二维斑点追踪成像在蒽环类药物治疗乳腺癌引起的心脏毒性中的应用

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
ACS Applied Electronic Materials Pub Date : 2024-09-09 eCollection Date: 2024-01-01 DOI:10.7150/jca.98204
Wenjuan Song, Xuejuan Ma, Yue Sun, Liping Liu, Ying Gu, Yue Zhao, Yujia Ye, Yu Wang
{"title":"二维斑点追踪成像在蒽环类药物治疗乳腺癌引起的心脏毒性中的应用","authors":"Wenjuan Song, Xuejuan Ma, Yue Sun, Liping Liu, Ying Gu, Yue Zhao, Yujia Ye, Yu Wang","doi":"10.7150/jca.98204","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> This research was conducted to investigate the monitoring values of routine echocardiography (ECG) and two-dimensional speckle tracking imaging (2D-STI) in cardiotoxicity caused by the treatment of breast carcinoma with anthracyclines (ANTH). <b>Methods:</b> 100 patients with breast carcinoma were selected and enrolled into normal group (n=53 cases) and abnormal group (47 cases) according to whether ECG was abnormal. Routine ECG and 2D-STI were employed for the detection, ECG- and 2D-STI-related parameters were compared, receiver operating characteristic (ROC) curves were drawn, and the clinical application values of monitoring methods for two groups were assessed. <b>Results:</b> Before chemotherapy, no remarkable statistical difference was detected in routine ECG and 2D-STI parameters between normal and abnormal groups (<i>P</i>>0.05). After 6 cycles, E/V value of abnormal group was inferior to that of normal group ((0.93±0.16) vs (1.33±0.23). Besides, longitudinal peak strain (SRI) values of rear wall, front spacer, and rear spacer in abnormal group were inferior to those in normal group (<i>P</i><0.05). Routine ECG combined with 2D-STI had the best predictive effect followed by 2D-STI and routine ECG. <b>Conclusion:</b> To sum up, 2D-STI was a new method for assessing myocardial lesions and possessed significant early clinical monitoring values in cardiotoxicity caused by chemotherapy after the treatment of breast carcinoma with ANTH. It had higher clinical application values than routine ECG.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11414615/pdf/","citationCount":"0","resultStr":"{\"title\":\"Two-dimensional Speckle Tracking Imaging in Cardiotoxicity Caused by Treatment of Breast Carcinoma with Anthracyclines.\",\"authors\":\"Wenjuan Song, Xuejuan Ma, Yue Sun, Liping Liu, Ying Gu, Yue Zhao, Yujia Ye, Yu Wang\",\"doi\":\"10.7150/jca.98204\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objective:</b> This research was conducted to investigate the monitoring values of routine echocardiography (ECG) and two-dimensional speckle tracking imaging (2D-STI) in cardiotoxicity caused by the treatment of breast carcinoma with anthracyclines (ANTH). <b>Methods:</b> 100 patients with breast carcinoma were selected and enrolled into normal group (n=53 cases) and abnormal group (47 cases) according to whether ECG was abnormal. Routine ECG and 2D-STI were employed for the detection, ECG- and 2D-STI-related parameters were compared, receiver operating characteristic (ROC) curves were drawn, and the clinical application values of monitoring methods for two groups were assessed. <b>Results:</b> Before chemotherapy, no remarkable statistical difference was detected in routine ECG and 2D-STI parameters between normal and abnormal groups (<i>P</i>>0.05). After 6 cycles, E/V value of abnormal group was inferior to that of normal group ((0.93±0.16) vs (1.33±0.23). Besides, longitudinal peak strain (SRI) values of rear wall, front spacer, and rear spacer in abnormal group were inferior to those in normal group (<i>P</i><0.05). Routine ECG combined with 2D-STI had the best predictive effect followed by 2D-STI and routine ECG. <b>Conclusion:</b> To sum up, 2D-STI was a new method for assessing myocardial lesions and possessed significant early clinical monitoring values in cardiotoxicity caused by chemotherapy after the treatment of breast carcinoma with ANTH. It had higher clinical application values than routine ECG.</p>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-09-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11414615/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.7150/jca.98204\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.7150/jca.98204","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在探讨常规超声心动图(ECG)和二维斑点追踪成像(2D-STI)对蒽环类药物(ANTH)治疗乳腺癌所致心脏毒性的监测价值。方法:选择 100 例乳腺癌患者,根据心电图是否异常分为正常组(53 例)和异常组(47 例)。采用常规心电图和 2D-STI 进行检测,比较心电图和 2D-STI 相关参数,绘制接收器操作特征曲线(ROC),评估两组监测方法的临床应用价值。结果化疗前,正常组和异常组的常规心电图和二维-STI参数无明显统计学差异(P>0.05)。6 个周期后,异常组的 E/V 值低于正常组((0.93±0.16) vs (1.33±0.23))。此外,异常组的后壁、前隔板和后隔板的纵向峰值应变(SRI)值均低于正常组(PC结论:综上所述,2D-STI 是一种评估心肌病变的新方法,对 ANTH 治疗乳腺癌后化疗引起的心脏毒性具有重要的早期临床监测价值。它比常规心电图具有更高的临床应用价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Two-dimensional Speckle Tracking Imaging in Cardiotoxicity Caused by Treatment of Breast Carcinoma with Anthracyclines.

Objective: This research was conducted to investigate the monitoring values of routine echocardiography (ECG) and two-dimensional speckle tracking imaging (2D-STI) in cardiotoxicity caused by the treatment of breast carcinoma with anthracyclines (ANTH). Methods: 100 patients with breast carcinoma were selected and enrolled into normal group (n=53 cases) and abnormal group (47 cases) according to whether ECG was abnormal. Routine ECG and 2D-STI were employed for the detection, ECG- and 2D-STI-related parameters were compared, receiver operating characteristic (ROC) curves were drawn, and the clinical application values of monitoring methods for two groups were assessed. Results: Before chemotherapy, no remarkable statistical difference was detected in routine ECG and 2D-STI parameters between normal and abnormal groups (P>0.05). After 6 cycles, E/V value of abnormal group was inferior to that of normal group ((0.93±0.16) vs (1.33±0.23). Besides, longitudinal peak strain (SRI) values of rear wall, front spacer, and rear spacer in abnormal group were inferior to those in normal group (P<0.05). Routine ECG combined with 2D-STI had the best predictive effect followed by 2D-STI and routine ECG. Conclusion: To sum up, 2D-STI was a new method for assessing myocardial lesions and possessed significant early clinical monitoring values in cardiotoxicity caused by chemotherapy after the treatment of breast carcinoma with ANTH. It had higher clinical application values than routine ECG.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信