内侧开放式楔形高胫骨截骨术与远端结节截骨术(使用或不使用前后螺钉)中胫骨后斜度的生物力学比较分析:一项使用猪胫骨进行的研究。

IF 1.8 Q2 ORTHOPEDICS
SICOT-J Pub Date : 2024-01-01 Epub Date: 2024-10-21 DOI:10.1051/sicotj/2024042
Yoshiya Nibe, Tsuneari Takahashi, Hironari Hai, Tomohiro Matsumura, Katsushi Takeshita
{"title":"内侧开放式楔形高胫骨截骨术与远端结节截骨术(使用或不使用前后螺钉)中胫骨后斜度的生物力学比较分析:一项使用猪胫骨进行的研究。","authors":"Yoshiya Nibe, Tsuneari Takahashi, Hironari Hai, Tomohiro Matsumura, Katsushi Takeshita","doi":"10.1051/sicotj/2024042","DOIUrl":null,"url":null,"abstract":"<p><p>Purpose While increased posterior tibial slope (PTS) is a concern post-medial open wedge high tibial osteotomy (MOWHTO), the ability of distal tuberosity osteotomy (DTO) to maintain postoperative PTS after cyclic loading remains unverified. This study aims to determine whether PTS alterations significantly differ between DTO and MOWHTO following cyclic loading.</p><p><strong>Methods: </strong>Biomechanical evaluations were conducted on thirty porcine tibias using MOWHTO and DTO, with and without an anterior-posterior (AP) screw. To investigate PTS changes, cyclic testing was carried out for MOWHTO and DTO. Displacement along the mechanical axis during cycles 10th, 100th, 500th, 1000th, 1500th and 2000th, variations in anterior and posterior gaps after 2000 cycles and increased PTS after 2000 cycles, were compared across the three groups. The displacement was evaluated by repeated-measures analysis of variance (ANOVA), and changes in AG and PG and increased PTS were evaluated by one-way ANOVA. The sample size for α and β errors were <0.05 and <0.20, and the effect size was 0.60 for one-way ANOVA and 0.46 for repeated-measures ANOVA.</p><p><strong>Results: </strong>There were no significant differences in displacement and anterior gap changes among the groups. A significant difference was observed in the posterior gap changes (P < 0.001) and increased PTS (P = 0.013) among the groups. Post hoc analysis indicated substantial disparities between MOWHTO and DTO without the AP screw (P = 0.035), as well as between MOWHTO and DTO with the AP screw (P = 0.021) concerning the increased PTS.</p><p><strong>Conclusion: </strong>After cyclic loading, MOWHTO exhibited a notably smaller PTS change than DTO regardless of the presence of an AP screw.</p>","PeriodicalId":46378,"journal":{"name":"SICOT-J","volume":"10 ","pages":"41"},"PeriodicalIF":1.8000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11492831/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparative biomechanical analysis of tibial posterior slope in medial open wedge high tibial osteotomy vs. distal tuberosity osteotomy with and without anterior-posterior screw: a study using porcine tibia.\",\"authors\":\"Yoshiya Nibe, Tsuneari Takahashi, Hironari Hai, Tomohiro Matsumura, Katsushi Takeshita\",\"doi\":\"10.1051/sicotj/2024042\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Purpose While increased posterior tibial slope (PTS) is a concern post-medial open wedge high tibial osteotomy (MOWHTO), the ability of distal tuberosity osteotomy (DTO) to maintain postoperative PTS after cyclic loading remains unverified. This study aims to determine whether PTS alterations significantly differ between DTO and MOWHTO following cyclic loading.</p><p><strong>Methods: </strong>Biomechanical evaluations were conducted on thirty porcine tibias using MOWHTO and DTO, with and without an anterior-posterior (AP) screw. To investigate PTS changes, cyclic testing was carried out for MOWHTO and DTO. Displacement along the mechanical axis during cycles 10th, 100th, 500th, 1000th, 1500th and 2000th, variations in anterior and posterior gaps after 2000 cycles and increased PTS after 2000 cycles, were compared across the three groups. The displacement was evaluated by repeated-measures analysis of variance (ANOVA), and changes in AG and PG and increased PTS were evaluated by one-way ANOVA. The sample size for α and β errors were <0.05 and <0.20, and the effect size was 0.60 for one-way ANOVA and 0.46 for repeated-measures ANOVA.</p><p><strong>Results: </strong>There were no significant differences in displacement and anterior gap changes among the groups. A significant difference was observed in the posterior gap changes (P < 0.001) and increased PTS (P = 0.013) among the groups. Post hoc analysis indicated substantial disparities between MOWHTO and DTO without the AP screw (P = 0.035), as well as between MOWHTO and DTO with the AP screw (P = 0.021) concerning the increased PTS.</p><p><strong>Conclusion: </strong>After cyclic loading, MOWHTO exhibited a notably smaller PTS change than DTO regardless of the presence of an AP screw.</p>\",\"PeriodicalId\":46378,\"journal\":{\"name\":\"SICOT-J\",\"volume\":\"10 \",\"pages\":\"41\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11492831/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SICOT-J\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1051/sicotj/2024042\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SICOT-J","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/sicotj/2024042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

