{"title":"空气冷却双级 ORC 地热发电站性能评估中的并网光伏系统,案例研究:苏丹希萨尔 GPP-2","authors":"Şeyma Kaçmaz, Havva Demirpolat","doi":"10.1002/ep.14460","DOIUrl":null,"url":null,"abstract":"<p>Many factors determine the percentage of parasitic load of the geothermal power plant. Domestic consumption accounts for about 20–25 per cent of total production in low-temperature geothermal power plants. As a case study, the ratio of a 1 MW grid-connected PV system to the internal consumption of the Sultanhisar GPP-2 and its effect on increasing the efficiency of the system have been examined. The current production of the power plant has been modeled thermodynamically with the parameters taken from the plant, and the efficiency of the system has been calculated. Sultanhisar GPP-2, which operates at a geothermal well temperature of 140.2°C and a net efficiency of 6.28%, has a domestic consumption to production ratio of around 25%. The installation of a 1 MW PV system is expected to produce 2140MWh per year, equivalent to 7% of the internal energy consumption.</p>","PeriodicalId":11701,"journal":{"name":"Environmental Progress & Sustainable Energy","volume":"43 6","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2024-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Grid-connected PV system in air cooled double-stage ORC geothermal power plant performance evaluation, case study: Sultanhisar GPP-2\",\"authors\":\"Şeyma Kaçmaz, Havva Demirpolat\",\"doi\":\"10.1002/ep.14460\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Many factors determine the percentage of parasitic load of the geothermal power plant. Domestic consumption accounts for about 20–25 per cent of total production in low-temperature geothermal power plants. As a case study, the ratio of a 1 MW grid-connected PV system to the internal consumption of the Sultanhisar GPP-2 and its effect on increasing the efficiency of the system have been examined. The current production of the power plant has been modeled thermodynamically with the parameters taken from the plant, and the efficiency of the system has been calculated. Sultanhisar GPP-2, which operates at a geothermal well temperature of 140.2°C and a net efficiency of 6.28%, has a domestic consumption to production ratio of around 25%. The installation of a 1 MW PV system is expected to produce 2140MWh per year, equivalent to 7% of the internal energy consumption.</p>\",\"PeriodicalId\":11701,\"journal\":{\"name\":\"Environmental Progress & Sustainable Energy\",\"volume\":\"43 6\",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-08-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Environmental Progress & Sustainable Energy\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/ep.14460\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, CHEMICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Progress & Sustainable Energy","FirstCategoryId":"93","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ep.14460","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
Grid-connected PV system in air cooled double-stage ORC geothermal power plant performance evaluation, case study: Sultanhisar GPP-2
Many factors determine the percentage of parasitic load of the geothermal power plant. Domestic consumption accounts for about 20–25 per cent of total production in low-temperature geothermal power plants. As a case study, the ratio of a 1 MW grid-connected PV system to the internal consumption of the Sultanhisar GPP-2 and its effect on increasing the efficiency of the system have been examined. The current production of the power plant has been modeled thermodynamically with the parameters taken from the plant, and the efficiency of the system has been calculated. Sultanhisar GPP-2, which operates at a geothermal well temperature of 140.2°C and a net efficiency of 6.28%, has a domestic consumption to production ratio of around 25%. The installation of a 1 MW PV system is expected to produce 2140MWh per year, equivalent to 7% of the internal energy consumption.
期刊介绍:
Environmental Progress , a quarterly publication of the American Institute of Chemical Engineers, reports on critical issues like remediation and treatment of solid or aqueous wastes, air pollution, sustainability, and sustainable energy. Each issue helps chemical engineers (and those in related fields) stay on top of technological advances in all areas associated with the environment through feature articles, updates, book and software reviews, and editorials.