Cleber Paradzinski Cavalheiro, Carolina Lopes da Silva, Vicente Castelo Branco Leitune, Fernando Borba de Araujo, José Carlos Pettorossi Imparato, Tathiane Larissa Lenzi
{"title":"可流动树脂复合材料是否可用于乳牙咬合近端修复?断裂强度分析","authors":"Cleber Paradzinski Cavalheiro, Carolina Lopes da Silva, Vicente Castelo Branco Leitune, Fernando Borba de Araujo, José Carlos Pettorossi Imparato, Tathiane Larissa Lenzi","doi":"10.1111/ipd.13270","DOIUrl":null,"url":null,"abstract":"BackgroundUse of flowable resin composites for ocluso‐proximal restorations in primary molars could improve cervical adaptation, and reduce the failure risk.AimTo investigate the fracture strength of occluso‐proximal restorations in primary teeth using different flowable resin composites (as an intermediate layer or entire cavity) and a conventional resin composite (incremental technique).DesignTwo standardized occluso‐proximal cavities were prepared on mesial and distal surfaces of 50 sound primary molars. The teeth were randomly assigned into five groups (<jats:italic>n</jats:italic> = 10): 2 mm Filtek Bulk Fill Flow + Z350 XT; 4 mm Filtek Bulk Fill Flow; 2 mm Z350 XT Flow + Z350 XT; 4 mm Z350 XT Flow; and Z350 XT inserted by incremental technique. All restored teeth were subjected to cariogenic challenge and then submitted to fracture strength test. The failure pattern of each specimen was categorized as reparable or irreparable/need for replacement based on the World Dental Federation (FDI) criteria. Fracture strength means were submitted to one‐way ANOVA and Tukey's post hoc tests. Failure pattern was analyzed descriptively.ResultsThere was no statistically significant difference on fracture strength among groups (<jats:italic>p</jats:italic> = .48). A similar distribution of reparable (35%–40%) and irreparable (60%–65%) failures was observed among groups.ConclusionBased on a laboratorial setting, the use of different flowable resin composites (as an intermediate layer or entire cavity) may be an option to restore occluso‐proximal cavities in primary molars.","PeriodicalId":14268,"journal":{"name":"International journal of paediatric dentistry","volume":"50 1","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Is use of flowable resin composite an option for occluso‐proximal restorations in primary teeth? A fracture strength analysis\",\"authors\":\"Cleber Paradzinski Cavalheiro, Carolina Lopes da Silva, Vicente Castelo Branco Leitune, Fernando Borba de Araujo, José Carlos Pettorossi Imparato, Tathiane Larissa Lenzi\",\"doi\":\"10.1111/ipd.13270\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BackgroundUse of flowable resin composites for ocluso‐proximal restorations in primary molars could improve cervical adaptation, and reduce the failure risk.AimTo investigate the fracture strength of occluso‐proximal restorations in primary teeth using different flowable resin composites (as an intermediate layer or entire cavity) and a conventional resin composite (incremental technique).DesignTwo standardized occluso‐proximal cavities were prepared on mesial and distal surfaces of 50 sound primary molars. The teeth were randomly assigned into five groups (<jats:italic>n</jats:italic> = 10): 2 mm Filtek Bulk Fill Flow + Z350 XT; 4 mm Filtek Bulk Fill Flow; 2 mm Z350 XT Flow + Z350 XT; 4 mm Z350 XT Flow; and Z350 XT inserted by incremental technique. All restored teeth were subjected to cariogenic challenge and then submitted to fracture strength test. The failure pattern of each specimen was categorized as reparable or irreparable/need for replacement based on the World Dental Federation (FDI) criteria. Fracture strength means were submitted to one‐way ANOVA and Tukey's post hoc tests. Failure pattern was analyzed descriptively.ResultsThere was no statistically significant difference on fracture strength among groups (<jats:italic>p</jats:italic> = .48). A similar distribution of reparable (35%–40%) and irreparable (60%–65%) failures was observed among groups.ConclusionBased on a laboratorial setting, the use of different flowable resin composites (as an intermediate layer or entire cavity) may be an option to restore occluso‐proximal cavities in primary molars.