在前十字韧带重建术中,术前皮肤清洁与否对皮肤污染无明显差异。

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
Benjamin Bartek, Alexandra Völkner, Stephan Oehme, Stephen Fahy, Tobias Winkler, Tobias Jung
{"title":"在前十字韧带重建术中,术前皮肤清洁与否对皮肤污染无明显差异。","authors":"Benjamin Bartek, Alexandra Völkner, Stephan Oehme, Stephen Fahy, Tobias Winkler, Tobias Jung","doi":"10.1002/ksa.12476","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This prospective study aimed to assess whether preoperative antiseptic skin cleansing reduces bacterial contamination and surgical site infections (SSI) following anterior cruciate ligament reconstruction (ACLR). We hypothesized that antiseptic cleaning would lower bacterial load, reducing contamination and early infections.</p><p><strong>Methods: </strong>One hundred and nineteen patients scheduled for ACLR were included in this prospective, nonrandomized study. Individuals were divided into two groups. Patients in the intervention group applied octenisan® wash lotion daily for three days before surgery and used the wash solution instead of their usual shower gel. Additionally, they swiped their leg with octenisan® soaked gloves on the morning of the operation. The control group followed their usual wash routine with no specific instructions. Fluid samples were taken before surgery from the irrigation bag and at 15-min intervals from the reservoir of the sterile surgical drape during the procedure. Suture material used for the ACL graft and meniscus repair were also collected for testing. The samples were subjected to a 14-day incubation period. Follow-up included outpatient visits at 6 weeks, 12 weeks and 6 months with a final evaluation at 12 months.</p><p><strong>Results: </strong>Contamination rates showed no significant difference between the control and intervention groups. The mean contamination rate in the control group was 6.4% (n = 22) and 6.6% (n = 24) in the intervention group (p = 0.28). At 12-month follow-up, 110 out of 119 participants were included (52 control, 58 intervention). T tests for age (p = 0.19), BMI (p = 0.66), and surgery duration (p = 0.38) showed no significant differences. No early SSI were observed in either group postoperatively.</p><p><strong>Conclusion: </strong>Our results indicate that the use of antiseptic wash lotion and gloves does not influence the risk of bacterial contamination during surgery.</p><p><strong>Level of evidence: </strong>Level III.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"No significant difference in skin contamination during anterior cruciate ligament reconstruction with and without preoperative skin cleaning.\",\"authors\":\"Benjamin Bartek, Alexandra Völkner, Stephan Oehme, Stephen Fahy, Tobias Winkler, Tobias Jung\",\"doi\":\"10.1002/ksa.12476\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This prospective study aimed to assess whether preoperative antiseptic skin cleansing reduces bacterial contamination and surgical site infections (SSI) following anterior cruciate ligament reconstruction (ACLR). We hypothesized that antiseptic cleaning would lower bacterial load, reducing contamination and early infections.</p><p><strong>Methods: </strong>One hundred and nineteen patients scheduled for ACLR were included in this prospective, nonrandomized study. Individuals were divided into two groups. Patients in the intervention group applied octenisan® wash lotion daily for three days before surgery and used the wash solution instead of their usual shower gel. Additionally, they swiped their leg with octenisan® soaked gloves on the morning of the operation. The control group followed their usual wash routine with no specific instructions. Fluid samples were taken before surgery from the irrigation bag and at 15-min intervals from the reservoir of the sterile surgical drape during the procedure. Suture material used for the ACL graft and meniscus repair were also collected for testing. The samples were subjected to a 14-day incubation period. Follow-up included outpatient visits at 6 weeks, 12 weeks and 6 months with a final evaluation at 12 months.</p><p><strong>Results: </strong>Contamination rates showed no significant difference between the control and intervention groups. The mean contamination rate in the control group was 6.4% (n = 22) and 6.6% (n = 24) in the intervention group (p = 0.28). At 12-month follow-up, 110 out of 119 participants were included (52 control, 58 intervention). T tests for age (p = 0.19), BMI (p = 0.66), and surgery duration (p = 0.38) showed no significant differences. No early SSI were observed in either group postoperatively.</p><p><strong>Conclusion: </strong>Our results indicate that the use of antiseptic wash lotion and gloves does not influence the risk of bacterial contamination during surgery.</p><p><strong>Level of evidence: </strong>Level III.</p>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/ksa.12476\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/ksa.12476","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

目的:这项前瞻性研究旨在评估术前消毒皮肤清洁是否能减少前交叉韧带重建术(ACLR)后的细菌污染和手术部位感染(SSI)。我们假设抗菌清洁可降低细菌负荷,减少污染和早期感染:这项前瞻性非随机研究共纳入了 119 名计划接受前交叉韧带重建术的患者。患者被分为两组。干预组患者在术前三天每天使用 octenisan® 洗液,并用洗液代替常用的沐浴露。此外,他们还在手术当天早上用浸泡过octenisan®的手套擦拭腿部。对照组则按照平时的清洗程序进行清洗,没有特别说明。手术前从灌洗袋中抽取液体样本,手术过程中每隔 15 分钟从无菌手术巾的储液器中抽取液体样本。用于前交叉韧带移植和半月板修复的缝合材料也被收集起来进行检测。样本经过 14 天的培养期。随访包括 6 周、12 周和 6 个月时的门诊检查,以及 12 个月时的最终评估:结果:对照组和干预组的污染率无明显差异。对照组的平均污染率为 6.4%(n = 22),干预组为 6.6%(n = 24)(p = 0.28)。在为期 12 个月的随访中,119 名参与者中有 110 人(对照组 52 人,干预组 58 人)接受了随访。年龄(p = 0.19)、体重指数(p = 0.66)和手术持续时间(p = 0.38)的 T 检验显示无显著差异。两组术后均未观察到早期 SSI:结论:我们的研究结果表明,使用消毒洗液和手套不会影响手术中细菌污染的风险:证据等级:三级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
No significant difference in skin contamination during anterior cruciate ligament reconstruction with and without preoperative skin cleaning.

Purpose: This prospective study aimed to assess whether preoperative antiseptic skin cleansing reduces bacterial contamination and surgical site infections (SSI) following anterior cruciate ligament reconstruction (ACLR). We hypothesized that antiseptic cleaning would lower bacterial load, reducing contamination and early infections.

Methods: One hundred and nineteen patients scheduled for ACLR were included in this prospective, nonrandomized study. Individuals were divided into two groups. Patients in the intervention group applied octenisan® wash lotion daily for three days before surgery and used the wash solution instead of their usual shower gel. Additionally, they swiped their leg with octenisan® soaked gloves on the morning of the operation. The control group followed their usual wash routine with no specific instructions. Fluid samples were taken before surgery from the irrigation bag and at 15-min intervals from the reservoir of the sterile surgical drape during the procedure. Suture material used for the ACL graft and meniscus repair were also collected for testing. The samples were subjected to a 14-day incubation period. Follow-up included outpatient visits at 6 weeks, 12 weeks and 6 months with a final evaluation at 12 months.

Results: Contamination rates showed no significant difference between the control and intervention groups. The mean contamination rate in the control group was 6.4% (n = 22) and 6.6% (n = 24) in the intervention group (p = 0.28). At 12-month follow-up, 110 out of 119 participants were included (52 control, 58 intervention). T tests for age (p = 0.19), BMI (p = 0.66), and surgery duration (p = 0.38) showed no significant differences. No early SSI were observed in either group postoperatively.

Conclusion: Our results indicate that the use of antiseptic wash lotion and gloves does not influence the risk of bacterial contamination during surgery.

Level of evidence: Level III.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信