利用高通量 HVE 气体接口系统对二氧化碳样品进行 14C AMS 测量

IF 2 3区 地球科学 Q2 GEOCHEMISTRY & GEOPHYSICS
Radiocarbon Pub Date : 2024-09-18 DOI:10.1017/rdc.2024.60
G Scognamiglio, M Klein, A Stolz, R Walet, D Mous
{"title":"利用高通量 HVE 气体接口系统对二氧化碳样品进行 14C AMS 测量","authors":"G Scognamiglio, M Klein, A Stolz, R Walet, D Mous","doi":"10.1017/rdc.2024.60","DOIUrl":null,"url":null,"abstract":"The newly designed HVE gas interface enables the AMS measurement of carbon samples in CO<jats:sub>2</jats:sub> form. The CO<jats:sub>2</jats:sub>, e.g. resulting from the sample combustion in an elemental analyzer, is adsorbed in a zeolite trap and subsequently transferred to a motor-driven syringe. Once diluted with He, the gas mixture is transferred into the ion source of the AMS system. A carbon ion beam is formed in the ion source and mass-analyzed by the AMS system, resulting in <jats:sup>13</jats:sup>C/<jats:sup>12</jats:sup>C and <jats:sup>14</jats:sup>C/<jats:sup>12</jats:sup>C isotopic ratios. The HVE gas interface features two traps and two syringes to maximize the sample throughput, which results in more than 10 samples per hour. The first performance results of CO<jats:sub>2</jats:sub> gas sample AMS measurements that were performed with the HVE gas interface in combination with the HVE 210 kV AMS system are presented in this paper. The measurements show that the gas interface contribution to the <jats:sup>14</jats:sup>C/<jats:sup>12</jats:sup>C background is in the 10<jats:sup>–15</jats:sup> level and to the precision is at or below 1%.","PeriodicalId":21020,"journal":{"name":"Radiocarbon","volume":"54 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"14C AMS measurement of CO2 samples with the high throughput HVE gas interface system\",\"authors\":\"G Scognamiglio, M Klein, A Stolz, R Walet, D Mous\",\"doi\":\"10.1017/rdc.2024.60\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The newly designed HVE gas interface enables the AMS measurement of carbon samples in CO<jats:sub>2</jats:sub> form. The CO<jats:sub>2</jats:sub>, e.g. resulting from the sample combustion in an elemental analyzer, is adsorbed in a zeolite trap and subsequently transferred to a motor-driven syringe. Once diluted with He, the gas mixture is transferred into the ion source of the AMS system. A carbon ion beam is formed in the ion source and mass-analyzed by the AMS system, resulting in <jats:sup>13</jats:sup>C/<jats:sup>12</jats:sup>C and <jats:sup>14</jats:sup>C/<jats:sup>12</jats:sup>C isotopic ratios. The HVE gas interface features two traps and two syringes to maximize the sample throughput, which results in more than 10 samples per hour. The first performance results of CO<jats:sub>2</jats:sub> gas sample AMS measurements that were performed with the HVE gas interface in combination with the HVE 210 kV AMS system are presented in this paper. The measurements show that the gas interface contribution to the <jats:sup>14</jats:sup>C/<jats:sup>12</jats:sup>C background is in the 10<jats:sup>–15</jats:sup> level and to the precision is at or below 1%.\",\"PeriodicalId\":21020,\"journal\":{\"name\":\"Radiocarbon\",\"volume\":\"54 1\",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-09-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiocarbon\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.1017/rdc.2024.60\",\"RegionNum\":3,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"GEOCHEMISTRY & GEOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiocarbon","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.1017/rdc.2024.60","RegionNum":3,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GEOCHEMISTRY & GEOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

新设计的 HVE 气体接口可对二氧化碳形式的碳样品进行 AMS 测量。二氧化碳(例如在元素分析仪中样品燃烧产生的二氧化碳)被吸附在沸石捕集器中,随后被输送到电机驱动的注射器中。用 He 稀释后,气体混合物被转移到 AMS 系统的离子源中。碳离子束在离子源中形成,由 AMS 系统进行质量分析,得出 13C/12C 和 14C/12C 同位素比值。HVE 气体接口具有两个捕集器和两个注射器,可最大限度地提高样品吞吐量,每小时可采集 10 多个样品。本文介绍了使用 HVE 气体界面结合 HVE 210 kV AMS 系统进行的二氧化碳气体样品 AMS 测量的首批性能结果。测量结果表明,气体界面对 14C/12C 背景的贡献在 10-15 级,对精度的贡献在 1%或以下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
14C AMS measurement of CO2 samples with the high throughput HVE gas interface system
The newly designed HVE gas interface enables the AMS measurement of carbon samples in CO2 form. The CO2, e.g. resulting from the sample combustion in an elemental analyzer, is adsorbed in a zeolite trap and subsequently transferred to a motor-driven syringe. Once diluted with He, the gas mixture is transferred into the ion source of the AMS system. A carbon ion beam is formed in the ion source and mass-analyzed by the AMS system, resulting in 13C/12C and 14C/12C isotopic ratios. The HVE gas interface features two traps and two syringes to maximize the sample throughput, which results in more than 10 samples per hour. The first performance results of CO2 gas sample AMS measurements that were performed with the HVE gas interface in combination with the HVE 210 kV AMS system are presented in this paper. The measurements show that the gas interface contribution to the 14C/12C background is in the 10–15 level and to the precision is at or below 1%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiocarbon
Radiocarbon 地学-地球化学与地球物理
CiteScore
16.20
自引率
6.00%
发文量
85
审稿时长
6-12 weeks
期刊介绍: Radiocarbon serves as the leading international journal for technical and interpretive articles, date lists, and advancements in 14C and other radioisotopes relevant to archaeological, geophysical, oceanographic, and related dating methods. Established in 1959, it has published numerous seminal works and hosts the triennial International Radiocarbon Conference proceedings. The journal also features occasional special issues. Submissions encompass regular articles such as research reports, technical descriptions, and date lists, along with comments, letters to the editor, book reviews, and laboratory lists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信