{"title":"对钚中 5f 占位的重新评估","authors":"JG Tobin","doi":"10.1016/j.elspec.2024.147478","DOIUrl":null,"url":null,"abstract":"<div><p>A detailed spectroscopic simulation of the original Pu N<sub>4,5</sub> and O<sub>4,5</sub> X-Ray Absorption Spectroscopy (XAS) has been performed. Additionally, a fundamental flaw in the Electron Energy Loss Spectroscopy (EELS) measurement has been corrected. Thus, the determination of the 5f occupation (n) in elemental Pu has been re-evaluated with the result that n = 5.0 ± 0.1 for αPu and n = 4.9 ± 0.2 for δPu. These values are significantly lower than the value of ∼5½ that was propagated earlier.</p></div>","PeriodicalId":15726,"journal":{"name":"Journal of Electron Spectroscopy and Related Phenomena","volume":"276 ","pages":"Article 147478"},"PeriodicalIF":1.8000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A reassessment of 5f occupation in plutonium\",\"authors\":\"JG Tobin\",\"doi\":\"10.1016/j.elspec.2024.147478\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A detailed spectroscopic simulation of the original Pu N<sub>4,5</sub> and O<sub>4,5</sub> X-Ray Absorption Spectroscopy (XAS) has been performed. Additionally, a fundamental flaw in the Electron Energy Loss Spectroscopy (EELS) measurement has been corrected. Thus, the determination of the 5f occupation (n) in elemental Pu has been re-evaluated with the result that n = 5.0 ± 0.1 for αPu and n = 4.9 ± 0.2 for δPu. These values are significantly lower than the value of ∼5½ that was propagated earlier.</p></div>\",\"PeriodicalId\":15726,\"journal\":{\"name\":\"Journal of Electron Spectroscopy and Related Phenomena\",\"volume\":\"276 \",\"pages\":\"Article 147478\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electron Spectroscopy and Related Phenomena\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0368204824000616\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SPECTROSCOPY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electron Spectroscopy and Related Phenomena","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0368204824000616","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 0
摘要
对原始钚 N4,5 和 O4,5 X 射线吸收光谱(XAS)进行了详细的光谱模拟。此外,还纠正了电子能量损失光谱(EELS)测量中的一个基本缺陷。因此,对元素钚中 5f 占位 (n) 的测定进行了重新评估,结果是 αPu 的 n = 5.0 ± 0.1,δPu 的 n = 4.9 ± 0.2。这些数值明显低于先前传播的 ∼5½ 值。
A detailed spectroscopic simulation of the original Pu N4,5 and O4,5 X-Ray Absorption Spectroscopy (XAS) has been performed. Additionally, a fundamental flaw in the Electron Energy Loss Spectroscopy (EELS) measurement has been corrected. Thus, the determination of the 5f occupation (n) in elemental Pu has been re-evaluated with the result that n = 5.0 ± 0.1 for αPu and n = 4.9 ± 0.2 for δPu. These values are significantly lower than the value of ∼5½ that was propagated earlier.
期刊介绍:
The Journal of Electron Spectroscopy and Related Phenomena publishes experimental, theoretical and applied work in the field of electron spectroscopy and electronic structure, involving techniques which use high energy photons (>10 eV) or electrons as probes or detected particles in the investigation.