目的 虽然胫骨后斜坡(PTS)增加是中轴开放式楔形高胫骨截骨术(MOWHTO)后的一个问题,但远端结节截骨术(DTO)在循环加载后维持术后PTS的能力仍未得到证实。本研究旨在确定 DTO 和 MOWHTO 在循环加载后的 PTS 变化是否存在显著差异:对使用 MOWHTO 和 DTO 的 30 头猪胫骨进行了生物力学评估,包括使用和不使用前后(AP)螺钉。为了研究 PTS 的变化,对 MOWHTO 和 DTO 进行了循环测试。比较了三组在第 10、100、500、1000、1500 和 2000 次循环期间沿机械轴的位移、2000 次循环后前后间隙的变化以及 2000 次循环后 PTS 的增加。位移采用重复测量方差分析(ANOVA)进行评估,AG 和 PG 的变化以及 PTS 的增加采用单因素方差分析进行评估。α和β误差的样本量均为 结果:各组间位移和前间隙变化无明显差异。在后间隙变化(P < 0.001)和 PTS 增加(P = 0.013)方面,观察到各组间存在明显差异。事后分析表明,在PTS增加方面,MOWHTO和不使用AP螺钉的DTO之间存在巨大差异(P = 0.035),MOWHTO和使用AP螺钉的DTO之间也存在巨大差异(P = 0.021):结论:在循环加载后,无论是否存在 AP 螺钉,MOWHTO 的 PTS 变化都明显小于 DTO。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative biomechanical analysis of tibial posterior slope in medial open wedge high tibial osteotomy vs. distal tuberosity osteotomy with and without anterior-posterior screw: a study using porcine tibia.

Purpose While increased posterior tibial slope (PTS) is a concern post-medial open wedge high tibial osteotomy (MOWHTO), the ability of distal tuberosity osteotomy (DTO) to maintain postoperative PTS after cyclic loading remains unverified. This study aims to determine whether PTS alterations significantly differ between DTO and MOWHTO following cyclic loading.

Methods: Biomechanical evaluations were conducted on thirty porcine tibias using MOWHTO and DTO, with and without an anterior-posterior (AP) screw. To investigate PTS changes, cyclic testing was carried out for MOWHTO and DTO. Displacement along the mechanical axis during cycles 10th, 100th, 500th, 1000th, 1500th and 2000th, variations in anterior and posterior gaps after 2000 cycles and increased PTS after 2000 cycles, were compared across the three groups. The displacement was evaluated by repeated-measures analysis of variance (ANOVA), and changes in AG and PG and increased PTS were evaluated by one-way ANOVA. The sample size for α and β errors were <0.05 and <0.20, and the effect size was 0.60 for one-way ANOVA and 0.46 for repeated-measures ANOVA.

Results: There were no significant differences in displacement and anterior gap changes among the groups. A significant difference was observed in the posterior gap changes (P < 0.001) and increased PTS (P = 0.013) among the groups. Post hoc analysis indicated substantial disparities between MOWHTO and DTO without the AP screw (P = 0.035), as well as between MOWHTO and DTO with the AP screw (P = 0.021) concerning the increased PTS.

Conclusion: After cyclic loading, MOWHTO exhibited a notably smaller PTS change than DTO regardless of the presence of an AP screw.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
SICOT-J
SICOT-J ORTHOPEDICS-
CiteScore
3.20
自引率
12.50%
发文量
44
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信