后种植体修复体的尺寸与冠内悬臂和咬合力的关系:体外研究。

IF 3.2 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Panagoula Tzanetou, Stefanos Kourtis, Dimokritos Papalexopoulos, Nikitas Sykaras
{"title":"后种植体修复体的尺寸与冠内悬臂和咬合力的关系:体外研究。","authors":"Panagoula Tzanetou, Stefanos Kourtis, Dimokritos Papalexopoulos, Nikitas Sykaras","doi":"10.1111/jerd.13343","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of the present study was to investigate the relation of the implant position to the implant crown and analyze the location and magnitude of bite force.</p><p><strong>Materials and methods: </strong>The dimensions of 49 posterior implant-supported restorations were recorded in terms of: 1. implant diameter, 2. crown length, 3. crown width, 4. crown height, 5. occlusal surface of the restoration. The crown/implant height was measured and the distance between the implant center and the restoration center revealed the size of intra-coronal cantilevers. The occlusal force analysis determined the point and magnitude of loading. Correlation coefficient r was used for the statistical process and statistical control was carried out with the aid of t-test with minimum level of significance p < 0.05.</p><p><strong>Results: </strong>- The mean crown-to-implant ratio was 0.9 and in short implants (< 10mm) the ratio was 1.28. - Intra-coronal cantilever extensions ranged from 2.1 mm to 6.35 mm depending on crown size. - Occlusal loading was identified in cantilever areas of the crown.</p><p><strong>Conclusions: </strong>- Implant center deviates from crown center in 71%-82% of the cases depending on site location. - Implants with non-ideal position may support a functionally occluding crown.</p><p><strong>Clinical significance: </strong>Intra-coronal cantilevers are a critical factor to avoid clinical complications and should be taken under consideration both in the planning and fabrication phase of implant restorations.</p>","PeriodicalId":15988,"journal":{"name":"Journal of Esthetic and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dimensions of Posterior Implant Restorations Related to Intra-Coronal Cantilever and Occlusal Forces: An In Vitro Study.\",\"authors\":\"Panagoula Tzanetou, Stefanos Kourtis, Dimokritos Papalexopoulos, Nikitas Sykaras\",\"doi\":\"10.1111/jerd.13343\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The aim of the present study was to investigate the relation of the implant position to the implant crown and analyze the location and magnitude of bite force.</p><p><strong>Materials and methods: </strong>The dimensions of 49 posterior implant-supported restorations were recorded in terms of: 1. implant diameter, 2. crown length, 3. crown width, 4. crown height, 5. occlusal surface of the restoration. The crown/implant height was measured and the distance between the implant center and the restoration center revealed the size of intra-coronal cantilevers. The occlusal force analysis determined the point and magnitude of loading. Correlation coefficient r was used for the statistical process and statistical control was carried out with the aid of t-test with minimum level of significance p < 0.05.</p><p><strong>Results: </strong>- The mean crown-to-implant ratio was 0.9 and in short implants (< 10mm) the ratio was 1.28. - Intra-coronal cantilever extensions ranged from 2.1 mm to 6.35 mm depending on crown size. - Occlusal loading was identified in cantilever areas of the crown.</p><p><strong>Conclusions: </strong>- Implant center deviates from crown center in 71%-82% of the cases depending on site location. - Implants with non-ideal position may support a functionally occluding crown.</p><p><strong>Clinical significance: </strong>Intra-coronal cantilevers are a critical factor to avoid clinical complications and should be taken under consideration both in the planning and fabrication phase of implant restorations.</p>\",\"PeriodicalId\":15988,\"journal\":{\"name\":\"Journal of Esthetic and Restorative Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Esthetic and Restorative Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/jerd.13343\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Esthetic and Restorative Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jerd.13343","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在调查种植体位置与种植体牙冠的关系,分析咬合力的位置和大小:记录 49 个后种植体支持修复体的尺寸,包括:1:1.种植体直径;2.牙冠长度;3.牙冠宽度;4.牙冠高度;5.修复体的咬合面。测量了牙冠/种植体高度,种植体中心与修复体中心之间的距离显示了冠内悬臂的大小。咬合力分析确定了加载点和加载幅度。统计过程采用相关系数 r,统计控制采用 t 检验,最小显著性水平为 p 结果:- 牙冠与种植体的平均比值为 0.9,短种植体的比值为 0.9(结论:种植体中心偏离牙冠中心的比值为 0.9):- 种植体中心偏离牙冠中心的比例为 71%-82%,具体取决于种植部位的位置。- 非理想位置的种植体可能会支撑功能性咬合的牙冠:临床意义:冠内悬臂是避免临床并发症的关键因素,在种植修复的规划和制作阶段都应加以考虑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dimensions of Posterior Implant Restorations Related to Intra-Coronal Cantilever and Occlusal Forces: An In Vitro Study.

Objective: The aim of the present study was to investigate the relation of the implant position to the implant crown and analyze the location and magnitude of bite force.

Materials and methods: The dimensions of 49 posterior implant-supported restorations were recorded in terms of: 1. implant diameter, 2. crown length, 3. crown width, 4. crown height, 5. occlusal surface of the restoration. The crown/implant height was measured and the distance between the implant center and the restoration center revealed the size of intra-coronal cantilevers. The occlusal force analysis determined the point and magnitude of loading. Correlation coefficient r was used for the statistical process and statistical control was carried out with the aid of t-test with minimum level of significance p < 0.05.

Results: - The mean crown-to-implant ratio was 0.9 and in short implants (< 10mm) the ratio was 1.28. - Intra-coronal cantilever extensions ranged from 2.1 mm to 6.35 mm depending on crown size. - Occlusal loading was identified in cantilever areas of the crown.

Conclusions: - Implant center deviates from crown center in 71%-82% of the cases depending on site location. - Implants with non-ideal position may support a functionally occluding crown.

Clinical significance: Intra-coronal cantilevers are a critical factor to avoid clinical complications and should be taken under consideration both in the planning and fabrication phase of implant restorations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Esthetic and Restorative Dentistry
Journal of Esthetic and Restorative Dentistry 医学-牙科与口腔外科
CiteScore
6.30
自引率
6.20%
发文量
124
审稿时长
>12 weeks
期刊介绍: The Journal of Esthetic and Restorative Dentistry (JERD) is the longest standing peer-reviewed journal devoted solely to advancing the knowledge and practice of esthetic dentistry. Its goal is to provide the very latest evidence-based information in the realm of contemporary interdisciplinary esthetic dentistry through high quality clinical papers, sound research reports and educational features. The range of topics covered in the journal includes: - Interdisciplinary esthetic concepts - Implants - Conservative adhesive restorations - Tooth Whitening - Prosthodontic materials and techniques - Dental materials - Orthodontic, periodontal and endodontic esthetics - Esthetics related research - Innovations in esthetics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信