全膝关节置换术中多层伤口闭合的三种表皮闭合方法的安全性和有效性比较:一项多中心、前瞻性、随机对照试验。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
Te Liu, Ye Tao, Runkai Zhao, Yanfan Hua, Zeyu Feng, Qingyuan Zheng, Guoqiang Zhang, Lei Geng, Jun Fu, Wenwei Qian, Ming Ni, Weijun Wang
{"title":"全膝关节置换术中多层伤口闭合的三种表皮闭合方法的安全性和有效性比较:一项多中心、前瞻性、随机对照试验。","authors":"Te Liu, Ye Tao, Runkai Zhao, Yanfan Hua, Zeyu Feng, Qingyuan Zheng, Guoqiang Zhang, Lei Geng, Jun Fu, Wenwei Qian, Ming Ni, Weijun Wang","doi":"10.1186/s42836-024-00271-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Good wound healing is critical to infection prophylaxis and satisfactory rehabilitation in Total Knee Arthroplasty (TKA). Currently, two techniques, i.e., barbed continuous subcuticular suture without skin adhesive or combined use skin adhesive (n-butyl-2) are being used for superficial wound closure of TKA. While a new skin adhesive (2-octyl) with self-adhesive mesh has been employed as an alternative to conventional surgical skin closure in TKA, its superiority, especially in reducing wound complications and improving wound cosmetic outcomes has not been investigated. This study aimed to compare 2-octyl, n-butyl-2, and no skin adhesive in terms of safety and efficacy in TKA superficial wound closure.</p><p><strong>Methods: </strong>We conducted a multicenter, prospective, randomized controlled study in 105 patients undergoing primary TKA between May 2022 and October 2023. Each patient's knee was randomized to receive 2-octyl, n-butyl-2, or no skin adhesive skin closure with all using barbed continuous sutures in deep tissue. Wounds were followed 1, 3, 5 days, 2, 6 weeks, and 3 months after surgery. Wound discharge, complications, cosmetic outcomes, patient satisfaction, and wound-related costs were compared among these three methods.</p><p><strong>Results: </strong>Wound discharge was less in 2-octyl group and n-butyl-2 group than in non-adhesive group at 1 day, with the discharge only being less in 2-octyl group than in the non-adhesive group at day 3 and day 5 days (P < 0.05). There was no statistical difference in the incidence of other wound complications among the groups (P > 0.05). The 2-octyl group achieved better cosmetic effects than the other two groups in 6 weeks and 3 months (P < 0.05). Compared to the non-adhesive group, 2-octyl group scored higher in overall patient satisfaction score in 2 weeks and incurred lower costs (P < 0.05).</p><p><strong>Conclusions: </strong>Skin closure in TKA using 2-octyl adhesive material showed superiority when compared to no skin adhesive or n-butyl-2, in reducing wound discharge, improving the cosmetic outcomes, without increasing wound complications. In addition, the use of 2-octyl yielded better patient satisfaction and also was less costly compared to no skin adhesive. Our study exhibited that 2-octyl was a safe and effective wound closure technique for patients undergoing TKA.</p><p><strong>Trial registration: </strong>This study has been registered at Clinical Trials. Gov (No. ChiCTR210046442).</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11389524/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of the safety and efficacy of three superficial skin closure methods for multi-layer wound closure in total knee arthroplasty: a multicenter, prospective, randomized controlled trial.\",\"authors\":\"Te Liu, Ye Tao, Runkai Zhao, Yanfan Hua, Zeyu Feng, Qingyuan Zheng, Guoqiang Zhang, Lei Geng, Jun Fu, Wenwei Qian, Ming Ni, Weijun Wang\",\"doi\":\"10.1186/s42836-024-00271-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Good wound healing is critical to infection prophylaxis and satisfactory rehabilitation in Total Knee Arthroplasty (TKA). Currently, two techniques, i.e., barbed continuous subcuticular suture without skin adhesive or combined use skin adhesive (n-butyl-2) are being used for superficial wound closure of TKA. While a new skin adhesive (2-octyl) with self-adhesive mesh has been employed as an alternative to conventional surgical skin closure in TKA, its superiority, especially in reducing wound complications and improving wound cosmetic outcomes has not been investigated. This study aimed to compare 2-octyl, n-butyl-2, and no skin adhesive in terms of safety and efficacy in TKA superficial wound closure.</p><p><strong>Methods: </strong>We conducted a multicenter, prospective, randomized controlled study in 105 patients undergoing primary TKA between May 2022 and October 2023. Each patient's knee was randomized to receive 2-octyl, n-butyl-2, or no skin adhesive skin closure with all using barbed continuous sutures in deep tissue. Wounds were followed 1, 3, 5 days, 2, 6 weeks, and 3 months after surgery. Wound discharge, complications, cosmetic outcomes, patient satisfaction, and wound-related costs were compared among these three methods.</p><p><strong>Results: </strong>Wound discharge was less in 2-octyl group and n-butyl-2 group than in non-adhesive group at 1 day, with the discharge only being less in 2-octyl group than in the non-adhesive group at day 3 and day 5 days (P < 0.05). There was no statistical difference in the incidence of other wound complications among the groups (P > 0.05). The 2-octyl group achieved better cosmetic effects than the other two groups in 6 weeks and 3 months (P < 0.05). Compared to the non-adhesive group, 2-octyl group scored higher in overall patient satisfaction score in 2 weeks and incurred lower costs (P < 0.05).</p><p><strong>Conclusions: </strong>Skin closure in TKA using 2-octyl adhesive material showed superiority when compared to no skin adhesive or n-butyl-2, in reducing wound discharge, improving the cosmetic outcomes, without increasing wound complications. In addition, the use of 2-octyl yielded better patient satisfaction and also was less costly compared to no skin adhesive. Our study exhibited that 2-octyl was a safe and effective wound closure technique for patients undergoing TKA.</p><p><strong>Trial registration: </strong>This study has been registered at Clinical Trials. Gov (No. ChiCTR210046442).</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11389524/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s42836-024-00271-1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s42836-024-00271-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

