双腔插管时选择性监测上腔静脉和下腔静脉引流量:在 CPB 侧放置近端接合点的潜在临床益处。

IF 1.1 4区 医学 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS
Ignazio Condello, Vincenzo Montemurro, Maria Grazia De Rosis, Giuseppe Nasso
{"title":"双腔插管时选择性监测上腔静脉和下腔静脉引流量:在 CPB 侧放置近端接合点的潜在临床益处。","authors":"Ignazio Condello, Vincenzo Montemurro, Maria Grazia De Rosis, Giuseppe Nasso","doi":"10.1177/02676591241295576","DOIUrl":null,"url":null,"abstract":"<p><p><i>Background:</i> In cardiac surgery, precision and efficiency are crucial, especially in managing venous drainage flows during complex procedures. This practical technique evaluates the benefits of placing the proximal junction on the cardiopulmonary bypass (CPB) side rather than on the surgical table in bicaval cannulation. Bicaval cannulation, involving both the superior vena cava (SVC) and inferior vena cava (IVC), ensures efficient venous return.<i>Practical technique:</i> Placing the junction on the CPB side allows for accurate, real-time control of venous drainage, allowing for swift responses to fluctuations and maintaining stable hemodynamics.<i>Perspectives:</i> This approach could minimize the risk of congestion in the liver, splanchnic system, and cerebral venous return, thereby preventing related complications. Another important potential benefit of this approach could be the ability to closely monitor and manage metabolic demands and oxygen consumption for SVC and IVC. Additionally, EmTec flow technology can be integrated for more precise management.</p>","PeriodicalId":49707,"journal":{"name":"Perfusion-Uk","volume":" ","pages":"2676591241295576"},"PeriodicalIF":1.1000,"publicationDate":"2024-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Selective monitoring of superior and inferior vena cava drainage flows in bicaval cannulation: Potential clinical benefits of proximal junction placement on the CPB side.\",\"authors\":\"Ignazio Condello, Vincenzo Montemurro, Maria Grazia De Rosis, Giuseppe Nasso\",\"doi\":\"10.1177/02676591241295576\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><i>Background:</i> In cardiac surgery, precision and efficiency are crucial, especially in managing venous drainage flows during complex procedures. This practical technique evaluates the benefits of placing the proximal junction on the cardiopulmonary bypass (CPB) side rather than on the surgical table in bicaval cannulation. Bicaval cannulation, involving both the superior vena cava (SVC) and inferior vena cava (IVC), ensures efficient venous return.<i>Practical technique:</i> Placing the junction on the CPB side allows for accurate, real-time control of venous drainage, allowing for swift responses to fluctuations and maintaining stable hemodynamics.<i>Perspectives:</i> This approach could minimize the risk of congestion in the liver, splanchnic system, and cerebral venous return, thereby preventing related complications. Another important potential benefit of this approach could be the ability to closely monitor and manage metabolic demands and oxygen consumption for SVC and IVC. Additionally, EmTec flow technology can be integrated for more precise management.</p>\",\"PeriodicalId\":49707,\"journal\":{\"name\":\"Perfusion-Uk\",\"volume\":\" \",\"pages\":\"2676591241295576\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Perfusion-Uk\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/02676591241295576\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Perfusion-Uk","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/02676591241295576","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:在心脏手术中,精确和高效至关重要,尤其是在复杂手术中管理静脉引流时。这项实用技术评估了在双腔静脉插管中将近端交界处放在心肺旁路(CPB)侧而不是手术台上的好处。双腔静脉插管涉及上腔静脉(SVC)和下腔静脉(IVC),可确保有效的静脉回流:实用技术:将交界处置于 CPB 一侧可准确、实时地控制静脉引流,从而对波动做出迅速反应并保持稳定的血液动力学:这种方法可将肝脏、脾脏系统和脑静脉回流充血的风险降至最低,从而预防相关并发症。这种方法的另一个重要潜在优势是能够密切监测和管理 SVC 和 IVC 的代谢需求和耗氧量。此外,还可以整合 EmTec 流量技术,进行更精确的管理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Selective monitoring of superior and inferior vena cava drainage flows in bicaval cannulation: Potential clinical benefits of proximal junction placement on the CPB side.

Background: In cardiac surgery, precision and efficiency are crucial, especially in managing venous drainage flows during complex procedures. This practical technique evaluates the benefits of placing the proximal junction on the cardiopulmonary bypass (CPB) side rather than on the surgical table in bicaval cannulation. Bicaval cannulation, involving both the superior vena cava (SVC) and inferior vena cava (IVC), ensures efficient venous return.Practical technique: Placing the junction on the CPB side allows for accurate, real-time control of venous drainage, allowing for swift responses to fluctuations and maintaining stable hemodynamics.Perspectives: This approach could minimize the risk of congestion in the liver, splanchnic system, and cerebral venous return, thereby preventing related complications. Another important potential benefit of this approach could be the ability to closely monitor and manage metabolic demands and oxygen consumption for SVC and IVC. Additionally, EmTec flow technology can be integrated for more precise management.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Perfusion-Uk
Perfusion-Uk 医学-外周血管病
CiteScore
3.00
自引率
8.30%
发文量
203
审稿时长
6-12 weeks
期刊介绍: Perfusion is an ISI-ranked, peer-reviewed scholarly journal, which provides current information on all aspects of perfusion, oxygenation and biocompatibility and their use in modern cardiac surgery. The journal is at the forefront of international research and development and presents an appropriately multidisciplinary approach to perfusion science.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信