酸挑战前后不同抛光类型下通用复合材料的物理和机械性能分析

IF 1.9 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
International Journal of Dentistry Pub Date : 2024-02-29 eCollection Date: 2024-01-01 DOI:10.1155/2024/6817593
José Roberto Vergínio de Matos, Letícia Barbero Antunes, Isabela Araguê Catanoze, Isabela Saturnino de Souza, Paulo Henrique Dos Santos, Aimée Maria Guiotti
{"title":"酸挑战前后不同抛光类型下通用复合材料的物理和机械性能分析","authors":"José Roberto Vergínio de Matos, Letícia Barbero Antunes, Isabela Araguê Catanoze, Isabela Saturnino de Souza, Paulo Henrique Dos Santos, Aimée Maria Guiotti","doi":"10.1155/2024/6817593","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to evaluate in vitro the degree of surface smoothness provided by two different polishing techniques and the effect of acid challenge on the alteration of surface roughness (Ra), microhardness (Knoop), and color (<i>Δ</i>E<sub>00</sub>) of three nanoparticulate composites, simulating 1 year of exposure to hydrochloric acid (HCl). Eighty specimens for each composite were divided into four groups (<i>n</i> = 240), being control without polishing, control with wear, WPC (wear + polishing with Cosmedent Kit), and WPB (wear + BisCover LV liquid polish). Repeated measures ANOVA was applied for Ra and Knoop Microhardness. For the color (<i>Δ</i>E) three-way ANOVA was applied. In cases of statistically significant the Tukey posttest was applied (<i>α</i> = 0.05). Both types of polishing tested resulted in a surface smoothness below the critical value established by the studies (Ra ≥ 0.2 <i>μ</i>m), even after immersion. The microhardness of all composite resins decreased after the challenges. The specimens immersed in HCl showed a lower microhardness (42.2 Kgf/mm<sup>2</sup>) when compared to the specimens immersed in artificial saliva (44.7 Kgf/mm<sup>2</sup>). Regarding the color change, the composites presented values compatible with clinical acceptability, with a statistically significant difference only between the control group and the other types of polishing for the Z350 XT resin (<i>Δ</i>E<sub>00</sub> = 3.78). It was concluded that both mechanical and chemical polishing produced a satisfactory surface smoothness, even after immersions in artificial saliva and HCl. The microhardness of the composites was affected by the challenges and the composites tested were within clinical acceptability with regard to color change.</p>","PeriodicalId":13947,"journal":{"name":"International Journal of Dentistry","volume":"2024 ","pages":"6817593"},"PeriodicalIF":1.9000,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11458286/pdf/","citationCount":"0","resultStr":"{\"title\":\"Analysis of Physical and Mechanical Properties of Universal Composites under Different Types of Polishing before and after Acid Challenge.\",\"authors\":\"José Roberto Vergínio de Matos, Letícia Barbero Antunes, Isabela Araguê Catanoze, Isabela Saturnino de Souza, Paulo Henrique Dos Santos, Aimée Maria Guiotti\",\"doi\":\"10.1155/2024/6817593\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aimed to evaluate in vitro the degree of surface smoothness provided by two different polishing techniques and the effect of acid challenge on the alteration of surface roughness (Ra), microhardness (Knoop), and color (<i>Δ</i>E<sub>00</sub>) of three nanoparticulate composites, simulating 1 year of exposure to hydrochloric acid (HCl). Eighty specimens for each composite were divided into four groups (<i>n</i> = 240), being control without polishing, control with wear, WPC (wear + polishing with Cosmedent Kit), and WPB (wear + BisCover LV liquid polish). Repeated measures ANOVA was applied for Ra and Knoop Microhardness. For the color (<i>Δ</i>E) three-way ANOVA was applied. In cases of statistically significant the Tukey posttest was applied (<i>α</i> = 0.05). Both types of polishing tested resulted in a surface smoothness below the critical value established by the studies (Ra ≥ 0.2 <i>μ</i>m), even after immersion. The microhardness of all composite resins decreased after the challenges. The specimens immersed in HCl showed a lower microhardness (42.2 Kgf/mm<sup>2</sup>) when compared to the specimens immersed in artificial saliva (44.7 Kgf/mm<sup>2</sup>). Regarding the color change, the composites presented values compatible with clinical acceptability, with a statistically significant difference only between the control group and the other types of polishing for the Z350 XT resin (<i>Δ</i>E<sub>00</sub> = 3.78). It was concluded that both mechanical and chemical polishing produced a satisfactory surface smoothness, even after immersions in artificial saliva and HCl. The microhardness of the composites was affected by the challenges and the composites tested were within clinical acceptability with regard to color change.</p>\",\"PeriodicalId\":13947,\"journal\":{\"name\":\"International Journal of Dentistry\",\"volume\":\"2024 \",\"pages\":\"6817593\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-02-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11458286/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2024/6817593\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2024/6817593","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在体外评估两种不同抛光技术提供的表面光滑度,以及酸挑战对三种纳米颗粒复合材料表面粗糙度(Ra)、显微硬度(Knoop)和颜色(ΔE00)变化的影响,模拟暴露在盐酸(HCl)中 1 年的情况。每种复合材料的 80 个试样被分为四组(n = 240),分别是未抛光对照组、有磨损对照组、WPC(磨损 + 使用 Cosmedent Kit 进行抛光)和 WPB(磨损 + BisCover LV 液体抛光剂)。对 Ra 和努氏显微硬度进行了重复测量方差分析。对颜色(ΔE)采用了三方方差分析。在统计意义显著的情况下,采用 Tukey 后验(α = 0.05)。所测试的两种抛光方式都导致表面光滑度低于研究确定的临界值(Ra ≥ 0.2 μm),即使在浸泡之后也是如此。所有复合树脂的显微硬度在测试后都有所下降。与浸泡在人工唾液中的试样(44.7 Kgf/mm2)相比,浸泡在盐酸中的试样显微硬度较低(42.2 Kgf/mm2)。在颜色变化方面,复合材料的颜色值符合临床接受程度,只有 Z350 XT 树脂在对照组和其他抛光类型之间存在显著差异(ΔE00 = 3.78)。结论是,即使在人工唾液和盐酸中浸泡后,机械抛光和化学抛光都能产生令人满意的表面光滑度。复合材料的显微硬度受到挑战的影响,测试的复合材料的颜色变化在临床可接受范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of Physical and Mechanical Properties of Universal Composites under Different Types of Polishing before and after Acid Challenge.

This study aimed to evaluate in vitro the degree of surface smoothness provided by two different polishing techniques and the effect of acid challenge on the alteration of surface roughness (Ra), microhardness (Knoop), and color (ΔE00) of three nanoparticulate composites, simulating 1 year of exposure to hydrochloric acid (HCl). Eighty specimens for each composite were divided into four groups (n = 240), being control without polishing, control with wear, WPC (wear + polishing with Cosmedent Kit), and WPB (wear + BisCover LV liquid polish). Repeated measures ANOVA was applied for Ra and Knoop Microhardness. For the color (ΔE) three-way ANOVA was applied. In cases of statistically significant the Tukey posttest was applied (α = 0.05). Both types of polishing tested resulted in a surface smoothness below the critical value established by the studies (Ra ≥ 0.2 μm), even after immersion. The microhardness of all composite resins decreased after the challenges. The specimens immersed in HCl showed a lower microhardness (42.2 Kgf/mm2) when compared to the specimens immersed in artificial saliva (44.7 Kgf/mm2). Regarding the color change, the composites presented values compatible with clinical acceptability, with a statistically significant difference only between the control group and the other types of polishing for the Z350 XT resin (ΔE00 = 3.78). It was concluded that both mechanical and chemical polishing produced a satisfactory surface smoothness, even after immersions in artificial saliva and HCl. The microhardness of the composites was affected by the challenges and the composites tested were within clinical acceptability with regard to color change.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Dentistry
International Journal of Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.30
自引率
4.80%
发文量
219
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信