{"title":"解决内镜超声引导下胰管引流支架移位问题,避免再次穿刺","authors":"Kazuki Hama,&nbsp;Reina Tanaka,&nbsp;Takao Itoi","doi":"10.1111/den.14906","DOIUrl":null,"url":null,"abstract":"<p>Endoscopic ultrasound (EUS)-guided drainage effectively treats difficult transpapillary drainage.<span><sup>1, 2</sup></span> However, EUS-guided pancreatic duct drainage (EUS-PD) is technically challenging, as repuncture should be avoided to prevent pancreatic fluid leakage; we describe a technique for EUS-PD stent migration that enables us to avoid repuncture (Video S1).<span><sup>3</sup></span> A 54-year-old woman, who underwent pancreaticoduodenectomy for pancreatic cancer, experienced recurrent cholangitis and pancreatic stones due to anastomotic stenosis. Endoscopic drainage using a single-balloon enteroscope (SIF-H290S; Olympus, Tokyo, Japan) was attempted, but identifying the pancreatic duct orifice was difficult. Therefore, EUS-PD was performed to secure the route for stone removal. A 19G needle (EZ shot 3 plus; Olympus) was used to puncture the dilated pancreatic duct at the tail. The drill dilator (Tornus ES; Olympus) could not pass the stone. A 4 mm dilating balloon (REN TYPE-IT; Kaneka, Osaka, Japan) was used. After adequate dilation, a 7Fr plastic stent (TYPE IT; Gadelius Medical, Tokyo, Japan) was deployed, but its tip failed to cross the stone and anastomosis, so the stent was placed in the main pancreatic duct proximal to the stone.<span><sup>4</sup></span> Vomiting and fever occurred postprocedure, and radiography revealed stent migration into the esophagus. However, computed tomography revealed the stent tip barely lodged in the pancreatic duct owing to the large flap. Therefore, using a side-viewing duodenoscope (TJF-260 V; Olympus), a guidewire (VisiGlide II; Olympus) was successfully inserted through the stent flap and guided into the jejunum. The stent was removed using forceps (Figs 1, 2). The tract and anastomotic site were sufficiently dilated using a drill dilator, and a 6 mm fully covered self-expandable metal stent (EGIS biliary stent, 6 × 10 mm; SB-Kawsumi, Kanagawa, Japan) was successfully placed. One month later, the stone was successfully removed by the EUS-PD route. A plastic stent has two large flaps at its tip, and even if it migrates, the flap may remain in the pancreas.</p><p>Author T.I. received honoraria for his lectures from Olympus and Boston Scientific. The other authors declare no conflict of interest for this article.</p>","PeriodicalId":159,"journal":{"name":"Digestive Endoscopy","volume":"36 11","pages":"1288-1289"},"PeriodicalIF":5.0000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/den.14906","citationCount":"0","resultStr":"{\"title\":\"Troubleshooting the migration of endoscopic ultrasound-guided pancreatic duct drainage stent to avoid repuncture\",\"authors\":\"Kazuki Hama,&nbsp;Reina Tanaka,&nbsp;Takao Itoi\",\"doi\":\"10.1111/den.14906\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Endoscopic ultrasound (EUS)-guided drainage effectively treats difficult transpapillary drainage.<span><sup>1, 2</sup></span> However, EUS-guided pancreatic duct drainage (EUS-PD) is technically challenging, as repuncture should be avoided to prevent pancreatic fluid leakage; we describe a technique for EUS-PD stent migration that enables us to avoid repuncture (Video S1).<span><sup>3</sup></span> A 54-year-old woman, who underwent pancreaticoduodenectomy for pancreatic cancer, experienced recurrent cholangitis and pancreatic stones due to anastomotic stenosis. Endoscopic drainage using a single-balloon enteroscope (SIF-H290S; Olympus, Tokyo, Japan) was attempted, but identifying the pancreatic duct orifice was difficult. Therefore, EUS-PD was performed to secure the route for stone removal. A 19G needle (EZ shot 3 plus; Olympus) was used to puncture the dilated pancreatic duct at the tail. The drill dilator (Tornus ES; Olympus) could not pass the stone. A 4 mm dilating balloon (REN TYPE-IT; Kaneka, Osaka, Japan) was used. After adequate dilation, a 7Fr plastic stent (TYPE IT; Gadelius Medical, Tokyo, Japan) was deployed, but its tip failed to cross the stone and anastomosis, so the stent was placed in the main pancreatic duct proximal to the stone.<span><sup>4</sup></span> Vomiting and fever occurred postprocedure, and radiography revealed stent migration into the esophagus. However, computed tomography revealed the stent tip barely lodged in the pancreatic duct owing to the large flap. Therefore, using a side-viewing duodenoscope (TJF-260 V; Olympus), a guidewire (VisiGlide II; Olympus) was successfully inserted through the stent flap and guided into the jejunum. The stent was removed using forceps (Figs 1, 2). The tract and anastomotic site were sufficiently dilated using a drill dilator, and a 6 mm fully covered self-expandable metal stent (EGIS biliary stent, 6 × 10 mm; SB-Kawsumi, Kanagawa, Japan) was successfully placed. One month later, the stone was successfully removed by the EUS-PD route. A plastic stent has two large flaps at its tip, and even if it migrates, the flap may remain in the pancreas.</p><p>Author T.I. received honoraria for his lectures from Olympus and Boston Scientific. The other authors declare no conflict of interest for this article.</p>\",\"PeriodicalId\":159,\"journal\":{\"name\":\"Digestive Endoscopy\",\"volume\":\"36 11\",\"pages\":\"1288-1289\"},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2024-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1111/den.14906\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digestive Endoscopy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/den.14906\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digestive Endoscopy","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/den.14906","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

