通过经食道超声心动图和斑点追踪成像评估左房阑尾功能,预测射频导管消融术后复发的心房颤动

IF 1.6 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Xinyu Hao, Wei Li, Qunying Zhang, Le Cao, Jinshu Wang, Ling Guo, Qiang Zhang
{"title":"通过经食道超声心动图和斑点追踪成像评估左房阑尾功能,预测射频导管消融术后复发的心房颤动","authors":"Xinyu Hao,&nbsp;Wei Li,&nbsp;Qunying Zhang,&nbsp;Le Cao,&nbsp;Jinshu Wang,&nbsp;Ling Guo,&nbsp;Qiang Zhang","doi":"10.1111/echo.15958","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objective</h3>\n \n <p>To predict recurring atrial fibrillation (AF) following radiofrequency catheter ablation by assessing the attributes of the left atrium and the left atrial (LA) appendage (LAA) using transesophageal echocardiography (TEE) and speckle tracking imaging.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>The structural and functional indices of the LA and LAA of 80 patients with AF who underwent preoperative transthoracic echocardiography and TEE were measured. Recurrence was recorded postoperatively at 3, 6, and 12 months. The independent determinants of recurring AF were identified by logistic regression, and their optimum cutoff values, sensitivity, and specificity were estimated from the receiver operating characteristic (ROC) curves.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The recurrent and nonrecurrent groups comprised 17 and 63 patients, respectively. The LA internal diameter, LA end-diastolic and end-systolic volumes, LAA length, diameter and area of the opening of the LAA, and LAA end-diastolic volume were higher in the recurrent group. The LA strain in the reservoir phase, the ejection fraction and filling velocity of the LAA, the LAA emptying velocity (LAAeV), and the LAA strain (LAAS) reduced considerably. Multifactorial regression analyses demonstrated that the LAAeV and LAAS were independent determinants of recurring AF. ROC curve analysis revealed that the LAAeV and LAAS predicted postoperative recurrence at 34.5 cm/s (area under the curve [AUC]: 0.954, sensitivity: 94.1%, and specificity: 92.1%) and 11.61% (AUC: 0.925, sensitivity: 82.4%, and specificity: 95.2%), respectively, while the AUC, sensitivity, and specificity of the combined predictors (LAAeV + LAAS) were 0.978, 94.1%, and 93.7%, respectively.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>The LAAeV and LAAS independently influenced the postoperative recurrence of AF.</p>\n </section>\n </div>","PeriodicalId":50558,"journal":{"name":"Echocardiography-A Journal of Cardiovascular Ultrasound and Allied Techniques","volume":"41 10","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessing Left Atrial Appendage Functions by Transesophageal Echocardiography and Speckle Tracking Imaging to Predict Recurring Atrial Fibrillation Post-Radiofrequency Catheter Ablation\",\"authors\":\"Xinyu Hao,&nbsp;Wei Li,&nbsp;Qunying Zhang,&nbsp;Le Cao,&nbsp;Jinshu Wang,&nbsp;Ling Guo,&nbsp;Qiang Zhang\",\"doi\":\"10.1111/echo.15958\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Objective</h3>\\n \\n <p>To predict recurring atrial fibrillation (AF) following radiofrequency catheter ablation by assessing the attributes of the left atrium and the left atrial (LA) appendage (LAA) using transesophageal echocardiography (TEE) and speckle tracking imaging.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>The structural and functional indices of the LA and LAA of 80 patients with AF who underwent preoperative transthoracic echocardiography and TEE were measured. Recurrence was recorded postoperatively at 3, 6, and 12 months. The independent determinants of recurring AF were identified by logistic regression, and their optimum cutoff values, sensitivity, and specificity were estimated from the receiver operating characteristic (ROC) curves.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>The recurrent and nonrecurrent groups comprised 17 and 63 patients, respectively. The LA internal diameter, LA end-diastolic and end-systolic volumes, LAA length, diameter and area of the opening of the LAA, and LAA end-diastolic volume were higher in the recurrent group. The LA strain in the reservoir phase, the ejection fraction and filling velocity of the LAA, the LAA emptying velocity (LAAeV), and the LAA strain (LAAS) reduced considerably. Multifactorial regression analyses demonstrated that the LAAeV and LAAS were independent determinants of recurring AF. ROC curve analysis revealed that the LAAeV and LAAS predicted postoperative recurrence at 34.5 cm/s (area under the curve [AUC]: 0.954, sensitivity: 94.1%, and specificity: 92.1%) and 11.61% (AUC: 0.925, sensitivity: 82.4%, and specificity: 95.2%), respectively, while the AUC, sensitivity, and specificity of the combined predictors (LAAeV + LAAS) were 0.978, 94.1%, and 93.7%, respectively.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>The LAAeV and LAAS independently influenced the postoperative recurrence of AF.</p>\\n </section>\\n </div>\",\"PeriodicalId\":50558,\"journal\":{\"name\":\"Echocardiography-A Journal of Cardiovascular Ultrasound and Allied Techniques\",\"volume\":\"41 10\",\"pages\":\"\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Echocardiography-A Journal of Cardiovascular Ultrasound and Allied Techniques\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/echo.15958\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Echocardiography-A Journal of Cardiovascular Ultrasound and Allied Techniques","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/echo.15958","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

