{"title":"西班牙放射肿瘤学会(SEOR)头颈部课程中的观察者间差异。目前的轮廓培训是否足够?","authors":"Victor De La Llana MSc ,&nbsp;Fernando Mañeru PhD ,&nbsp;Julián Librero MSc ,&nbsp;Santiago Pellejero MSc ,&nbsp;Fernando Arias MD, PhD","doi":"10.1016/j.adro.2024.101591","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>External beam radiation therapy has grown significantly, incorporating advanced techniques like intensity modulation or stereotactic treatments, which enhance precision and accuracy. Nevertheless, variability in target volume delineation by radiation oncologists remains a challenge, influencing dose distribution. This study analyzes an online training course by the Spanish Society of Radiation Oncology, focusing on head and neck tumor contouring, to evaluate interobserver variability.</div></div><div><h3>Material and Methods</h3><div>Eight instructors provided clinical directives for 8 head and neck pathologies. Participants contoured structures using their own treatment planning systems, emphasizing gross tumor volume and high-, medium-, and low-risk clinical target volumes (CTV) contouring. Delineation variability was evaluated using the Dice similarity coefficient and volume relative change.</div></div><div><h3>Results</h3><div>The results reveal significant variability in contouring, with mean Dice similarity coefficient values ranging from 0.57 to 0.69. High-risk CTV demonstrated higher variability compared with medium-risk CTV. The presence of a gross tumor volume and supporting positron emission tomography/computed tomography or magnetic resonance imaging studies did not significantly improve the concordance. Parotid cases exhibited the greatest differences.</div></div><div><h3>Conclusions</h3><div>Despite the introduction of new automatic tools, this study points to the need for uniform contouring criteria. Training and standardization efforts are essential to enhance radiation therapy treatment consistency and quality.</div></div>","PeriodicalId":7390,"journal":{"name":"Advances in Radiation Oncology","volume":"9 11","pages":"Article 101591"},"PeriodicalIF":2.2000,"publicationDate":"2024-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Interobserver Variability in a Spanish Society of Radiation Oncology (SEOR) Head and Neck Course. Is Current Contouring Training Sufficient?\",\"authors\":\"Victor De La Llana MSc ,&nbsp;Fernando Mañeru PhD ,&nbsp;Julián Librero MSc ,&nbsp;Santiago Pellejero MSc ,&nbsp;Fernando Arias MD, PhD\",\"doi\":\"10.1016/j.adro.2024.101591\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Purpose</h3><div>External beam radiation therapy has grown significantly, incorporating advanced techniques like intensity modulation or stereotactic treatments, which enhance precision and accuracy. Nevertheless, variability in target volume delineation by radiation oncologists remains a challenge, influencing dose distribution. This study analyzes an online training course by the Spanish Society of Radiation Oncology, focusing on head and neck tumor contouring, to evaluate interobserver variability.</div></div><div><h3>Material and Methods</h3><div>Eight instructors provided clinical directives for 8 head and neck pathologies. Participants contoured structures using their own treatment planning systems, emphasizing gross tumor volume and high-, medium-, and low-risk clinical target volumes (CTV) contouring. Delineation variability was evaluated using the Dice similarity coefficient and volume relative change.</div></div><div><h3>Results</h3><div>The results reveal significant variability in contouring, with mean Dice similarity coefficient values ranging from 0.57 to 0.69. High-risk CTV demonstrated higher variability compared with medium-risk CTV. The presence of a gross tumor volume and supporting positron emission tomography/computed tomography or magnetic resonance imaging studies did not significantly improve the concordance. Parotid cases exhibited the greatest differences.</div></div><div><h3>Conclusions</h3><div>Despite the introduction of new automatic tools, this study points to the need for uniform contouring criteria. Training and standardization efforts are essential to enhance radiation therapy treatment consistency and quality.</div></div>\",\"PeriodicalId\":7390,\"journal\":{\"name\":\"Advances in Radiation Oncology\",\"volume\":\"9 11\",\"pages\":\"Article 101591\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-08-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Radiation Oncology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2452109424001544\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ONCOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2452109424001544","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的 体外射束放射治疗已取得了长足发展,并采用了强度调制或立体定向治疗等先进技术,从而提高了精确度和准确性。然而,放射肿瘤学家在靶区划分上的差异仍然是一个挑战,影响着剂量的分布。本研究分析了西班牙放射肿瘤学会(Spanish Society of Radiation Oncology)的在线培训课程,重点是头颈部肿瘤轮廓的绘制,以评估观察者之间的变异性。参与者使用自己的治疗计划系统进行结构轮廓描绘,强调肿瘤总体积和高、中、低风险临床目标体积(CTV)轮廓描绘。结果显示,轮廓描绘存在显著差异,平均 Dice 相似性系数值从 0.57 到 0.69 不等。与中危 CTV 相比,高危 CTV 的变异性更高。有肿瘤总体积和支持正电子发射断层扫描/计算机断层扫描或磁共振成像研究并不能显著提高一致性。结论尽管引入了新的自动工具,但本研究指出需要统一的轮廓标准。培训和标准化工作对于提高放射治疗的一致性和质量至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Interobserver Variability in a Spanish Society of Radiation Oncology (SEOR) Head and Neck Course. Is Current Contouring Training Sufficient?

Purpose

External beam radiation therapy has grown significantly, incorporating advanced techniques like intensity modulation or stereotactic treatments, which enhance precision and accuracy. Nevertheless, variability in target volume delineation by radiation oncologists remains a challenge, influencing dose distribution. This study analyzes an online training course by the Spanish Society of Radiation Oncology, focusing on head and neck tumor contouring, to evaluate interobserver variability.

Material and Methods

Eight instructors provided clinical directives for 8 head and neck pathologies. Participants contoured structures using their own treatment planning systems, emphasizing gross tumor volume and high-, medium-, and low-risk clinical target volumes (CTV) contouring. Delineation variability was evaluated using the Dice similarity coefficient and volume relative change.

Results

The results reveal significant variability in contouring, with mean Dice similarity coefficient values ranging from 0.57 to 0.69. High-risk CTV demonstrated higher variability compared with medium-risk CTV. The presence of a gross tumor volume and supporting positron emission tomography/computed tomography or magnetic resonance imaging studies did not significantly improve the concordance. Parotid cases exhibited the greatest differences.

Conclusions

Despite the introduction of new automatic tools, this study points to the need for uniform contouring criteria. Training and standardization efforts are essential to enhance radiation therapy treatment consistency and quality.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Advances in Radiation Oncology
Advances in Radiation Oncology Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
4.60
自引率
4.30%
发文量
208
审稿时长
98 days
期刊介绍: The purpose of Advances is to provide information for clinicians who use radiation therapy by publishing: Clinical trial reports and reanalyses. Basic science original reports. Manuscripts examining health services research, comparative and cost effectiveness research, and systematic reviews. Case reports documenting unusual problems and solutions. High quality multi and single institutional series, as well as other novel retrospective hypothesis generating series. Timely critical reviews on important topics in radiation oncology, such as side effects. Articles reporting the natural history of disease and patterns of failure, particularly as they relate to treatment volume delineation. Articles on safety and quality in radiation therapy. Essays on clinical experience. Articles on practice transformation in radiation oncology, in particular: Aspects of health policy that may impact the future practice of radiation oncology. How information technology, such as data analytics and systems innovations, will change radiation oncology practice. Articles on imaging as they relate to radiation therapy treatment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信