Vertek 瞄准装置对计算机辅助马远端芝麻状骨钻孔手术准确性的影响--一项尸体实验研究。

IF 1.3 2区 农林科学 Q2 VETERINARY SCIENCES
Mathieu de Preux, Christina Precht, Andrea T Travaglini, Ljubo M Propadalo, Dima Farra, Beatriz Vidondo, Jeremiah T Easley, Christoph Koch
{"title":"Vertek 瞄准装置对计算机辅助马远端芝麻状骨钻孔手术准确性的影响--一项尸体实验研究。","authors":"Mathieu de Preux, Christina Precht, Andrea T Travaglini, Ljubo M Propadalo, Dima Farra, Beatriz Vidondo, Jeremiah T Easley, Christoph Koch","doi":"10.1111/vsu.14176","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To determine the effect of the Vertek aiming device (VAD) on the surgical accuracy of navigated drilling of the distal sesamoid bone (DSB).</p><p><strong>Study design: </strong>Experimental cadaveric study.</p><p><strong>Sample population: </strong>A total of 30 paired equine cadaveric limbs from 15 horses.</p><p><strong>Methods: </strong>Each specimen was placed in a purpose-built frame (PBF). Preoperative cone beam computed tomography (CBCT) images were acquired with an imaging unit coupled with a surgical navigation system. In the DSB of each specimen, a 4.5 mm glide hole and a 3.2 mm thread hole were drilled under navigation guidance, to simulate drilling for the repair of a mid-sagittal DSB fracture. In the VAD group navigated drilling was assisted by using the VAD. In the free-hand drilling group navigated drilling was performed without the VAD. Pre-and postoperative CBCT scans were merged and surgical accuracy aberrations (SAA) between the planned drill corridor and the created bone tunnel were measured. Descriptive statistics and repeated-measures analyses of variance (rep.-meas. ANOVA) were performed to compare SAA measurements between the study groups.</p><p><strong>Results: </strong>The SAA measurements ranged from 0 to 2.9 mm in the free-hand group and from 0 to 2.8 mm in the VAD group. The median overall SAA was lower in the VAD group than in the free-hand navigated group (0.6 mm ± [0.5-0.7] vs. 0.8 mm ± [0.7-1], rep.-meas. ANOVA p = .007).</p><p><strong>Conclusion: </strong>The additional use of the VAD in the described set-up for navigated drilling significantly improved surgical accuracy.</p><p><strong>Clinical significance: </strong>The combined use of the VAD and PBF may help improve surgical accuracy in navigated lag screw repair of DSB fractures.</p>","PeriodicalId":23667,"journal":{"name":"Veterinary Surgery","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of the Vertek aiming device on the surgical accuracy of computer-assisted drilling of the equine distal sesamoid bone-An experimental cadaveric study.\",\"authors\":\"Mathieu de Preux, Christina Precht, Andrea T Travaglini, Ljubo M Propadalo, Dima Farra, Beatriz Vidondo, Jeremiah T Easley, Christoph Koch\",\"doi\":\"10.1111/vsu.14176\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To determine the effect of the Vertek aiming device (VAD) on the surgical accuracy of navigated drilling of the distal sesamoid bone (DSB).</p><p><strong>Study design: </strong>Experimental cadaveric study.</p><p><strong>Sample population: </strong>A total of 30 paired equine cadaveric limbs from 15 horses.</p><p><strong>Methods: </strong>Each specimen was placed in a purpose-built frame (PBF). Preoperative cone beam computed tomography (CBCT) images were acquired with an imaging unit coupled with a surgical navigation system. In the DSB of each specimen, a 4.5 mm glide hole and a 3.2 mm thread hole were drilled under navigation guidance, to simulate drilling for the repair of a mid-sagittal DSB fracture. In the VAD group navigated drilling was assisted by using the VAD. In the free-hand drilling group navigated drilling was performed without the VAD. Pre-and postoperative CBCT scans were merged and surgical accuracy aberrations (SAA) between the planned drill corridor and the created bone tunnel were measured. Descriptive statistics and repeated-measures analyses of variance (rep.-meas. ANOVA) were performed to compare SAA measurements between the study groups.</p><p><strong>Results: </strong>The SAA measurements ranged from 0 to 2.9 mm in the free-hand group and from 0 to 2.8 mm in the VAD group. The median overall SAA was lower in the VAD group than in the free-hand navigated group (0.6 mm ± [0.5-0.7] vs. 0.8 mm ± [0.7-1], rep.-meas. ANOVA p = .007).</p><p><strong>Conclusion: </strong>The additional use of the VAD in the described set-up for navigated drilling significantly improved surgical accuracy.</p><p><strong>Clinical significance: </strong>The combined use of the VAD and PBF may help improve surgical accuracy in navigated lag screw repair of DSB fractures.</p>\",\"PeriodicalId\":23667,\"journal\":{\"name\":\"Veterinary Surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary Surgery\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1111/vsu.14176\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vsu.14176","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