\",\"PeriodicalId\":14268,\"journal\":{\"name\":\"International journal of paediatric dentistry\",\"volume\":\"50 1\",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-09-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of paediatric dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/ipd.13270\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of paediatric dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/ipd.13270","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
摘要
目的研究使用不同的可流动树脂复合材料(作为中间层或整个牙洞)和传统树脂复合材料(增量技术)进行基牙咬合近端修复的断裂强度。这些牙齿被随机分为五组(n = 10):2 mm Filtek Bulill Flow + Z350 XT;4 mm Filtek Bulill Flow;2 mm Z350 XT Flow + Z350 XT;4 mm Z350 XT Flow;Z350 XT 以增量技术插入。所有修复后的牙齿都接受了致龋挑战,然后进行了断裂强度测试。根据世界牙科联盟(FDI)的标准,每个试样的失效模式被分为可修复或不可修复/需要更换。对断裂强度平均值进行单因素方差分析和 Tukey 后检验。结果各组间的骨折强度差异无统计学意义(p = .48)。结论基于实验室环境,使用不同的可流动树脂复合材料(作为中间层或整个龋洞)可能是修复初级磨牙咬合近端龋洞的一种选择。
Is use of flowable resin composite an option for occluso‐proximal restorations in primary teeth? A fracture strength analysis
BackgroundUse of flowable resin composites for ocluso‐proximal restorations in primary molars could improve cervical adaptation, and reduce the failure risk.AimTo investigate the fracture strength of occluso‐proximal restorations in primary teeth using different flowable resin composites (as an intermediate layer or entire cavity) and a conventional resin composite (incremental technique).DesignTwo standardized occluso‐proximal cavities were prepared on mesial and distal surfaces of 50 sound primary molars. The teeth were randomly assigned into five groups (n = 10): 2 mm Filtek Bulk Fill Flow + Z350 XT; 4 mm Filtek Bulk Fill Flow; 2 mm Z350 XT Flow + Z350 XT; 4 mm Z350 XT Flow; and Z350 XT inserted by incremental technique. All restored teeth were subjected to cariogenic challenge and then submitted to fracture strength test. The failure pattern of each specimen was categorized as reparable or irreparable/need for replacement based on the World Dental Federation (FDI) criteria. Fracture strength means were submitted to one‐way ANOVA and Tukey's post hoc tests. Failure pattern was analyzed descriptively.ResultsThere was no statistically significant difference on fracture strength among groups (p = .48). A similar distribution of reparable (35%–40%) and irreparable (60%–65%) failures was observed among groups.ConclusionBased on a laboratorial setting, the use of different flowable resin composites (as an intermediate layer or entire cavity) may be an option to restore occluso‐proximal cavities in primary molars.
期刊介绍:
The International Journal of Paediatric Dentistry was formed in 1991 by the merger of the Journals of the International Association of Paediatric Dentistry and the British Society of Paediatric Dentistry and is published bi-monthly. It has true international scope and aims to promote the highest standard of education, practice and research in paediatric dentistry world-wide.
International Journal of Paediatric Dentistry publishes papers on all aspects of paediatric dentistry including: growth and development, behaviour management, diagnosis, prevention, restorative treatment and issue relating to medically compromised children or those with disabilities. This peer-reviewed journal features scientific articles, reviews, case reports, clinical techniques, short communications and abstracts of current paediatric dental research. Analytical studies with a scientific novelty value are preferred to descriptive studies. Case reports illustrating unusual conditions and clinically relevant observations are acceptable but must be of sufficiently high quality to be considered for publication; particularly the illustrative material must be of the highest quality.