使用新型髓外内牵引器进行牵引成骨的有限元分析。

IF 1.7 4区 医学 Q3 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS
Mohammad Ali Bagheri, Carl-Eric Aubin, Marie-Lyne Nault, Isabelle Villemure
{"title":"使用新型髓外内牵引器进行牵引成骨的有限元分析。","authors":"Mohammad Ali Bagheri, Carl-Eric Aubin, Marie-Lyne Nault, Isabelle Villemure","doi":"10.1080/10255842.2024.2406367","DOIUrl":null,"url":null,"abstract":"<p><p>Distraction osteogenesis (DO) is a bone regenerative maneuver, which is conventionally done with external fixators and, more recently, with telescopic intramedullary nails. Despite the proven effectiveness, external approaches are intrusive to the patient's life while intramedullary nailing damages the growth plates, making them unsuitable for pediatric patients. An internal DO plate fixator (IDOPF) was developed for pediatric patients to address these limitations. The objective of this study was to test the hypothesis that the IDOPF can withstand a partial weight bearing scenario and create a favorable mechanical microenvironment at the osteotomy gap for bone regeneration as the device elongates. A finite element model of a surrogated long bone diaphysis osteotomy fixation by means of the IDOPF was created and subjected to axial compression, bending and torsion. As the osteotomy gap increased from 2 mm to 20 mm, under compression, The average axial interfragmentary strains decreased from 2.33% to 0.35%. Stress increased from 179 MPa to 281 MPa at the contact interfaces of the telescopic compartments, which exceeded the endurance limit of stainless steel (270 MPa) but was below its yield limit (415 MPa). These results demonstrate, that the IDOPF can withstand a partial load bearing scenario and provide a stable biomechanical environment conductive to bone healing. However, high contact stresses at the telescopic interfaces of the device are likely to cause wear, as is frequently reported in telescopic fixators. This study is a step towards refining the IDOPF design for clinical use.</p>","PeriodicalId":50640,"journal":{"name":"Computer Methods in Biomechanics and Biomedical Engineering","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Finite element analysis of distraction osteogenesis with a new extramedullary internal distractor.\",\"authors\":\"Mohammad Ali Bagheri, Carl-Eric Aubin, Marie-Lyne Nault, Isabelle Villemure\",\"doi\":\"10.1080/10255842.2024.2406367\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Distraction osteogenesis (DO) is a bone regenerative maneuver, which is conventionally done with external fixators and, more recently, with telescopic intramedullary nails. Despite the proven effectiveness, external approaches are intrusive to the patient's life while intramedullary nailing damages the growth plates, making them unsuitable for pediatric patients. An internal DO plate fixator (IDOPF) was developed for pediatric patients to address these limitations. The objective of this study was to test the hypothesis that the IDOPF can withstand a partial weight bearing scenario and create a favorable mechanical microenvironment at the osteotomy gap for bone regeneration as the device elongates. A finite element model of a surrogated long bone diaphysis osteotomy fixation by means of the IDOPF was created and subjected to axial compression, bending and torsion. As the osteotomy gap increased from 2 mm to 20 mm, under compression, The average axial interfragmentary strains decreased from 2.33% to 0.35%. Stress increased from 179 MPa to 281 MPa at the contact interfaces of the telescopic compartments, which exceeded the endurance limit of stainless steel (270 MPa) but was below its yield limit (415 MPa). These results demonstrate, that the IDOPF can withstand a partial load bearing scenario and provide a stable biomechanical environment conductive to bone healing. However, high contact stresses at the telescopic interfaces of the device are likely to cause wear, as is frequently reported in telescopic fixators. This study is a step towards refining the IDOPF design for clinical use.</p>\",\"PeriodicalId\":50640,\"journal\":{\"name\":\"Computer Methods in Biomechanics and Biomedical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computer Methods in Biomechanics and Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/10255842.2024.2406367\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Methods in Biomechanics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/10255842.2024.2406367","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

摘要

牵引成骨术(DO)是一种骨再生方法,传统上使用外固定器,最近则使用伸缩式髓内钉。尽管外固定器的有效性已得到证实,但它会对患者的生活造成干扰,而髓内钉会损伤生长板,因此不适合儿童患者。为了解决这些局限性,我们为儿童患者开发了DO钢板内固定器(IDOPF)。本研究的目的是测试一种假设,即 IDOPF 可以承受部分负重情况,并随着装置的伸长在截骨间隙处为骨再生创造有利的机械微环境。通过 IDOPF 建立了一个替代长骨骨骺截骨固定的有限元模型,并对其进行轴向压缩、弯曲和扭转。在压缩条件下,随着截骨间隙从 2 毫米增加到 20 毫米,平均轴向节间应变从 2.33% 降至 0.35%。伸缩隔间接触界面的应力从 179 兆帕增加到 281 兆帕,超过了不锈钢的耐力极限(270 兆帕),但低于其屈服极限(415 兆帕)。这些结果表明,IDOPF 可以承受部分负荷,并提供有利于骨愈合的稳定生物力学环境。然而,该装置伸缩界面的高接触应力很可能会导致磨损,这在伸缩式固定器中屡见报端。这项研究为改进 IDOPF 的设计以应用于临床迈出了一步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Finite element analysis of distraction osteogenesis with a new extramedullary internal distractor.

Distraction osteogenesis (DO) is a bone regenerative maneuver, which is conventionally done with external fixators and, more recently, with telescopic intramedullary nails. Despite the proven effectiveness, external approaches are intrusive to the patient's life while intramedullary nailing damages the growth plates, making them unsuitable for pediatric patients. An internal DO plate fixator (IDOPF) was developed for pediatric patients to address these limitations. The objective of this study was to test the hypothesis that the IDOPF can withstand a partial weight bearing scenario and create a favorable mechanical microenvironment at the osteotomy gap for bone regeneration as the device elongates. A finite element model of a surrogated long bone diaphysis osteotomy fixation by means of the IDOPF was created and subjected to axial compression, bending and torsion. As the osteotomy gap increased from 2 mm to 20 mm, under compression, The average axial interfragmentary strains decreased from 2.33% to 0.35%. Stress increased from 179 MPa to 281 MPa at the contact interfaces of the telescopic compartments, which exceeded the endurance limit of stainless steel (270 MPa) but was below its yield limit (415 MPa). These results demonstrate, that the IDOPF can withstand a partial load bearing scenario and provide a stable biomechanical environment conductive to bone healing. However, high contact stresses at the telescopic interfaces of the device are likely to cause wear, as is frequently reported in telescopic fixators. This study is a step towards refining the IDOPF design for clinical use.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
6.20%
发文量
179
审稿时长
4-8 weeks
期刊介绍: The primary aims of Computer Methods in Biomechanics and Biomedical Engineering are to provide a means of communicating the advances being made in the areas of biomechanics and biomedical engineering and to stimulate interest in the continually emerging computer based technologies which are being applied in these multidisciplinary subjects. Computer Methods in Biomechanics and Biomedical Engineering will also provide a focus for the importance of integrating the disciplines of engineering with medical technology and clinical expertise. Such integration will have a major impact on health care in the future.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信