在一个有束状心室通路的病例中,副希氏起搏时出现了反常反应:机制是什么?

IF 2.2 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Debabrata Bera DM, Calambur Narasimhan, Sanjeev S Mukherjee, Ayan Kar DNB, Joyanta Ghosh DM
{"title":"在一个有束状心室通路的病例中,副希氏起搏时出现了反常反应:机制是什么?","authors":"Debabrata Bera DM,&nbsp;Calambur Narasimhan,&nbsp;Sanjeev S Mukherjee,&nbsp;Ayan Kar DNB,&nbsp;Joyanta Ghosh DM","doi":"10.1002/joa3.13133","DOIUrl":null,"url":null,"abstract":"<p>Causes of paradoxical response include Pure His capture and inadvertent intermittent direct atrial capture. In the index case , we postulate that the likely mechanism of paradoxical prolongation could be due to decrement in the AV node due to the shortening of HH interval which happened as a result of a narrower H + Vc beat <i>following a wider Vc beat during decremetal pacing output</i>.\n <figure>\n <div><picture>\n <source></source></picture><p></p>\n </div>\n </figure>\n </p>","PeriodicalId":15174,"journal":{"name":"Journal of Arrhythmia","volume":"40 5","pages":"1198-1201"},"PeriodicalIF":2.2000,"publicationDate":"2024-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.13133","citationCount":"0","resultStr":"{\"title\":\"Paradoxical response during Para-Hisian pacing in a case with fasciculo-ventricular pathway: What is the mechanism?\",\"authors\":\"Debabrata Bera DM,&nbsp;Calambur Narasimhan,&nbsp;Sanjeev S Mukherjee,&nbsp;Ayan Kar DNB,&nbsp;Joyanta Ghosh DM\",\"doi\":\"10.1002/joa3.13133\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Causes of paradoxical response include Pure His capture and inadvertent intermittent direct atrial capture. In the index case , we postulate that the likely mechanism of paradoxical prolongation could be due to decrement in the AV node due to the shortening of HH interval which happened as a result of a narrower H + Vc beat <i>following a wider Vc beat during decremetal pacing output</i>.\\n <figure>\\n <div><picture>\\n <source></source></picture><p></p>\\n </div>\\n </figure>\\n </p>\",\"PeriodicalId\":15174,\"journal\":{\"name\":\"Journal of Arrhythmia\",\"volume\":\"40 5\",\"pages\":\"1198-1201\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-08-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.13133\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Arrhythmia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/joa3.13133\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arrhythmia","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/joa3.13133","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

悖论反应的原因包括纯His捕获和不慎间歇性直接心房捕获。在指数病例中,我们推测悖论性延长的可能机制是由于房室结因 HH 间期缩短而减弱,而 HH 间期缩短的原因是在降速起搏输出过程中,在较宽的 Vc 搏动后出现了较窄的 H + Vc 搏动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Paradoxical response during Para-Hisian pacing in a case with fasciculo-ventricular pathway: What is the mechanism?

Paradoxical response during Para-Hisian pacing in a case with fasciculo-ventricular pathway: What is the mechanism?

Causes of paradoxical response include Pure His capture and inadvertent intermittent direct atrial capture. In the index case , we postulate that the likely mechanism of paradoxical prolongation could be due to decrement in the AV node due to the shortening of HH interval which happened as a result of a narrower H + Vc beat following a wider Vc beat during decremetal pacing output.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Arrhythmia
Journal of Arrhythmia CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
10.00%
发文量
127
审稿时长
45 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信