观看本文视频。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Troubleshooting the migration of endoscopic ultrasound-guided pancreatic duct drainage stent to avoid repuncture

Troubleshooting the migration of endoscopic ultrasound-guided pancreatic duct drainage stent to avoid repuncture

Endoscopic ultrasound (EUS)-guided drainage effectively treats difficult transpapillary drainage.1, 2 However, EUS-guided pancreatic duct drainage (EUS-PD) is technically challenging, as repuncture should be avoided to prevent pancreatic fluid leakage; we describe a technique for EUS-PD stent migration that enables us to avoid repuncture (Video S1).3 A 54-year-old woman, who underwent pancreaticoduodenectomy for pancreatic cancer, experienced recurrent cholangitis and pancreatic stones due to anastomotic stenosis. Endoscopic drainage using a single-balloon enteroscope (SIF-H290S; Olympus, Tokyo, Japan) was attempted, but identifying the pancreatic duct orifice was difficult. Therefore, EUS-PD was performed to secure the route for stone removal. A 19G needle (EZ shot 3 plus; Olympus) was used to puncture the dilated pancreatic duct at the tail. The drill dilator (Tornus ES; Olympus) could not pass the stone. A 4 mm dilating balloon (REN TYPE-IT; Kaneka, Osaka, Japan) was used. After adequate dilation, a 7Fr plastic stent (TYPE IT; Gadelius Medical, Tokyo, Japan) was deployed, but its tip failed to cross the stone and anastomosis, so the stent was placed in the main pancreatic duct proximal to the stone.4 Vomiting and fever occurred postprocedure, and radiography revealed stent migration into the esophagus. However, computed tomography revealed the stent tip barely lodged in the pancreatic duct owing to the large flap. Therefore, using a side-viewing duodenoscope (TJF-260 V; Olympus), a guidewire (VisiGlide II; Olympus) was successfully inserted through the stent flap and guided into the jejunum. The stent was removed using forceps (Figs 1, 2). The tract and anastomotic site were sufficiently dilated using a drill dilator, and a 6 mm fully covered self-expandable metal stent (EGIS biliary stent, 6 × 10 mm; SB-Kawsumi, Kanagawa, Japan) was successfully placed. One month later, the stone was successfully removed by the EUS-PD route. A plastic stent has two large flaps at its tip, and even if it migrates, the flap may remain in the pancreas.

Author T.I. received honoraria for his lectures from Olympus and Boston Scientific. The other authors declare no conflict of interest for this article.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Digestive Endoscopy
Digestive Endoscopy 医学-外科
CiteScore
10.10
自引率
15.10%
发文量
291
审稿时长
6-12 weeks
期刊介绍: Digestive Endoscopy (DEN) is the official journal of the Japan Gastroenterological Endoscopy Society, the Asian Pacific Society for Digestive Endoscopy and the World Endoscopy Organization. Digestive Endoscopy serves as a medium for presenting original articles that offer significant contributions to knowledge in the broad field of endoscopy. The Journal also includes Reviews, Original Articles, How I Do It, Case Reports (only of exceptional interest and novelty are accepted), Letters, Techniques and Images, abstracts and news items that may be of interest to endoscopists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信