{"title":"男性吊带:替代人工尿道括约肌治疗男性压力性尿失禁的有效而安全的手术疗法?","authors":"Eric Chung, Brian Ng Hung Shin, Juan Wang","doi":"10.21037/tau-23-13","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objective: </strong>The ideal candidate for a male sling (MS) should have a mild to moderate degree of stress urinary incontinence (SUI). This narrative review article evaluates the current MS devices in the commercial market and examines the role of MS as an effective and safe alternative treatment option for male SUI.</p><p><strong>Methods: </strong>The available literature on MS was reviewed and relevant clinical studies pertaining to each MS were summarised with emphasis on device design and technology as well as specific surgical findings relating to clinical outcomes.</p><p><strong>Key content and findings: </strong>Over the past two decades, there have been considerable scientific advances in MS design and technology, and MS is an attractive alternative for patients who might not require or want an artificial urinary sphincter. The modern MS can be classified as adjustable or non-adjustable types and is placed either through a retropubic or transobturator (TO) approach. Strict patient selection and counselling, selection of MS with proven clinical records, and safe surgical practice are paramount to ensure a high continence rate, good patient satisfaction, and low postoperative complications. Published data on various MS materials and devices showed reasonable clinical efficacy and safety outcomes, although many of these synthetic MS devices may not be available worldwide due to a lack of regulatory approval in many countries. While the ideal MS is probably yet to be developed, continued scientific advances in slings design, mesh technology, and more refined surgical techniques will improve the continence rate and deliver better safety records.</p><p><strong>Conclusions: </strong>As clinical data matures with longer-term outcomes coupled with advances in scientific designs and technology, the ability to have and select the optimal MS for a particular patient will come to fruition.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11399030/pdf/","citationCount":"0","resultStr":"{\"title\":\"The male slings: an effective and safe alternative surgical treatment to the artificial urinary sphincter for male stress urinary incontinence?-a narrative review.\",\"authors\":\"Eric Chung, Brian Ng Hung Shin, Juan Wang\",\"doi\":\"10.21037/tau-23-13\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and objective: </strong>The ideal candidate for a male sling (MS) should have a mild to moderate degree of stress urinary incontinence (SUI). This narrative review article evaluates the current MS devices in the commercial market and examines the role of MS as an effective and safe alternative treatment option for male SUI.</p><p><strong>Methods: </strong>The available literature on MS was reviewed and relevant clinical studies pertaining to each MS were summarised with emphasis on device design and technology as well as specific surgical findings relating to clinical outcomes.</p><p><strong>Key content and findings: </strong>Over the past two decades, there have been considerable scientific advances in MS design and technology, and MS is an attractive alternative for patients who might not require or want an artificial urinary sphincter. The modern MS can be classified as adjustable or non-adjustable types and is placed either through a retropubic or transobturator (TO) approach. Strict patient selection and counselling, selection of MS with proven clinical records, and safe surgical practice are paramount to ensure a high continence rate, good patient satisfaction, and low postoperative complications. Published data on various MS materials and devices showed reasonable clinical efficacy and safety outcomes, although many of these synthetic MS devices may not be available worldwide due to a lack of regulatory approval in many countries. While the ideal MS is probably yet to be developed, continued scientific advances in slings design, mesh technology, and more refined surgical techniques will improve the continence rate and deliver better safety records.</p><p><strong>Conclusions: </strong>As clinical data matures with longer-term outcomes coupled with advances in scientific designs and technology, the ability to have and select the optimal MS for a particular patient will come to fruition.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11399030/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.21037/tau-23-13\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/tau-23-13","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/5 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
摘要
背景和目的:男性吊衣(MS)的理想适用人群应为轻度至中度压力性尿失禁(SUI)患者。这篇叙述性综述文章对目前商业市场上的 MS 设备进行了评估,并探讨了 MS 作为治疗男性 SUI 的一种有效、安全的替代疗法的作用:主要内容和研究结果:过去二十年来,MS 的设计和技术在科学上取得了长足的进步,对于不需要或不想使用人工尿道括约肌的患者来说,MS 是一种极具吸引力的替代方案。现代 MS 可分为可调式和不可调式两种,通过耻骨后或经尿道(TO)方法放置。要确保高尿失禁率、良好的患者满意度和较低的术后并发症,最重要的是对患者进行严格的选择和咨询,选择具有可靠临床记录的 MS,并进行安全的手术操作。有关各种 MS 材料和装置的已发表数据显示,其临床疗效和安全性均达到了合理水平,但由于许多国家尚未获得监管部门的批准,这些合成 MS 装置可能无法在全球范围内使用。虽然理想的 MS 可能尚未开发出来,但吊衣设计、网眼技术和更精细的手术技术方面的持续科学进步将提高尿失禁率,并提供更好的安全记录:结论:随着临床数据的成熟和长期疗效的显现,以及科学设计和技术的进步,为特定病人设计和选择最合适的 MS 的能力将会实现。
The male slings: an effective and safe alternative surgical treatment to the artificial urinary sphincter for male stress urinary incontinence?-a narrative review.
Background and objective: The ideal candidate for a male sling (MS) should have a mild to moderate degree of stress urinary incontinence (SUI). This narrative review article evaluates the current MS devices in the commercial market and examines the role of MS as an effective and safe alternative treatment option for male SUI.
Methods: The available literature on MS was reviewed and relevant clinical studies pertaining to each MS were summarised with emphasis on device design and technology as well as specific surgical findings relating to clinical outcomes.
Key content and findings: Over the past two decades, there have been considerable scientific advances in MS design and technology, and MS is an attractive alternative for patients who might not require or want an artificial urinary sphincter. The modern MS can be classified as adjustable or non-adjustable types and is placed either through a retropubic or transobturator (TO) approach. Strict patient selection and counselling, selection of MS with proven clinical records, and safe surgical practice are paramount to ensure a high continence rate, good patient satisfaction, and low postoperative complications. Published data on various MS materials and devices showed reasonable clinical efficacy and safety outcomes, although many of these synthetic MS devices may not be available worldwide due to a lack of regulatory approval in many countries. While the ideal MS is probably yet to be developed, continued scientific advances in slings design, mesh technology, and more refined surgical techniques will improve the continence rate and deliver better safety records.
Conclusions: As clinical data matures with longer-term outcomes coupled with advances in scientific designs and technology, the ability to have and select the optimal MS for a particular patient will come to fruition.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.