真空吸盘的仿生设计和吸附性能分析。

IF 3.4 3区 医学 Q1 ENGINEERING, MULTIDISCIPLINARY
Peng Xi, Yanqi Qiao, Xiaoyu Nie, Qian Cong
{"title":"真空吸盘的仿生设计和吸附性能分析。","authors":"Peng Xi, Yanqi Qiao, Xiaoyu Nie, Qian Cong","doi":"10.3390/biomimetics9100623","DOIUrl":null,"url":null,"abstract":"<p><p>This study addresses the problem that the traditional method is not effective in improving the adsorption performance of vacuum suckers. From the perspective of bionics, the adsorption performance of bionic suckers based on the excellent adsorption of the abalone abdominal foot was studied. A bionic sucker was designed by extracting the sealing ring structure of the abdominal foot tentacle. The bionic sucker was subjected to tensile experiments using an orthogonal experimental design, and the adsorption of the bionic sucker was simulated and analyzed to explore its adsorption mechanism. The results show that the primary and secondary factors affecting the adsorption of the sucker are the number of sealing rings, the width of sealing rings and the spacing of sealing rings. At 60% vacuum, the bionic sucker with two sealing rings, a 1.5 mm sealing ring width and 3 mm sealing ring spacing has the largest adsorption force, and its maximum adsorption force is 15.8% higher than that of the standard sucker. This study shows that the bionic sucker design can effectively improve the adsorption performance of the sucker. The bionic sucker had a different stress distribution on the sucker bottom, which resulted in greater Mises stress in the sealing ring and the surrounding area, while the Mises stress in the central area of the sucker was smaller.</p>","PeriodicalId":8907,"journal":{"name":"Biomimetics","volume":"9 10","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2024-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11506676/pdf/","citationCount":"0","resultStr":"{\"title\":\"Bionic Design and Adsorption Performance Analysis of Vacuum Suckers.\",\"authors\":\"Peng Xi, Yanqi Qiao, Xiaoyu Nie, Qian Cong\",\"doi\":\"10.3390/biomimetics9100623\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study addresses the problem that the traditional method is not effective in improving the adsorption performance of vacuum suckers. From the perspective of bionics, the adsorption performance of bionic suckers based on the excellent adsorption of the abalone abdominal foot was studied. A bionic sucker was designed by extracting the sealing ring structure of the abdominal foot tentacle. The bionic sucker was subjected to tensile experiments using an orthogonal experimental design, and the adsorption of the bionic sucker was simulated and analyzed to explore its adsorption mechanism. The results show that the primary and secondary factors affecting the adsorption of the sucker are the number of sealing rings, the width of sealing rings and the spacing of sealing rings. At 60% vacuum, the bionic sucker with two sealing rings, a 1.5 mm sealing ring width and 3 mm sealing ring spacing has the largest adsorption force, and its maximum adsorption force is 15.8% higher than that of the standard sucker. This study shows that the bionic sucker design can effectively improve the adsorption performance of the sucker. The bionic sucker had a different stress distribution on the sucker bottom, which resulted in greater Mises stress in the sealing ring and the surrounding area, while the Mises stress in the central area of the sucker was smaller.</p>\",\"PeriodicalId\":8907,\"journal\":{\"name\":\"Biomimetics\",\"volume\":\"9 10\",\"pages\":\"\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11506676/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomimetics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/biomimetics9100623\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomimetics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/biomimetics9100623","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

本研究解决了传统方法无法有效提高真空吸盘吸附性能的问题。从仿生学的角度出发,研究了基于鲍鱼腹足优良吸附性的仿生吸盘的吸附性能。通过提取鲍鱼腹足触手的密封环结构,设计了一种仿生吸盘。采用正交实验设计对仿生吸盘进行了拉伸实验,并对仿生吸盘的吸附情况进行了模拟和分析,以探索其吸附机理。结果表明,影响吸盘吸附的主要和次要因素是密封环的数量、密封环的宽度和密封环的间距。在 60% 的真空度下,具有两个密封环、密封环宽度为 1.5 毫米、密封环间距为 3 毫米的仿生吸盘的吸附力最大,其最大吸附力比标准吸盘高 15.8%。这项研究表明,仿生吸盘设计能有效提高吸盘的吸附性能。仿生吸盘在吸盘底部的应力分布不同,导致密封环和周围区域的米塞斯应力较大,而吸盘中心区域的米塞斯应力较小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Bionic Design and Adsorption Performance Analysis of Vacuum Suckers.

This study addresses the problem that the traditional method is not effective in improving the adsorption performance of vacuum suckers. From the perspective of bionics, the adsorption performance of bionic suckers based on the excellent adsorption of the abalone abdominal foot was studied. A bionic sucker was designed by extracting the sealing ring structure of the abdominal foot tentacle. The bionic sucker was subjected to tensile experiments using an orthogonal experimental design, and the adsorption of the bionic sucker was simulated and analyzed to explore its adsorption mechanism. The results show that the primary and secondary factors affecting the adsorption of the sucker are the number of sealing rings, the width of sealing rings and the spacing of sealing rings. At 60% vacuum, the bionic sucker with two sealing rings, a 1.5 mm sealing ring width and 3 mm sealing ring spacing has the largest adsorption force, and its maximum adsorption force is 15.8% higher than that of the standard sucker. This study shows that the bionic sucker design can effectively improve the adsorption performance of the sucker. The bionic sucker had a different stress distribution on the sucker bottom, which resulted in greater Mises stress in the sealing ring and the surrounding area, while the Mises stress in the central area of the sucker was smaller.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biomimetics
Biomimetics Biochemistry, Genetics and Molecular Biology-Biotechnology
CiteScore
3.50
自引率
11.10%
发文量
189
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信