Thais Cabral de Oliveira, Guilherme Andraus Bispo, Laura Beatriz de Socorro Poleto, Francisco Dantas de Maio Martinez, Max Túlio Rocha de Souza, Lais Calazans Menescal Linhares, Marilda Onghero Taffarel, Wagner Luís Ferreira, E Paulo Sérgio Patto Dos Santos
{"title":"通过超声心动图评估健康犬在异丙酚麻醉诱导过程中的血流动力学。","authors":"Thais Cabral de Oliveira, Guilherme Andraus Bispo, Laura Beatriz de Socorro Poleto, Francisco Dantas de Maio Martinez, Max Túlio Rocha de Souza, Lais Calazans Menescal Linhares, Marilda Onghero Taffarel, Wagner Luís Ferreira, E Paulo Sérgio Patto Dos Santos","doi":"10.1155/2024/5541917","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> Propofol is an intravenous anesthetic administered as a bolus or continuous infusion during anesthetic induction and maintenance. Its pharmacokinetic characteristics include hepatic and extrahepatic metabolism with a rapid onset of action and short duration, which provides a smooth anesthetic induction without excitatory effects. <b>Objective:</b> To evaluate whether the isolated use of propofol in anesthetic induction in dogs changes the hemodynamic variables assessed via echocardiography. <b>Study Design:</b> Prospective clinical study. <b>Animals:</b> Twelve healthy dogs. <b>Methods:</b> The dogs were induced with propofol (dose/effect) at 3 mg/kg/minute, and echocardiographic evaluations were performed immediately before anesthetic induction (MB) and immediately after its interruption (MI), at the end of the supply of the anesthetic agent. <b>Results:</b> A significant reduction was observed between the values of the following hemodynamic variables: Ejection Fraction (EF%), which varied from 70% to 65% (<i>p</i>=0.011) between moments, and the Doppler Ejection Index (DEI), which ranged from 27.1 mL/beat/m<sup>2</sup> to 22.4 mL/beat/m<sup>2</sup> (<i>p</i>=0.044). The heart rate (HR) and the other studied hemodynamic variables showed no significant differences between the evaluated moments. <b>Conclusion and Clinical Relevance:</b> Propofol was a safe anesthetic-inducing agent, maintaining stable hemodynamic indices during anesthetic induction at the used rate.</p>","PeriodicalId":23503,"journal":{"name":"Veterinary Medicine International","volume":"2024 ","pages":"5541917"},"PeriodicalIF":1.9000,"publicationDate":"2024-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11490346/pdf/","citationCount":"0","resultStr":"{\"title\":\"Hemodynamic Assessment via Echocardiography During Propofol Anesthetic Induction in Healthy Dogs.\",\"authors\":\"Thais Cabral de Oliveira, Guilherme Andraus Bispo, Laura Beatriz de Socorro Poleto, Francisco Dantas de Maio Martinez, Max Túlio Rocha de Souza, Lais Calazans Menescal Linhares, Marilda Onghero Taffarel, Wagner Luís Ferreira, E Paulo Sérgio Patto Dos Santos\",\"doi\":\"10.1155/2024/5541917\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Introduction:</b> Propofol is an intravenous anesthetic administered as a bolus or continuous infusion during anesthetic induction and maintenance. Its pharmacokinetic characteristics include hepatic and extrahepatic metabolism with a rapid onset of action and short duration, which provides a smooth anesthetic induction without excitatory effects. <b>Objective:</b> To evaluate whether the isolated use of propofol in anesthetic induction in dogs changes the hemodynamic variables assessed via echocardiography. <b>Study Design:</b> Prospective clinical study. <b>Animals:</b> Twelve healthy dogs. <b>Methods:</b> The dogs were induced with propofol (dose/effect) at 3 mg/kg/minute, and echocardiographic evaluations were performed immediately before anesthetic induction (MB) and immediately after its interruption (MI), at the end of the supply of the anesthetic agent. <b>Results:</b> A significant reduction was observed between the values of the following hemodynamic variables: Ejection Fraction (EF%), which varied from 70% to 65% (<i>p</i>=0.011) between moments, and the Doppler Ejection Index (DEI), which ranged from 27.1 mL/beat/m<sup>2</sup> to 22.4 mL/beat/m<sup>2</sup> (<i>p</i>=0.044). The heart rate (HR) and the other studied hemodynamic variables showed no significant differences between the evaluated moments. <b>Conclusion and Clinical Relevance:</b> Propofol was a safe anesthetic-inducing agent, maintaining stable hemodynamic indices during anesthetic induction at the used rate.</p>\",\"PeriodicalId\":23503,\"journal\":{\"name\":\"Veterinary Medicine International\",\"volume\":\"2024 \",\"pages\":\"5541917\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-10-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11490346/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary Medicine International\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2024/5541917\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Medicine International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2024/5541917","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
Hemodynamic Assessment via Echocardiography During Propofol Anesthetic Induction in Healthy Dogs.
Introduction: Propofol is an intravenous anesthetic administered as a bolus or continuous infusion during anesthetic induction and maintenance. Its pharmacokinetic characteristics include hepatic and extrahepatic metabolism with a rapid onset of action and short duration, which provides a smooth anesthetic induction without excitatory effects. Objective: To evaluate whether the isolated use of propofol in anesthetic induction in dogs changes the hemodynamic variables assessed via echocardiography. Study Design: Prospective clinical study. Animals: Twelve healthy dogs. Methods: The dogs were induced with propofol (dose/effect) at 3 mg/kg/minute, and echocardiographic evaluations were performed immediately before anesthetic induction (MB) and immediately after its interruption (MI), at the end of the supply of the anesthetic agent. Results: A significant reduction was observed between the values of the following hemodynamic variables: Ejection Fraction (EF%), which varied from 70% to 65% (p=0.011) between moments, and the Doppler Ejection Index (DEI), which ranged from 27.1 mL/beat/m2 to 22.4 mL/beat/m2 (p=0.044). The heart rate (HR) and the other studied hemodynamic variables showed no significant differences between the evaluated moments. Conclusion and Clinical Relevance: Propofol was a safe anesthetic-inducing agent, maintaining stable hemodynamic indices during anesthetic induction at the used rate.
期刊介绍:
Veterinary Medicine International is a peer-reviewed, Open Access journal that publishes original research articles and review articles in all areas of veterinary research. The journal will consider articles on the biological basis of disease, as well as diagnosis, prevention, treatment, and epidemiology.