牙髓腔前臼齿牙髓敷料中钙离子和羟基离子释放量的对比分析

IF 3.1 4区 医学 Q1 Medicine
Wafa H Alaajam, Khalid M Abdelaziz, Ashraf Abdelfattah Khalil, Hoda Lotfy Abouzeid, Ghadeer Saleh Alwadai, Arwa Ali Y Daghrery, Munirah Ahmed Almuawwad, Abeer Saeed Alqahtani, Tasneem A Humhum, Mohammed M Al Moaleem
{"title":"牙髓腔前臼齿牙髓敷料中钙离子和羟基离子释放量的对比分析","authors":"Wafa H Alaajam, Khalid M Abdelaziz, Ashraf Abdelfattah Khalil, Hoda Lotfy Abouzeid, Ghadeer Saleh Alwadai, Arwa Ali Y Daghrery, Munirah Ahmed Almuawwad, Abeer Saeed Alqahtani, Tasneem A Humhum, Mohammed M Al Moaleem","doi":"10.12659/MSM.945089","DOIUrl":null,"url":null,"abstract":"<p><p>BACKGROUND The aim of this study was to evaluate the time-dependent release of calcium (Ca⁺⁺) and hydroxyl (OH⁻) ions from 3 different pulp dressing materials used to cap root canal orifices in pulpotomized premolars. MATERIAL AND METHODS Freshly extracted (n=40) premolars were subjected to standardized pulpotomy procedure and finally restored in 5 groups using resin-modified glass ionmmer liner (RMGI) and bonded resin composite directly against the pulp chamber's floor (Control, G2) and over 3 different orifices' capping materials - Dycal (G3), Endo Sequence root repair material (ESRRM, G4), and mineral trioxide aggregate (MTA) Angelus (G5). Another 10 sound premolars served as the Reference group (G1). The restored teeth were incubated at 37±1°C in sealed containers filled with deionized water to assess Ca⁺⁺ and OH⁻ ions release after 24 h and at 1, 4, and 8 weeks. Two-way ANOVA and Tukey's comparisons at alpha=0.05 were used to statistically analyze the collected data. RESULTS Two-way ANOVA revealed significant differences in Ca⁺⁺ ions between test groups at different testing time intervals (P<0.05). Despite the constant (Tukey's, P<0.05) pH levels (OH⁻ release), Group 5 specimens exhibited higher Ca⁺⁺ ion release in comparison to Groups 4 and 3 at different testing timepoints (Tukey's, P<0.05). CONCLUSIONS Although all the assessed pulp dressing materials had equivalent and stable pH levels, ESRRM and MTA-Angelus had the highest Ca⁺⁺ ion release at the assessment intervals.</p>","PeriodicalId":48888,"journal":{"name":"Medical Science Monitor","volume":"30 ","pages":"e945089"},"PeriodicalIF":3.1000,"publicationDate":"2024-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11446174/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparative Analysis of Calcium and Hydroxyl Ion Release from Pulp Dressing Materials in Pulpotomized Premolars.\",\"authors\":\"Wafa H Alaajam, Khalid M Abdelaziz, Ashraf Abdelfattah Khalil, Hoda Lotfy Abouzeid, Ghadeer Saleh Alwadai, Arwa Ali Y Daghrery, Munirah Ahmed Almuawwad, Abeer Saeed Alqahtani, Tasneem A Humhum, Mohammed M Al Moaleem\",\"doi\":\"10.12659/MSM.945089\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>BACKGROUND The aim of this study was to evaluate the time-dependent release of calcium (Ca⁺⁺) and hydroxyl (OH⁻) ions from 3 different pulp dressing materials used to cap root canal orifices in pulpotomized premolars. MATERIAL AND METHODS Freshly extracted (n=40) premolars were subjected to standardized pulpotomy procedure and finally restored in 5 groups using resin-modified glass ionmmer liner (RMGI) and bonded resin composite directly against the pulp chamber's floor (Control, G2) and over 3 different orifices' capping materials - Dycal (G3), Endo Sequence root repair material (ESRRM, G4), and mineral trioxide aggregate (MTA) Angelus (G5). Another 10 sound premolars served as the Reference group (G1). The restored teeth were incubated at 37±1°C in sealed containers filled with deionized water to assess Ca⁺⁺ and OH⁻ ions release after 24 h and at 1, 4, and 8 weeks. Two-way ANOVA and Tukey's comparisons at alpha=0.05 were used to statistically analyze the collected data. RESULTS Two-way ANOVA revealed significant differences in Ca⁺⁺ ions between test groups at different testing time intervals (P<0.05). Despite the constant (Tukey's, P<0.05) pH levels (OH⁻ release), Group 5 specimens exhibited higher Ca⁺⁺ ion release in comparison to Groups 4 and 3 at different testing timepoints (Tukey's, P<0.05). CONCLUSIONS Although all the assessed pulp dressing materials had equivalent and stable pH levels, ESRRM and MTA-Angelus had the highest Ca⁺⁺ ion release at the assessment intervals.</p>\",\"PeriodicalId\":48888,\"journal\":{\"name\":\"Medical Science Monitor\",\"volume\":\"30 \",\"pages\":\"e945089\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11446174/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Science Monitor\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.12659/MSM.945089\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Science Monitor","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.12659/MSM.945089","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