背景:良好的伤口愈合对于全膝关节置换术(TKA)的预防感染和满意康复至关重要。目前,有两种技术被用于 TKA 表皮伤口的缝合,即不使用皮肤粘合剂的带刺连续皮下缝合或联合使用皮肤粘合剂(正丁基-2)。虽然一种新型皮肤粘合剂(2-辛基)与自粘网已被用于替代传统的 TKA 皮肤闭合术,但其优越性,尤其是在减少伤口并发症和改善伤口美容效果方面的优越性尚未得到研究。本研究旨在比较 2-辛基、2-正丁基和无皮肤粘合剂在 TKA 表皮伤口闭合中的安全性和有效性:我们在 2022 年 5 月至 2023 年 10 月期间对 105 名接受初次 TKA 的患者进行了一项多中心、前瞻性、随机对照研究。每名患者的膝关节被随机分为接受 2-辛基、2-正丁基或无皮肤粘合剂皮肤闭合,所有患者均在深层组织中使用带倒刺的连续缝合线。术后 1 天、3 天、5 天、2 周、6 周和 3 个月分别对伤口进行随访。对这三种方法的伤口排出量、并发症、美容效果、患者满意度和伤口相关费用进行了比较:1天时,2-辛基组和 n-butyl-2 组的伤口分泌物少于无粘合剂组,第 3 天和第 5 天时,2-辛基组的伤口分泌物仅少于无粘合剂组(P 0.05)。在 6 周和 3 个月后,2-辛基组比其他两组获得了更好的美容效果(P 结论:2-辛基组在 6 周和 3 个月后获得了更好的美容效果:与不使用皮肤粘合剂或正丁基-2 相比,在 TKA 中使用 2-辛基粘合材料进行皮肤闭合在减少伤口分泌物、改善美容效果和不增加伤口并发症方面表现出了优势。此外,与不使用皮肤粘合剂相比,使用 2-辛基粘合剂能获得更好的患者满意度,成本也更低。我们的研究表明,2-辛基对接受 TKA 手术的患者来说是一种安全有效的伤口闭合技术:本研究已在 Clinical Trials.Gov(编号:ChiCTR210046442)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of the safety and efficacy of three superficial skin closure methods for multi-layer wound closure in total knee arthroplasty: a multicenter, prospective, randomized controlled trial.

Background: Good wound healing is critical to infection prophylaxis and satisfactory rehabilitation in Total Knee Arthroplasty (TKA). Currently, two techniques, i.e., barbed continuous subcuticular suture without skin adhesive or combined use skin adhesive (n-butyl-2) are being used for superficial wound closure of TKA. While a new skin adhesive (2-octyl) with self-adhesive mesh has been employed as an alternative to conventional surgical skin closure in TKA, its superiority, especially in reducing wound complications and improving wound cosmetic outcomes has not been investigated. This study aimed to compare 2-octyl, n-butyl-2, and no skin adhesive in terms of safety and efficacy in TKA superficial wound closure.

Methods: We conducted a multicenter, prospective, randomized controlled study in 105 patients undergoing primary TKA between May 2022 and October 2023. Each patient's knee was randomized to receive 2-octyl, n-butyl-2, or no skin adhesive skin closure with all using barbed continuous sutures in deep tissue. Wounds were followed 1, 3, 5 days, 2, 6 weeks, and 3 months after surgery. Wound discharge, complications, cosmetic outcomes, patient satisfaction, and wound-related costs were compared among these three methods.

Results: Wound discharge was less in 2-octyl group and n-butyl-2 group than in non-adhesive group at 1 day, with the discharge only being less in 2-octyl group than in the non-adhesive group at day 3 and day 5 days (P < 0.05). There was no statistical difference in the incidence of other wound complications among the groups (P > 0.05). The 2-octyl group achieved better cosmetic effects than the other two groups in 6 weeks and 3 months (P < 0.05). Compared to the non-adhesive group, 2-octyl group scored higher in overall patient satisfaction score in 2 weeks and incurred lower costs (P < 0.05).

Conclusions: Skin closure in TKA using 2-octyl adhesive material showed superiority when compared to no skin adhesive or n-butyl-2, in reducing wound discharge, improving the cosmetic outcomes, without increasing wound complications. In addition, the use of 2-octyl yielded better patient satisfaction and also was less costly compared to no skin adhesive. Our study exhibited that 2-octyl was a safe and effective wound closure technique for patients undergoing TKA.

Trial registration: This study has been registered at Clinical Trials. Gov (No. ChiCTR210046442).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信