Zhenyu Yang , Ziyi Liu , Jie Zhang , Xiaoxiao Li , Daxiong Zeng , Chuanyong Mu , Junhong Jiang
{"title":"关于在兔气管中植入不同类型金属支架后并发症的研究","authors":"Zhenyu Yang , Ziyi Liu , Jie Zhang , Xiaoxiao Li , Daxiong Zeng , Chuanyong Mu , Junhong Jiang","doi":"10.1016/j.ijporl.2024.112111","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To observe the complications and inflammatory responses caused by the different types of metal stents in the trachea of rabbits.</div></div><div><h3>Method</h3><div>79 rabbits were randomly divided into 4 groups and were implanted with the customized nickel-titanium alloy metal stents(fully covered metal stent: group A, bare metal stent: group B, segmented covered metal stent: group C and control group: group D). The complications (tracheal deformation, granulation tissue hyperplasia, scar hyperplasia and secretion retention) of different types of metal stents were compared by observing the anatomical and pathological specimens of dead rabbits; And the expression of inflammatory factors of different types of metal stents were compared by detecting the tissue of tracheas of dead rabbits.</div></div><div><h3>Results</h3><div>(1)There were significant differences in the above four complications among groups A, B and C(<em>p</em> < 0.01). The incidences of tracheal deformation, scar hyperplasia and secretion retention in group A were significantly higher than that in group B(<em>p</em> < 0.0167), however, the incidence of granulation tissue hyperplasia in group A was significantly lower than that in group B(<em>p</em> < 0.0167). The incidence of scar hyperplasia in group A was significantly lower than that in group C(<em>p</em> < 0.0167) and there were no significant differences in other complications between these two groups(<em>p</em> > 0.0167). The incidences of tracheal deformation, scar hyperplasia and secretion retention in group B were significantly lower than that in group C(<em>p</em> < 0.0167), however, the incidence of granulation tissue hyperplasia in group B was significantly higher than that in group C(<em>p</em> < 0.0167). (2)The concentration of IL-1β in group A was higher than that in group B (<em>p</em> < 0.05 and foldchange>1.2).</div></div><div><h3>Conclusion</h3><div>(1)There are significant differences in complications between the fully covered metal stent, bare metal stent and segmented covered metal stent; the incidences of complications between the segmented covered metal stent and fully covered metal stent are similar. (2)Changes in different inflammatory factors can be observed between the fully covered and bare metal stent.</div></div>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study on the complications after implantation of different types of metal stents in rabbit trachea\",\"authors\":\"Zhenyu Yang , Ziyi Liu , Jie Zhang , Xiaoxiao Li , Daxiong Zeng , Chuanyong Mu , Junhong Jiang\",\"doi\":\"10.1016/j.ijporl.2024.112111\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><div>To observe the complications and inflammatory responses caused by the different types of metal stents in the trachea of rabbits.</div></div><div><h3>Method</h3><div>79 rabbits were randomly divided into 4 groups and were implanted with the customized nickel-titanium alloy metal stents(fully covered metal stent: group A, bare metal stent: group B, segmented covered metal stent: group C and control group: group D). The complications (tracheal deformation, granulation tissue hyperplasia, scar hyperplasia and secretion retention) of different types of metal stents were compared by observing the anatomical and pathological specimens of dead rabbits; And the expression of inflammatory factors of different types of metal stents were compared by detecting the tissue of tracheas of dead rabbits.</div></div><div><h3>Results</h3><div>(1)There were significant differences in the above four complications among groups A, B and C(<em>p</em> < 0.01). The incidences of tracheal deformation, scar hyperplasia and secretion retention in group A were significantly higher than that in group B(<em>p</em> < 0.0167), however, the incidence of granulation tissue hyperplasia in group A was significantly lower than that in group B(<em>p</em> < 0.0167). The incidence of scar hyperplasia in group A was significantly lower than that in group C(<em>p</em> < 0.0167) and there were no significant differences in other complications between these two groups(<em>p</em> > 0.0167). The incidences of tracheal deformation, scar hyperplasia and secretion retention in group B were significantly lower than that in group C(<em>p</em> < 0.0167), however, the incidence of granulation tissue hyperplasia in group B was significantly higher than that in group C(<em>p</em> < 0.0167). (2)The concentration of IL-1β in group A was higher than that in group B (<em>p</em> < 0.05 and foldchange>1.2).</div></div><div><h3>Conclusion</h3><div>(1)There are significant differences in complications between the fully covered metal stent, bare metal stent and segmented covered metal stent; the incidences of complications between the segmented covered metal stent and fully covered metal stent are similar. (2)Changes in different inflammatory factors can be observed between the fully covered and bare metal stent.</div></div>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0165587624002659\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0165587624002659","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Study on the complications after implantation of different types of metal stents in rabbit trachea
Objective
To observe the complications and inflammatory responses caused by the different types of metal stents in the trachea of rabbits.
Method
79 rabbits were randomly divided into 4 groups and were implanted with the customized nickel-titanium alloy metal stents(fully covered metal stent: group A, bare metal stent: group B, segmented covered metal stent: group C and control group: group D). The complications (tracheal deformation, granulation tissue hyperplasia, scar hyperplasia and secretion retention) of different types of metal stents were compared by observing the anatomical and pathological specimens of dead rabbits; And the expression of inflammatory factors of different types of metal stents were compared by detecting the tissue of tracheas of dead rabbits.
Results
(1)There were significant differences in the above four complications among groups A, B and C(p < 0.01). The incidences of tracheal deformation, scar hyperplasia and secretion retention in group A were significantly higher than that in group B(p < 0.0167), however, the incidence of granulation tissue hyperplasia in group A was significantly lower than that in group B(p < 0.0167). The incidence of scar hyperplasia in group A was significantly lower than that in group C(p < 0.0167) and there were no significant differences in other complications between these two groups(p > 0.0167). The incidences of tracheal deformation, scar hyperplasia and secretion retention in group B were significantly lower than that in group C(p < 0.0167), however, the incidence of granulation tissue hyperplasia in group B was significantly higher than that in group C(p < 0.0167). (2)The concentration of IL-1β in group A was higher than that in group B (p < 0.05 and foldchange>1.2).
Conclusion
(1)There are significant differences in complications between the fully covered metal stent, bare metal stent and segmented covered metal stent; the incidences of complications between the segmented covered metal stent and fully covered metal stent are similar. (2)Changes in different inflammatory factors can be observed between the fully covered and bare metal stent.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.