{"title":"在中高度近视患者中,植入式科拉莫晶体与小切口皮瓣摘除术的视觉效果对比:试点研究。","authors":"Rajesh Sinha, Juhi Daga, Pranita Sahay, Vinay Gupta, Tushar Agarwal, Namrata Sharma, Prafulla K Maharana, Sudarshan K Khokhar, Jeewan S Titiyal","doi":"10.4103/IJO.IJO_908_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the visual outcomes of implantable Collamer lens (ICL) with small incision lenticule extraction (SMILE) in cases of moderate-high myopia.</p><p><strong>Methods: </strong>A prospective comparative study was conducted on 60 eyes of 30 patients with moderate-high myopia (-3D to -8D with astigmatism ≤1 D) at a tertiary eye care center. Patients underwent either SMILE or ICL in both eyes and had a postoperative follow-up of 1 year.</p><p><strong>Results: </strong>The manifest refractive spherical equivalent was -5.22 ± 1.05 D and -5.4 ± 1.17 D in the SMILE and ICL groups, respectively ( P = 0.53). The mean sphere and cylinder were comparable between the groups. The mean uncorrected visual acuity improved from 1.18 ± 0.19 logMAR to 0.03 ± 0.07 logMAR in SMILE and 1.14 ± 0.25 logMAR to 0.011 ± 0.04 logMAR in the ICL group. The efficacy for SMILE was 83.3% and that for ICL was 93.3%. Safety and predictability (±0.5D) for both was 100%. A significant increase was observed in ocular aberration with a decrease in modular transfer function in the eyes that underwent SMILE, whereas no significant change in the eyes that underwent ICL. A significant difference was observed in all parameters of ocular aberration except corneal trefoil, corneal astigmatism, and PSF between the two groups at the final follow-up. The contrast sensitivity at final follow-up was higher in ICL cases when compared to SMILE. The quality of vision (QoV) score suggested a better QoV with ICL; however, the difference was not statistically significant.</p><p><strong>Conclusion: </strong>Both SMILE and ICL are safe in patients with moderate-high myopia. The efficacy, contrast sensitivity, and postoperative ocular aberration profile are better in cases undergoing ICL.</p>","PeriodicalId":13329,"journal":{"name":"Indian Journal of Ophthalmology","volume":" ","pages":"115-121"},"PeriodicalIF":2.1000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Visual outcomes with implantable Collamer lens versus small incision lenticule extraction in moderate-high myopia: A pilot study.\",\"authors\":\"Rajesh Sinha, Juhi Daga, Pranita Sahay, Vinay Gupta, Tushar Agarwal, Namrata Sharma, Prafulla K Maharana, Sudarshan K Khokhar, Jeewan S Titiyal\",\"doi\":\"10.4103/IJO.IJO_908_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To compare the visual outcomes of implantable Collamer lens (ICL) with small incision lenticule extraction (SMILE) in cases of moderate-high myopia.</p><p><strong>Methods: </strong>A prospective comparative study was conducted on 60 eyes of 30 patients with moderate-high myopia (-3D to -8D with astigmatism ≤1 D) at a tertiary eye care center. Patients underwent either SMILE or ICL in both eyes and had a postoperative follow-up of 1 year.</p><p><strong>Results: </strong>The manifest refractive spherical equivalent was -5.22 ± 1.05 D and -5.4 ± 1.17 D in the SMILE and ICL groups, respectively ( P = 0.53). The mean sphere and cylinder were comparable between the groups. The mean uncorrected visual acuity improved from 1.18 ± 0.19 logMAR to 0.03 ± 0.07 logMAR in SMILE and 1.14 ± 0.25 logMAR to 0.011 ± 0.04 logMAR in the ICL group. The efficacy for SMILE was 83.3% and that for ICL was 93.3%. Safety and predictability (±0.5D) for both was 100%. A significant increase was observed in ocular aberration with a decrease in modular transfer function in the eyes that underwent SMILE, whereas no significant change in the eyes that underwent ICL. A significant difference was observed in all parameters of ocular aberration except corneal trefoil, corneal astigmatism, and PSF between the two groups at the final follow-up. The contrast sensitivity at final follow-up was higher in ICL cases when compared to SMILE. The quality of vision (QoV) score suggested a better QoV with ICL; however, the difference was not statistically significant.</p><p><strong>Conclusion: </strong>Both SMILE and ICL are safe in patients with moderate-high myopia. The efficacy, contrast sensitivity, and postoperative ocular aberration profile are better in cases undergoing ICL.</p>\",\"PeriodicalId\":13329,\"journal\":{\"name\":\"Indian Journal of Ophthalmology\",\"volume\":\" \",\"pages\":\"115-121\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4103/IJO.IJO_908_24\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/10 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/IJO.IJO_908_24","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/10 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Visual outcomes with implantable Collamer lens versus small incision lenticule extraction in moderate-high myopia: A pilot study.
Purpose: To compare the visual outcomes of implantable Collamer lens (ICL) with small incision lenticule extraction (SMILE) in cases of moderate-high myopia.
Methods: A prospective comparative study was conducted on 60 eyes of 30 patients with moderate-high myopia (-3D to -8D with astigmatism ≤1 D) at a tertiary eye care center. Patients underwent either SMILE or ICL in both eyes and had a postoperative follow-up of 1 year.
Results: The manifest refractive spherical equivalent was -5.22 ± 1.05 D and -5.4 ± 1.17 D in the SMILE and ICL groups, respectively ( P = 0.53). The mean sphere and cylinder were comparable between the groups. The mean uncorrected visual acuity improved from 1.18 ± 0.19 logMAR to 0.03 ± 0.07 logMAR in SMILE and 1.14 ± 0.25 logMAR to 0.011 ± 0.04 logMAR in the ICL group. The efficacy for SMILE was 83.3% and that for ICL was 93.3%. Safety and predictability (±0.5D) for both was 100%. A significant increase was observed in ocular aberration with a decrease in modular transfer function in the eyes that underwent SMILE, whereas no significant change in the eyes that underwent ICL. A significant difference was observed in all parameters of ocular aberration except corneal trefoil, corneal astigmatism, and PSF between the two groups at the final follow-up. The contrast sensitivity at final follow-up was higher in ICL cases when compared to SMILE. The quality of vision (QoV) score suggested a better QoV with ICL; however, the difference was not statistically significant.
Conclusion: Both SMILE and ICL are safe in patients with moderate-high myopia. The efficacy, contrast sensitivity, and postoperative ocular aberration profile are better in cases undergoing ICL.