经颈动脉血流逆转用于脑动脉瘤夹重建过程中的近端控制:示例病例。

Nicole M Wenger, Matthew Hentschel, Ting I Wang, Kevin T Kim, Nicholas Caffes, Jacob Cherian
{"title":"经颈动脉血流逆转用于脑动脉瘤夹重建过程中的近端控制:示例病例。","authors":"Nicole M Wenger, Matthew Hentschel, Ting I Wang, Kevin T Kim, Nicholas Caffes, Jacob Cherian","doi":"10.3171/CASE24330","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Paraclinoid aneurysms can pose an operative challenge during clip reconstruction, given the complex surrounding anatomy and the aneurysmal tendency to maintain turgor despite standard approaches to proximal control. This report demonstrates the use of intraoperative retrograde arteriovenous shunting with the transcarotid artery revascularization (TCAR) system to assist in the safe clip reconstruction of an irregular paraclinoid aneurysm.</p><p><strong>Observations: </strong>A 33-year-old woman presented with perimesencephalic subarachnoid hemorrhage and was found to have an incidental 9-mm ophthalmic aneurysm. Coil embolization was not successful. During microsurgical clip reconstruction, the left common carotid artery was exposed to allow for proximal control as well as transcarotid arterial sheath placement. Flow reversal was instituted throughout the aneurysm dissection and clipping, with a visible softening of the aneurysm. Intraoperative angiography confirming successful clip reconstruction was performed utilizing the TCAR sheath. The case was complicated by the development of cerebrospinal fluid rhinorrhea postoperatively, requiring surgical repair. The patient has since made a complete recovery.</p><p><strong>Lessons: </strong>Transcarotid flow reversal utilizing the TCAR system has potential for use in the surgical treatment of paraclinoid aneurysms, as it may aid in softening the aneurysm for safer dissection and clip reconstruction, protect against aneurysm-associated emboli, and provide an avenue for intraoperative angiography. https://thejns.org/doi/10.3171/CASE24330.</p>","PeriodicalId":94098,"journal":{"name":"Journal of neurosurgery. Case lessons","volume":"8 16","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11488372/pdf/","citationCount":"0","resultStr":"{\"title\":\"Transcarotid flow reversal for proximal control during cerebral aneurysm clip reconstruction: illustrative case.\",\"authors\":\"Nicole M Wenger, Matthew Hentschel, Ting I Wang, Kevin T Kim, Nicholas Caffes, Jacob Cherian\",\"doi\":\"10.3171/CASE24330\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Paraclinoid aneurysms can pose an operative challenge during clip reconstruction, given the complex surrounding anatomy and the aneurysmal tendency to maintain turgor despite standard approaches to proximal control. This report demonstrates the use of intraoperative retrograde arteriovenous shunting with the transcarotid artery revascularization (TCAR) system to assist in the safe clip reconstruction of an irregular paraclinoid aneurysm.</p><p><strong>Observations: </strong>A 33-year-old woman presented with perimesencephalic subarachnoid hemorrhage and was found to have an incidental 9-mm ophthalmic aneurysm. Coil embolization was not successful. During microsurgical clip reconstruction, the left common carotid artery was exposed to allow for proximal control as well as transcarotid arterial sheath placement. Flow reversal was instituted throughout the aneurysm dissection and clipping, with a visible softening of the aneurysm. Intraoperative angiography confirming successful clip reconstruction was performed utilizing the TCAR sheath. The case was complicated by the development of cerebrospinal fluid rhinorrhea postoperatively, requiring surgical repair. The patient has since made a complete recovery.</p><p><strong>Lessons: </strong>Transcarotid flow reversal utilizing the TCAR system has potential for use in the surgical treatment of paraclinoid aneurysms, as it may aid in softening the aneurysm for safer dissection and clip reconstruction, protect against aneurysm-associated emboli, and provide an avenue for intraoperative angiography. https://thejns.org/doi/10.3171/CASE24330.</p>\",\"PeriodicalId\":94098,\"journal\":{\"name\":\"Journal of neurosurgery. Case lessons\",\"volume\":\"8 16\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11488372/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of neurosurgery. Case lessons\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3171/CASE24330\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neurosurgery. Case lessons","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3171/CASE24330","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:副夹层动脉瘤周围解剖结构复杂,尽管采用了标准的近端控制方法,但动脉瘤仍有保持充盈的趋势,因此在夹层重建过程中,副夹层动脉瘤可能会给手术带来挑战。本报告展示了使用经颈动脉再血管化(TCAR)系统进行术中逆行动静脉分流,以协助安全夹重建不规则的蛛网膜旁动脉瘤:一名 33 岁的女性因脑周蛛网膜下腔出血就诊,意外发现她患有 9 毫米的眼动脉瘤。线圈栓塞术没有成功。在显微手术夹重建过程中,暴露了左侧颈总动脉,以便进行近端控制和经颈动脉鞘置入。在动脉瘤剥离和夹闭的整个过程中都进行了血流逆转,动脉瘤明显变软。术中血管造影证实,利用 TCAR 鞘成功进行了夹子重建。术后出现脑脊液鼻出血,需要进行手术修补,使病例变得复杂。患者现已完全康复:https://thejns.org/doi/10.3171/CASE24330。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transcarotid flow reversal for proximal control during cerebral aneurysm clip reconstruction: illustrative case.

Background: Paraclinoid aneurysms can pose an operative challenge during clip reconstruction, given the complex surrounding anatomy and the aneurysmal tendency to maintain turgor despite standard approaches to proximal control. This report demonstrates the use of intraoperative retrograde arteriovenous shunting with the transcarotid artery revascularization (TCAR) system to assist in the safe clip reconstruction of an irregular paraclinoid aneurysm.

Observations: A 33-year-old woman presented with perimesencephalic subarachnoid hemorrhage and was found to have an incidental 9-mm ophthalmic aneurysm. Coil embolization was not successful. During microsurgical clip reconstruction, the left common carotid artery was exposed to allow for proximal control as well as transcarotid arterial sheath placement. Flow reversal was instituted throughout the aneurysm dissection and clipping, with a visible softening of the aneurysm. Intraoperative angiography confirming successful clip reconstruction was performed utilizing the TCAR sheath. The case was complicated by the development of cerebrospinal fluid rhinorrhea postoperatively, requiring surgical repair. The patient has since made a complete recovery.

Lessons: Transcarotid flow reversal utilizing the TCAR system has potential for use in the surgical treatment of paraclinoid aneurysms, as it may aid in softening the aneurysm for safer dissection and clip reconstruction, protect against aneurysm-associated emboli, and provide an avenue for intraoperative angiography. https://thejns.org/doi/10.3171/CASE24330.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信