比较青光眼疑似患者和健康对照组的神经节细胞层厚度和模式视网膜电图。

IF 1.4 4区 医学 Q3 OPHTHALMOLOGY
Jayadev Nanda, Bhawesh Ch Saha, Amit Raj, Prabhakar Singh, Prerna Sinha
{"title":"比较青光眼疑似患者和健康对照组的神经节细胞层厚度和模式视网膜电图。","authors":"Jayadev Nanda, Bhawesh Ch Saha, Amit Raj, Prabhakar Singh, Prerna Sinha","doi":"10.1007/s10792-024-03302-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the difference in ganglion cell layer (GCL) thickness on optical coherence tomography (OCT) and waveform on pattern electroretinography (PERG) among glaucoma suspects and healthy controls.</p><p><strong>Methods: </strong>An analytical, cross-sectional study was done on 100 eyes of 50 subjects, equally divided in the glaucoma suspect and control group. Subjects with an asymmetrically increased vertical cup-to-disc ratio and without any perimetric change were taken as suspects, and subjects with normal findings were taken as controls. GCL thickness was evaluated on spectral domain OCT at 3 mm, 3.45 mm, and 6 mm centering the foveola, and P50, N95 wave forms were recorded according to the standard PERG protocol.</p><p><strong>Results: </strong>In this study, we observed that the average GCL thickness is significantly less in glaucoma suspects at 3.45 mm (p = 0.045) and at 6 mm (p < 0.001) circle zone. On PERG, P50 amplitude was significantly low in glaucoma suspects in comparison to controls (p = 0.007). There was significantly increased implicit time for both P50 and N95 in glaucoma suspects (p < 0.001). For N95 amplitude, a non-significant (p = 0.127) difference was observed among the two groups. At 3.45 mm, average GCL thickness showed a weak negative correlation with N95 implicit time (r = - 0.286, p = 0.044), a weak positive correlation with P50 amplitude (r = 0.349, p = 0.013), and at 6 mm, a weak positive correlation with P50 amplitude (r = 0.311, p = 0.028) in glaucoma suspects.</p><p><strong>Conclusions: </strong>Analysing GCL thickness can help in the structural assessment of preperimetric glaucoma. PERG can be used as a valuable tool for the detection of ganglion cell dysfunction, even before cell loss.</p>","PeriodicalId":14473,"journal":{"name":"International Ophthalmology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of ganglion cell layer thickness and pattern electroretinography among glaucoma suspects and healthy controls.\",\"authors\":\"Jayadev Nanda, Bhawesh Ch Saha, Amit Raj, Prabhakar Singh, Prerna Sinha\",\"doi\":\"10.1007/s10792-024-03302-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the difference in ganglion cell layer (GCL) thickness on optical coherence tomography (OCT) and waveform on pattern electroretinography (PERG) among glaucoma suspects and healthy controls.</p><p><strong>Methods: </strong>An analytical, cross-sectional study was done on 100 eyes of 50 subjects, equally divided in the glaucoma suspect and control group. Subjects with an asymmetrically increased vertical cup-to-disc ratio and without any perimetric change were taken as suspects, and subjects with normal findings were taken as controls. GCL thickness was evaluated on spectral domain OCT at 3 mm, 3.45 mm, and 6 mm centering the foveola, and P50, N95 wave forms were recorded according to the standard PERG protocol.</p><p><strong>Results: </strong>In this study, we observed that the average GCL thickness is significantly less in glaucoma suspects at 3.45 mm (p = 0.045) and at 6 mm (p < 0.001) circle zone. On PERG, P50 amplitude was significantly low in glaucoma suspects in comparison to controls (p = 0.007). There was significantly increased implicit time for both P50 and N95 in glaucoma suspects (p < 0.001). For N95 amplitude, a non-significant (p = 0.127) difference was observed among the two groups. At 3.45 mm, average GCL thickness showed a weak negative correlation with N95 implicit time (r = - 0.286, p = 0.044), a weak positive correlation with P50 amplitude (r = 0.349, p = 0.013), and at 6 mm, a weak positive correlation with P50 amplitude (r = 0.311, p = 0.028) in glaucoma suspects.</p><p><strong>Conclusions: </strong>Analysing GCL thickness can help in the structural assessment of preperimetric glaucoma. PERG can be used as a valuable tool for the detection of ganglion cell dysfunction, even before cell loss.</p>\",\"PeriodicalId\":14473,\"journal\":{\"name\":\"International Ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-09-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10792-024-03302-7\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10792-024-03302-7","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估青光眼疑似患者和健康对照组的神经节细胞层(GCL)厚度在光学相干断层扫描(OCT)和模式视网膜电图(PERG)波形上的差异:对 50 名受试者的 100 只眼睛进行了横断面分析研究,青光眼疑似组和对照组各占一半。将垂直杯盘比不对称增加且无任何周边改变的受试者作为疑似青光眼患者,将检查结果正常的受试者作为对照组。以眼窝为中心,分别在 3 毫米、3.45 毫米和 6 毫米处用光谱域 OCT 评估 GCL 厚度,并按照标准 PERG 方案记录 P50、N95 波形:在这项研究中,我们观察到青光眼疑似患者的 GCL 平均厚度在 3.45 毫米(p = 0.045)和 6 毫米(p 结论:GCL 平均厚度在 3.45 毫米(p = 0.045)和 6 毫米(p = 0.045)时明显较低:分析 GCL 厚度有助于对先兆性青光眼的结构进行评估。PERG 可用作检测神经节细胞功能障碍的重要工具,甚至在细胞丧失之前。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of ganglion cell layer thickness and pattern electroretinography among glaucoma suspects and healthy controls.

Purpose: To evaluate the difference in ganglion cell layer (GCL) thickness on optical coherence tomography (OCT) and waveform on pattern electroretinography (PERG) among glaucoma suspects and healthy controls.

Methods: An analytical, cross-sectional study was done on 100 eyes of 50 subjects, equally divided in the glaucoma suspect and control group. Subjects with an asymmetrically increased vertical cup-to-disc ratio and without any perimetric change were taken as suspects, and subjects with normal findings were taken as controls. GCL thickness was evaluated on spectral domain OCT at 3 mm, 3.45 mm, and 6 mm centering the foveola, and P50, N95 wave forms were recorded according to the standard PERG protocol.

Results: In this study, we observed that the average GCL thickness is significantly less in glaucoma suspects at 3.45 mm (p = 0.045) and at 6 mm (p < 0.001) circle zone. On PERG, P50 amplitude was significantly low in glaucoma suspects in comparison to controls (p = 0.007). There was significantly increased implicit time for both P50 and N95 in glaucoma suspects (p < 0.001). For N95 amplitude, a non-significant (p = 0.127) difference was observed among the two groups. At 3.45 mm, average GCL thickness showed a weak negative correlation with N95 implicit time (r = - 0.286, p = 0.044), a weak positive correlation with P50 amplitude (r = 0.349, p = 0.013), and at 6 mm, a weak positive correlation with P50 amplitude (r = 0.311, p = 0.028) in glaucoma suspects.

Conclusions: Analysing GCL thickness can help in the structural assessment of preperimetric glaucoma. PERG can be used as a valuable tool for the detection of ganglion cell dysfunction, even before cell loss.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.20
自引率
0.00%
发文量
451
期刊介绍: International Ophthalmology provides the clinician with articles on all the relevant subspecialties of ophthalmology, with a broad international scope. The emphasis is on presentation of the latest clinical research in the field. In addition, the journal includes regular sections devoted to new developments in technologies, products, and techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信