前臂旋转时,桡骨头形态在近端桡尺关节一致性中的作用。

IF 2 Q2 ORTHOPEDICS
Hailong Zhang, Guang Yang, Yi Lu
{"title":"前臂旋转时,桡骨头形态在近端桡尺关节一致性中的作用。","authors":"Hailong Zhang,&nbsp;Guang Yang,&nbsp;Yi Lu","doi":"10.1002/jeo2.70059","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>Congruency of the proximal radioulnar joint (PRUJ) is important in the rotation of the forearm while any compromise would significantly impair the elbow function. The purpose of this study is to determine the morphological features of the radial head and investigate its role in the congruency of the PRUJ during forearm rotation. The hypothesis is that the PRUJ is more congruent in the maximal pronation and supination positions than in the neutral position.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Thirty sets of computed tomography images of the elbow were acquired, and a three-dimensional model of the proximal radius and ulna was generated. The radius of curvature of the radial head and the radial head at the maximal pronation, neutral positions and maximal supination were calculated and compared with a one-way analysis of variance.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The point on the radial head contacting the middle point of radial head at the maximal pronation and supination was located at the ends of the semi-major axis of the ellipse, while it was located at one end of the semi-minor axis at neutral position. The radii of curvature of the pronation, neutral and supination points of the radial head were 14.72 ± 1.51, 9.74 ± 1.49 and 14.58 ± 1.70 mm, respectively. The value of the neutral point was significantly smaller than that of the pronation and supination points.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>This study quantitatively evaluated the morphology of the radial head and suggested that the best congruency of the PRUJ was achieved at maximal pronation and supination, while the neutral position was associated with the least congruency.</p>\n </section>\n \n <section>\n \n <h3> Level of Evidence</h3>\n \n <p>Basic Science Study.</p>\n </section>\n </div>","PeriodicalId":36909,"journal":{"name":"Journal of Experimental Orthopaedics","volume":"11 4","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11491982/pdf/","citationCount":"0","resultStr":"{\"title\":\"The role of radial head morphology in proximal radioulnar joint congruency during forearm rotation\",\"authors\":\"Hailong Zhang,&nbsp;Guang Yang,&nbsp;Yi Lu\",\"doi\":\"10.1002/jeo2.70059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Purpose</h3>\\n \\n <p>Congruency of the proximal radioulnar joint (PRUJ) is important in the rotation of the forearm while any compromise would significantly impair the elbow function. The purpose of this study is to determine the morphological features of the radial head and investigate its role in the congruency of the PRUJ during forearm rotation. The hypothesis is that the PRUJ is more congruent in the maximal pronation and supination positions than in the neutral position.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>Thirty sets of computed tomography images of the elbow were acquired, and a three-dimensional model of the proximal radius and ulna was generated. The radius of curvature of the radial head and the radial head at the maximal pronation, neutral positions and maximal supination were calculated and compared with a one-way analysis of variance.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>The point on the radial head contacting the middle point of radial head at the maximal pronation and supination was located at the ends of the semi-major axis of the ellipse, while it was located at one end of the semi-minor axis at neutral position. The radii of curvature of the pronation, neutral and supination points of the radial head were 14.72 ± 1.51, 9.74 ± 1.49 and 14.58 ± 1.70 mm, respectively. The value of the neutral point was significantly smaller than that of the pronation and supination points.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>This study quantitatively evaluated the morphology of the radial head and suggested that the best congruency of the PRUJ was achieved at maximal pronation and supination, while the neutral position was associated with the least congruency.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Level of Evidence</h3>\\n \\n <p>Basic Science Study.</p>\\n </section>\\n </div>\",\"PeriodicalId\":36909,\"journal\":{\"name\":\"Journal of Experimental Orthopaedics\",\"volume\":\"11 4\",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11491982/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Experimental Orthopaedics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jeo2.70059\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Experimental Orthopaedics","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jeo2.70059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:桡尺关节近端(PRUJ)的一致性对前臂的旋转非常重要,任何损伤都会严重影响肘关节的功能。本研究的目的是确定桡骨头的形态特征,并研究其在前臂旋转过程中对桡勾关节一致性的作用。研究假设:与中立位相比,PRUJ在最大代偿位和上举位时更为一致:方法:采集了 30 组肘部计算机断层扫描图像,并生成了桡骨和尺骨近端的三维模型。计算了桡骨头的曲率半径和桡骨头在最大代偿位、中立位和最大上举位时的曲率半径,并通过单因素方差分析进行了比较:结果:在最大匀称位和最大仰卧位时,桡骨头与桡骨头中点的接触点位于椭圆半主轴的两端,而在中立位时则位于半小轴的一端。桡骨头的前屈、中立和上屈点的曲率半径分别为(14.72 ± 1.51)、(9.74 ± 1.49)和(14.58 ± 1.70)毫米。中立点的数值明显小于前屈和上屈点:这项研究对桡骨头的形态进行了定量评估,结果表明,PRUJ在最大前伸和上举时的同轴度最好,而中立位的同轴度最小:基础科学研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

The role of radial head morphology in proximal radioulnar joint congruency during forearm rotation

The role of radial head morphology in proximal radioulnar joint congruency during forearm rotation

Purpose

Congruency of the proximal radioulnar joint (PRUJ) is important in the rotation of the forearm while any compromise would significantly impair the elbow function. The purpose of this study is to determine the morphological features of the radial head and investigate its role in the congruency of the PRUJ during forearm rotation. The hypothesis is that the PRUJ is more congruent in the maximal pronation and supination positions than in the neutral position.

Methods

Thirty sets of computed tomography images of the elbow were acquired, and a three-dimensional model of the proximal radius and ulna was generated. The radius of curvature of the radial head and the radial head at the maximal pronation, neutral positions and maximal supination were calculated and compared with a one-way analysis of variance.

Results

The point on the radial head contacting the middle point of radial head at the maximal pronation and supination was located at the ends of the semi-major axis of the ellipse, while it was located at one end of the semi-minor axis at neutral position. The radii of curvature of the pronation, neutral and supination points of the radial head were 14.72 ± 1.51, 9.74 ± 1.49 and 14.58 ± 1.70 mm, respectively. The value of the neutral point was significantly smaller than that of the pronation and supination points.

Conclusions

This study quantitatively evaluated the morphology of the radial head and suggested that the best congruency of the PRUJ was achieved at maximal pronation and supination, while the neutral position was associated with the least congruency.

Level of Evidence

Basic Science Study.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Experimental Orthopaedics
Journal of Experimental Orthopaedics Medicine-Orthopedics and Sports Medicine
CiteScore
3.20
自引率
5.60%
发文量
114
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信