研究目的确定Vertek瞄准装置(VAD)对远端芝麻状骨(DSB)导航钻孔手术准确性的影响:实验性尸体研究:研究设计:实验性尸体研究:每个标本都被放置在特制的框架(PBF)中。术前锥形束计算机断层扫描(CBCT)图像是通过与手术导航系统连接的成像装置获取的。在导航引导下,在每个标本的DSB上钻一个4.5毫米的滑行孔和一个3.2毫米的螺纹孔,以模拟修复中矢状DSB骨折的钻孔。在 VAD 组,使用 VAD 辅助导航钻孔。自由钻孔组则在不使用 VAD 的情况下进行导航钻孔。合并术前和术后的 CBCT 扫描图像,并测量计划钻孔走廊和创建的骨隧道之间的手术精度畸变(SAA)。通过描述性统计和重复测量方差分析(rep.-meas. ANOVA)来比较研究组之间的 SAA 测量值:结果:徒手组的 SAA 测量值从 0 到 2.9 毫米不等,VAD 组从 0 到 2.8 毫米不等。VAD组的总SAA中位数低于徒手导航组(0.6 mm ± [0.5-0.7] vs. 0.8 mm ± [0.7-1], rep.-meas. ANOVA p = .007):结论:在所述导航钻孔装置中额外使用 VAD 可显著提高手术准确性:临床意义:联合使用 VAD 和 PBF 可能有助于提高导航滞后螺钉修复 DSB 骨折的手术准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of the Vertek aiming device on the surgical accuracy of computer-assisted drilling of the equine distal sesamoid bone-An experimental cadaveric study.

Objective: To determine the effect of the Vertek aiming device (VAD) on the surgical accuracy of navigated drilling of the distal sesamoid bone (DSB).

Study design: Experimental cadaveric study.

Sample population: A total of 30 paired equine cadaveric limbs from 15 horses.

Methods: Each specimen was placed in a purpose-built frame (PBF). Preoperative cone beam computed tomography (CBCT) images were acquired with an imaging unit coupled with a surgical navigation system. In the DSB of each specimen, a 4.5 mm glide hole and a 3.2 mm thread hole were drilled under navigation guidance, to simulate drilling for the repair of a mid-sagittal DSB fracture. In the VAD group navigated drilling was assisted by using the VAD. In the free-hand drilling group navigated drilling was performed without the VAD. Pre-and postoperative CBCT scans were merged and surgical accuracy aberrations (SAA) between the planned drill corridor and the created bone tunnel were measured. Descriptive statistics and repeated-measures analyses of variance (rep.-meas. ANOVA) were performed to compare SAA measurements between the study groups.

Results: The SAA measurements ranged from 0 to 2.9 mm in the free-hand group and from 0 to 2.8 mm in the VAD group. The median overall SAA was lower in the VAD group than in the free-hand navigated group (0.6 mm ± [0.5-0.7] vs. 0.8 mm ± [0.7-1], rep.-meas. ANOVA p = .007).

Conclusion: The additional use of the VAD in the described set-up for navigated drilling significantly improved surgical accuracy.

Clinical significance: The combined use of the VAD and PBF may help improve surgical accuracy in navigated lag screw repair of DSB fractures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Veterinary Surgery
Veterinary Surgery 农林科学-兽医学
CiteScore
3.40
自引率
22.20%
发文量
162
审稿时长
8-16 weeks
期刊介绍: Veterinary Surgery, the official publication of the American College of Veterinary Surgeons and European College of Veterinary Surgeons, is a source of up-to-date coverage of surgical and anesthetic management of animals, addressing significant problems in veterinary surgery with relevant case histories and observations. It contains original, peer-reviewed articles that cover developments in veterinary surgery, and presents the most current review of the field, with timely articles on surgical techniques, diagnostic aims, care of infections, and advances in knowledge of metabolism as it affects the surgical patient. The journal places new developments in perspective, encompassing new concepts and peer commentary to help better understand and evaluate the surgical patient.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信