目的 通过使用经食道超声心动图(TEE)和斑点追踪成像技术评估左心房和左心房(LA)阑尾(LAA)的属性,预测射频导管消融术后房颤(AF)的复发情况。 方法 对 80 名术前接受经胸超声心动图和 TEE 检查的房颤患者的 LA 和 LAA 结构和功能指数进行测量。记录了术后 3、6 和 12 个月的复发情况。通过逻辑回归确定了房颤复发的独立决定因素,并根据接收器操作特征曲线(ROC)估算了这些因素的最佳临界值、灵敏度和特异性。 结果 复发组和非复发组分别有 17 名和 63 名患者。复发组的 LA 内径、LA 舒张末期和收缩末期容积、LAA 长度、LAA 开口直径和面积以及 LAA 舒张末期容积均较高。LA在储血期的应变、LAA的射血分数和充盈速度、LAA排空速度(LAAeV)和LAA应变(LAAS)显著降低。多因素回归分析表明,LAAeV 和 LAAS 是房颤复发的独立决定因素。ROC 曲线分析显示,LAAeV 和 LAAS 预测术后复发率为 34.5 cm/s(曲线下面积 [AUC]:0.954,灵敏度:97%):0.954,灵敏度:94.1%,特异性:92.1%)和 11.61%(AUC:0.925,灵敏度:82.4%,特异性:95.2%),而联合预测因子(LAAeV + LAAS)的 AUC、灵敏度和特异性分别为 0.978、94.1% 和 93.7%。 结论 LAAeV 和 LAAS 对房颤术后复发有独立影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessing Left Atrial Appendage Functions by Transesophageal Echocardiography and Speckle Tracking Imaging to Predict Recurring Atrial Fibrillation Post-Radiofrequency Catheter Ablation

Objective

To predict recurring atrial fibrillation (AF) following radiofrequency catheter ablation by assessing the attributes of the left atrium and the left atrial (LA) appendage (LAA) using transesophageal echocardiography (TEE) and speckle tracking imaging.

Methods

The structural and functional indices of the LA and LAA of 80 patients with AF who underwent preoperative transthoracic echocardiography and TEE were measured. Recurrence was recorded postoperatively at 3, 6, and 12 months. The independent determinants of recurring AF were identified by logistic regression, and their optimum cutoff values, sensitivity, and specificity were estimated from the receiver operating characteristic (ROC) curves.

Results

The recurrent and nonrecurrent groups comprised 17 and 63 patients, respectively. The LA internal diameter, LA end-diastolic and end-systolic volumes, LAA length, diameter and area of the opening of the LAA, and LAA end-diastolic volume were higher in the recurrent group. The LA strain in the reservoir phase, the ejection fraction and filling velocity of the LAA, the LAA emptying velocity (LAAeV), and the LAA strain (LAAS) reduced considerably. Multifactorial regression analyses demonstrated that the LAAeV and LAAS were independent determinants of recurring AF. ROC curve analysis revealed that the LAAeV and LAAS predicted postoperative recurrence at 34.5 cm/s (area under the curve [AUC]: 0.954, sensitivity: 94.1%, and specificity: 92.1%) and 11.61% (AUC: 0.925, sensitivity: 82.4%, and specificity: 95.2%), respectively, while the AUC, sensitivity, and specificity of the combined predictors (LAAeV + LAAS) were 0.978, 94.1%, and 93.7%, respectively.

Conclusion

The LAAeV and LAAS independently influenced the postoperative recurrence of AF.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.40
自引率
6.70%
发文量
211
审稿时长
3-6 weeks
期刊介绍: Echocardiography: A Journal of Cardiovascular Ultrasound and Allied Techniques is the official publication of the International Society of Cardiovascular Ultrasound. Widely recognized for its comprehensive peer-reviewed articles, case studies, original research, and reviews by international authors. Echocardiography keeps its readership of echocardiographers, ultrasound specialists, and cardiologists well informed of the latest developments in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信