锝和碘实验中过滤的重要性

IF 1.5 3区 化学 Q3 CHEMISTRY, ANALYTICAL
Ilana Szlamkowicz, Jordan Stanberry, Travis Hager, Lucy Hunley, Vasileios Anagnostopoulos
{"title":"锝和碘实验中过滤的重要性","authors":"Ilana Szlamkowicz,&nbsp;Jordan Stanberry,&nbsp;Travis Hager,&nbsp;Lucy Hunley,&nbsp;Vasileios Anagnostopoulos","doi":"10.1007/s10967-024-09689-y","DOIUrl":null,"url":null,"abstract":"<div><p>Filter use in experiments is often unspecified, potentially affecting results. In this study, six different filters were investigated for technetium and iodine. Technetium was evaluated at pH 2.5, 6, and 11 for two concentrations. Three oxidation states of iodine (iodide, molecular iodine, and iodate) were evaluated at pH 7 for two concentration levels. The results obtained were analyzed using a t-test to determine if it was statistically different than an unfiltered sample. The experimental results are combined with a literature review highlighting the inconsistency of filter reporting in manuscripts, as well as not accounting for analyte loss on filters used.</p></div>","PeriodicalId":661,"journal":{"name":"Journal of Radioanalytical and Nuclear Chemistry","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The importance of filtration in technetium and iodine experiments\",\"authors\":\"Ilana Szlamkowicz,&nbsp;Jordan Stanberry,&nbsp;Travis Hager,&nbsp;Lucy Hunley,&nbsp;Vasileios Anagnostopoulos\",\"doi\":\"10.1007/s10967-024-09689-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Filter use in experiments is often unspecified, potentially affecting results. In this study, six different filters were investigated for technetium and iodine. Technetium was evaluated at pH 2.5, 6, and 11 for two concentrations. Three oxidation states of iodine (iodide, molecular iodine, and iodate) were evaluated at pH 7 for two concentration levels. The results obtained were analyzed using a t-test to determine if it was statistically different than an unfiltered sample. The experimental results are combined with a literature review highlighting the inconsistency of filter reporting in manuscripts, as well as not accounting for analyte loss on filters used.</p></div>\",\"PeriodicalId\":661,\"journal\":{\"name\":\"Journal of Radioanalytical and Nuclear Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Radioanalytical and Nuclear Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10967-024-09689-y\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radioanalytical and Nuclear Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s10967-024-09689-y","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

实验中使用的过滤器往往不明确,可能会影响实验结果。在这项研究中,对六种不同的过滤器进行了锝和碘的研究。对 pH 值为 2.5、6 和 11 的两种浓度的锝进行了评估。碘的三种氧化态(碘化物、分子碘和碘酸根)在 pH 值为 7 的两种浓度水平下进行了评估。所得结果通过 t 检验进行分析,以确定与未经过滤的样本相比是否存在统计学差异。实验结果与文献综述相结合,强调了手稿中过滤器报告的不一致性,以及未考虑所用过滤器上分析物的损失。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The importance of filtration in technetium and iodine experiments

Filter use in experiments is often unspecified, potentially affecting results. In this study, six different filters were investigated for technetium and iodine. Technetium was evaluated at pH 2.5, 6, and 11 for two concentrations. Three oxidation states of iodine (iodide, molecular iodine, and iodate) were evaluated at pH 7 for two concentration levels. The results obtained were analyzed using a t-test to determine if it was statistically different than an unfiltered sample. The experimental results are combined with a literature review highlighting the inconsistency of filter reporting in manuscripts, as well as not accounting for analyte loss on filters used.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.80
自引率
18.80%
发文量
504
审稿时长
2.2 months
期刊介绍: An international periodical publishing original papers, letters, review papers and short communications on nuclear chemistry. The subjects covered include: Nuclear chemistry, Radiochemistry, Radiation chemistry, Radiobiological chemistry, Environmental radiochemistry, Production and control of radioisotopes and labelled compounds, Nuclear power plant chemistry, Nuclear fuel chemistry, Radioanalytical chemistry, Radiation detection and measurement, Nuclear instrumentation and automation, etc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信