背景 本研究旨在评估用于封闭牙髓切断术后前磨牙根管口的 3 种不同牙髓敷料中钙离子(Ca⁺⁺)和羟基离子(OH-)的释放随时间变化的情况。材料和方法 新鲜拔出的前臼齿(n=40)经过标准化的牙髓切断术,最后分成 5 组,分别使用树脂改性玻璃离子聚合物衬垫(RMGI)和粘结树脂复合材料直接贴在髓腔底部(对照组,G2),以及 3 种不同的根管口封顶材料--Dycal(G3)、Endo Sequence 根修复材料(ESRRM,G4)和三氧化矿骨料(MTA)Angelus(G5)进行修复。另外 10 颗完好的前臼齿作为参照组(G1)。修复后的牙齿在装有去离子水的密封容器中于 37±1°C 的温度下培养,以评估 24 小时后以及 1、4 和 8 周时 Ca⁺⁺ 和 OH- 离子的释放情况。采用双向方差分析和 Tukey(α=0.05)比较对收集的数据进行统计分析。结果 双向方差分析显示,在不同测试时间间隔内,测试组之间的 Ca⁺⁺离子含量存在显著差异(P<0.05)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative Analysis of Calcium and Hydroxyl Ion Release from Pulp Dressing Materials in Pulpotomized Premolars.

BACKGROUND The aim of this study was to evaluate the time-dependent release of calcium (Ca⁺⁺) and hydroxyl (OH⁻) ions from 3 different pulp dressing materials used to cap root canal orifices in pulpotomized premolars. MATERIAL AND METHODS Freshly extracted (n=40) premolars were subjected to standardized pulpotomy procedure and finally restored in 5 groups using resin-modified glass ionmmer liner (RMGI) and bonded resin composite directly against the pulp chamber's floor (Control, G2) and over 3 different orifices' capping materials - Dycal (G3), Endo Sequence root repair material (ESRRM, G4), and mineral trioxide aggregate (MTA) Angelus (G5). Another 10 sound premolars served as the Reference group (G1). The restored teeth were incubated at 37±1°C in sealed containers filled with deionized water to assess Ca⁺⁺ and OH⁻ ions release after 24 h and at 1, 4, and 8 weeks. Two-way ANOVA and Tukey's comparisons at alpha=0.05 were used to statistically analyze the collected data. RESULTS Two-way ANOVA revealed significant differences in Ca⁺⁺ ions between test groups at different testing time intervals (P<0.05). Despite the constant (Tukey's, P<0.05) pH levels (OH⁻ release), Group 5 specimens exhibited higher Ca⁺⁺ ion release in comparison to Groups 4 and 3 at different testing timepoints (Tukey's, P<0.05). CONCLUSIONS Although all the assessed pulp dressing materials had equivalent and stable pH levels, ESRRM and MTA-Angelus had the highest Ca⁺⁺ ion release at the assessment intervals.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Medical Science Monitor
Medical Science Monitor MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
6.40
自引率
3.20%
发文量
514
审稿时长
3.0 months
期刊介绍: Medical Science Monitor (MSM) established in 1995 is an international, peer-reviewed scientific journal which publishes original articles in Clinical Medicine and related disciplines such as Epidemiology and Population Studies, Product Investigations, Development of Laboratory Techniques :: Diagnostics and Medical Technology which enable presentation of research or review works in overlapping areas of medicine and technology such us (but not limited to): medical diagnostics, medical imaging systems, computer simulation of health and disease processes, new medical devices, etc. Reviews and Special Reports - papers may be accepted on the basis that they provide a systematic, critical and up-to-date overview of literature pertaining to research or clinical topics. Meta-analyses are considered as reviews. A special attention will be paid to a teaching value of a review paper. Medical Science Monitor is internationally indexed in Thomson-Reuters Web of Science, Journals Citation Report (JCR), Science Citation Index Expanded (SCI), Index Medicus MEDLINE, PubMed, PMC, EMBASE/Excerpta Medica, Chemical Abstracts CAS and Index Copernicus.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信