Yaodong Tang, Teresa Pham, William Pl Bradley, Fiona M Brewster, David J Brewster
{"title":"对维多利亚州部分医院的困难气道推车进行全面审计。","authors":"Yaodong Tang, Teresa Pham, William Pl Bradley, Fiona M Brewster, David J Brewster","doi":"10.1177/0310057X241265722","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to assess the availability, design, and contents of difficult airway trolleys in hospitals in Victoria, Australia. A survey audit was conducted with a 92.3% reply rate, and the responses from 22 major Victorian hospitals were analysed. The results showed that difficult airway trolleys were available in 100% of operating theatres, emergency departments and intensive care units, and the rate of standardisation was high. Compliance with recommended design features and resources was on average 68.3%. There was no significant difference in the compliance rate of major tertiary centres compared with other hospitals. The carriage of non-essential items was reduced compared with earlier audits. However, there was heterogeneity in the brands of supraglottic airway devices, videolaryngoscopes and cognitive aids used. The study highlights the need for ongoing improvement to the organization and content of difficult airway trolleys, and for further discussion regarding the safety of equipment variation across institutions.</p>","PeriodicalId":7746,"journal":{"name":"Anaesthesia and Intensive Care","volume":" ","pages":"407-414"},"PeriodicalIF":1.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A comprehensive audit of difficult airway trolleys in selected Victorian hospitals.\",\"authors\":\"Yaodong Tang, Teresa Pham, William Pl Bradley, Fiona M Brewster, David J Brewster\",\"doi\":\"10.1177/0310057X241265722\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aimed to assess the availability, design, and contents of difficult airway trolleys in hospitals in Victoria, Australia. A survey audit was conducted with a 92.3% reply rate, and the responses from 22 major Victorian hospitals were analysed. The results showed that difficult airway trolleys were available in 100% of operating theatres, emergency departments and intensive care units, and the rate of standardisation was high. Compliance with recommended design features and resources was on average 68.3%. There was no significant difference in the compliance rate of major tertiary centres compared with other hospitals. The carriage of non-essential items was reduced compared with earlier audits. However, there was heterogeneity in the brands of supraglottic airway devices, videolaryngoscopes and cognitive aids used. The study highlights the need for ongoing improvement to the organization and content of difficult airway trolleys, and for further discussion regarding the safety of equipment variation across institutions.</p>\",\"PeriodicalId\":7746,\"journal\":{\"name\":\"Anaesthesia and Intensive Care\",\"volume\":\" \",\"pages\":\"407-414\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anaesthesia and Intensive Care\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/0310057X241265722\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/23 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anaesthesia and Intensive Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/0310057X241265722","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/23 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
A comprehensive audit of difficult airway trolleys in selected Victorian hospitals.
This study aimed to assess the availability, design, and contents of difficult airway trolleys in hospitals in Victoria, Australia. A survey audit was conducted with a 92.3% reply rate, and the responses from 22 major Victorian hospitals were analysed. The results showed that difficult airway trolleys were available in 100% of operating theatres, emergency departments and intensive care units, and the rate of standardisation was high. Compliance with recommended design features and resources was on average 68.3%. There was no significant difference in the compliance rate of major tertiary centres compared with other hospitals. The carriage of non-essential items was reduced compared with earlier audits. However, there was heterogeneity in the brands of supraglottic airway devices, videolaryngoscopes and cognitive aids used. The study highlights the need for ongoing improvement to the organization and content of difficult airway trolleys, and for further discussion regarding the safety of equipment variation across institutions.
期刊介绍:
Anaesthesia and Intensive Care is an international journal publishing timely, peer reviewed articles that have educational value and scientific merit for clinicians and researchers associated with anaesthesia, intensive care medicine, and pain medicine.