程度有所增加。在湿热环境中进行心肺复苏还需要进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of fatigue, load and the quality of chest compressions by bystanders in hot and humid environments

Background

This study aimed to investigate the physiological load on bystanders during cardiopulmonary resuscitation (CPR) and the quality of chest compressions in hot and humid environments.

Methods

This prospective experimental study compared the physical load and quality of chest compressions among healthy volunteers who performed 10 min chest compression in a climate chamber under normal conditions (for Tokyo) (Wet Bulb Globe Temperature [WBGT] 21 °C) and hot and humid conditions (WBGT 31 °C). The primary outcome was the depth of chest compressions over a 10-minute period. Secondary outcomes included the volunteer’s heart rate (HR), core body temperature (BT), Borg scale for assessing fatigue, and blood lactate levels. Data were analyzed using two-way repeated measures analysis of variance (ANOVA) and paired t-tests.

Results

Out of 31 participants, 29 participants (mean [SD] age: 21[0.7], male: 21 [70.5 %]) were included in the analysis. For WBGT 21 °C and 31 °C, the mean chest compression depth at 10 min was not statistically difference (the depth of chest compression: 52.2 mm and 51.5 mm (p = 0.52)). At 10 min, heart rate and core temperature were 126 vs. 143 bpm, and 37.4℃ vs. 37.5℃ for WBGT 21℃ vs. WBGT 31℃ (mean differences: 17 bpm [95 % CI: 7.7–26.3], 0.1℃ [95 % CI: −0.1–0.3]). At the end, Borg scale was 16 vs. 18 and lactate levels were 3.9 vs. 5.1 mmol/L (mean differences: 2 [95 % CI: 1–3], 1.2 mmol/L [95 % CI: 0.1–2.3]).

Conclusion

there was no significant difference in the depth of chest compression of paramedic students under the conditions between WBGT 31℃ and WBGT 21℃. For secondary outcomes, the lactate and fatigue of bystanders increased under WBGT 31℃ compared to WBGT 21℃. Further research is needed on CPR in hot and humid environments.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Resuscitation plus
Resuscitation plus Critical Care and Intensive Care Medicine, Emergency Medicine
CiteScore
3.00
自引率
0.00%
发文量
0
审稿时长
52 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信