Jang Won Son, Byoung-Duck Han, Jonathan P. Bennett, Steve Heymsfield, Soo Lim
{"title":"用于人体成分评估的生物电阻抗分析方法的开发和临床应用。","authors":"Jang Won Son, Byoung-Duck Han, Jonathan P. Bennett, Steve Heymsfield, Soo Lim","doi":"10.1111/obr.13844","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>Obesity, which is characterized by excessive body fat, increases the risk of chronic diseases, such as type 2 diabetes, cardiovascular diseases, and certain cancers. Sarcopenia, a decline in muscle mass, is also associated with many chronic disorders and is therefore a major concern in aging populations. Body composition analysis is important in the evaluation of obesity and sarcopenia because it provides information about the distribution of body fat and muscle mass. It is also useful for monitoring nutritional status, disease severity, and the effectiveness of interventions, such as exercise, diet, and drugs, and thus helps assess overall health and longevity. Computed tomography, magnetic resonance imaging, and dual-energy X-ray absorptiometry are commonly used for this purpose. However, they have limitations, such as high cost, long measurement time, and radiation exposure. Instead, bioelectrical impedance analysis (BIA), which was introduced several decades ago and has undergone significant technological advancements, can be used. It is easily accessible, affordable, and importantly, poses no radiation risk, making it suitable for use in hospitals, fitness centers, and even at home. Herein, we review the recent technological developments and clinical applications of BIA to provide an updated understanding of BIA technology and its strengths and limitations.</p>\n </div>","PeriodicalId":216,"journal":{"name":"Obesity Reviews","volume":"26 1","pages":""},"PeriodicalIF":8.0000,"publicationDate":"2024-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development and clinical application of bioelectrical impedance analysis method for body composition assessment\",\"authors\":\"Jang Won Son, Byoung-Duck Han, Jonathan P. Bennett, Steve Heymsfield, Soo Lim\",\"doi\":\"10.1111/obr.13844\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <p>Obesity, which is characterized by excessive body fat, increases the risk of chronic diseases, such as type 2 diabetes, cardiovascular diseases, and certain cancers. Sarcopenia, a decline in muscle mass, is also associated with many chronic disorders and is therefore a major concern in aging populations. Body composition analysis is important in the evaluation of obesity and sarcopenia because it provides information about the distribution of body fat and muscle mass. It is also useful for monitoring nutritional status, disease severity, and the effectiveness of interventions, such as exercise, diet, and drugs, and thus helps assess overall health and longevity. Computed tomography, magnetic resonance imaging, and dual-energy X-ray absorptiometry are commonly used for this purpose. However, they have limitations, such as high cost, long measurement time, and radiation exposure. Instead, bioelectrical impedance analysis (BIA), which was introduced several decades ago and has undergone significant technological advancements, can be used. It is easily accessible, affordable, and importantly, poses no radiation risk, making it suitable for use in hospitals, fitness centers, and even at home. Herein, we review the recent technological developments and clinical applications of BIA to provide an updated understanding of BIA technology and its strengths and limitations.</p>\\n </div>\",\"PeriodicalId\":216,\"journal\":{\"name\":\"Obesity Reviews\",\"volume\":\"26 1\",\"pages\":\"\"},\"PeriodicalIF\":8.0000,\"publicationDate\":\"2024-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Obesity Reviews\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/obr.13844\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Obesity Reviews","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/obr.13844","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0
摘要
肥胖症的特点是身体脂肪过多,会增加罹患慢性疾病的风险,如 2 型糖尿病、心血管疾病和某些癌症。肌肉减少症(肌肉质量下降)也与许多慢性疾病有关,因此是老龄人口的一个主要问题。身体成分分析对评估肥胖症和肌肉疏松症非常重要,因为它能提供有关身体脂肪和肌肉质量分布的信息。它还有助于监测营养状况、疾病严重程度以及运动、饮食和药物等干预措施的效果,从而帮助评估整体健康和寿命。计算机断层扫描、磁共振成像和双能 X 射线吸收测量法通常用于此目的。然而,这些方法存在成本高、测量时间长、辐射大等局限性。取而代之的是生物电阻抗分析法(BIA),该方法早在几十年前就已问世,并取得了重大技术进步。生物电阻抗分析法易于使用,价格低廉,更重要的是没有辐射风险,因此适合在医院、健身中心甚至家中使用。在此,我们回顾了 BIA 的最新技术发展和临床应用,以提供对 BIA 技术及其优势和局限性的最新了解。
Development and clinical application of bioelectrical impedance analysis method for body composition assessment
Obesity, which is characterized by excessive body fat, increases the risk of chronic diseases, such as type 2 diabetes, cardiovascular diseases, and certain cancers. Sarcopenia, a decline in muscle mass, is also associated with many chronic disorders and is therefore a major concern in aging populations. Body composition analysis is important in the evaluation of obesity and sarcopenia because it provides information about the distribution of body fat and muscle mass. It is also useful for monitoring nutritional status, disease severity, and the effectiveness of interventions, such as exercise, diet, and drugs, and thus helps assess overall health and longevity. Computed tomography, magnetic resonance imaging, and dual-energy X-ray absorptiometry are commonly used for this purpose. However, they have limitations, such as high cost, long measurement time, and radiation exposure. Instead, bioelectrical impedance analysis (BIA), which was introduced several decades ago and has undergone significant technological advancements, can be used. It is easily accessible, affordable, and importantly, poses no radiation risk, making it suitable for use in hospitals, fitness centers, and even at home. Herein, we review the recent technological developments and clinical applications of BIA to provide an updated understanding of BIA technology and its strengths and limitations.
期刊介绍:
Obesity Reviews is a monthly journal publishing reviews on all disciplines related to obesity and its comorbidities. This includes basic and behavioral sciences, clinical treatment and outcomes, epidemiology, prevention and public health. The journal should, therefore, appeal to all professionals with an interest in obesity and its comorbidities.
Review types may include systematic narrative reviews, quantitative meta-analyses and narrative reviews but all must offer new insights, critical or novel perspectives that will enhance the state of knowledge in the field.
The editorial policy is to publish high quality peer-reviewed manuscripts that provide needed new insight into all aspects of obesity and its related comorbidities while minimizing the period between submission and publication.