Matheus Akira Sakurada DDS, MSc , Luiz Eduardo Gregoris Rabelo DDS, MSc, PhD , Ivonete Barreto Haagsma DDS , Luis Carlos do Carmo Filho DDS, MSc, PhD , Carlos Estrela DDS, MSc, PhD , Isabela Reginaldo DDS , Thais Marques Simek Vega Gonçalves DDS, MSc, PhD
{"title":"减少模糊伪影过滤器对植入物尺寸分析的影响","authors":"Matheus Akira Sakurada DDS, MSc , Luiz Eduardo Gregoris Rabelo DDS, MSc, PhD , Ivonete Barreto Haagsma DDS , Luis Carlos do Carmo Filho DDS, MSc, PhD , Carlos Estrela DDS, MSc, PhD , Isabela Reginaldo DDS , Thais Marques Simek Vega Gonçalves DDS, MSc, PhD","doi":"10.1016/j.oooo.2024.08.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To assess the effect of a blooming artifact reduction (BAR) filter on cone beam computed tomography (CBCT) images in the dimensional analysis of dental implants.</div></div><div><h3>Study Design</h3><div>Six types of implants (<em>n</em> = 5 for each type) composed of titanium (3 types), titanium-zirconia alloy, zirconium oxide, and titanium-aluminum-vanadium alloy, and made with 2 manufacturing processes (milled and printed) were individually installed in a bovine rib block according to the manufacturer's protocol. CBCT images were acquired with i-CAT and Carestream scanners, randomized, and analyzed without and with the e-Vol DX BAR filter (60 images for each scanner). Implant length, diameter, and thread-to-thread distance were measured by two radiologists, with a stereomicroscopic image of each implant as the reference standard for calculation of distortion in measurements. Repeated measures ANOVA with Bonferroni corrections and intraclass correlation coefficients (ICC) were applied (α = 0.05).</div></div><div><h3>Results</h3><div>The BAR filter significantly reduced distortion in various parameters for specific implants, aligning closely with stereomicroscopic measurements. Titanium and printed implants showed reduced dimensional distortion regardless of BAR filter use. Carestream measurements presented smaller dimensional differences than i-CAT for most implants and parameters, especially without BAR (<em>P</em> < .05). Interexaminer reliability was good to excellent, with ICC ranging from 0.80 to 0.95.</div></div><div><h3>Conclusions</h3><div>The BAR filter can enhance implant dimensional analysis, although variations based on implant material and manufacturing process were observed.</div></div>","PeriodicalId":49010,"journal":{"name":"Oral Surgery Oral Medicine Oral Pathology Oral Radiology","volume":"138 6","pages":"Pages 813-822"},"PeriodicalIF":2.0000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The effect of a blooming artifact reduction filter on the dimensional analysis of implants\",\"authors\":\"Matheus Akira Sakurada DDS, MSc , Luiz Eduardo Gregoris Rabelo DDS, MSc, PhD , Ivonete Barreto Haagsma DDS , Luis Carlos do Carmo Filho DDS, MSc, PhD , Carlos Estrela DDS, MSc, PhD , Isabela Reginaldo DDS , Thais Marques Simek Vega Gonçalves DDS, MSc, PhD\",\"doi\":\"10.1016/j.oooo.2024.08.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><div>To assess the effect of a blooming artifact reduction (BAR) filter on cone beam computed tomography (CBCT) images in the dimensional analysis of dental implants.</div></div><div><h3>Study Design</h3><div>Six types of implants (<em>n</em> = 5 for each type) composed of titanium (3 types), titanium-zirconia alloy, zirconium oxide, and titanium-aluminum-vanadium alloy, and made with 2 manufacturing processes (milled and printed) were individually installed in a bovine rib block according to the manufacturer's protocol. CBCT images were acquired with i-CAT and Carestream scanners, randomized, and analyzed without and with the e-Vol DX BAR filter (60 images for each scanner). Implant length, diameter, and thread-to-thread distance were measured by two radiologists, with a stereomicroscopic image of each implant as the reference standard for calculation of distortion in measurements. Repeated measures ANOVA with Bonferroni corrections and intraclass correlation coefficients (ICC) were applied (α = 0.05).</div></div><div><h3>Results</h3><div>The BAR filter significantly reduced distortion in various parameters for specific implants, aligning closely with stereomicroscopic measurements. Titanium and printed implants showed reduced dimensional distortion regardless of BAR filter use. Carestream measurements presented smaller dimensional differences than i-CAT for most implants and parameters, especially without BAR (<em>P</em> < .05). Interexaminer reliability was good to excellent, with ICC ranging from 0.80 to 0.95.</div></div><div><h3>Conclusions</h3><div>The BAR filter can enhance implant dimensional analysis, although variations based on implant material and manufacturing process were observed.</div></div>\",\"PeriodicalId\":49010,\"journal\":{\"name\":\"Oral Surgery Oral Medicine Oral Pathology Oral Radiology\",\"volume\":\"138 6\",\"pages\":\"Pages 813-822\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-08-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Oral Surgery Oral Medicine Oral Pathology Oral Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2212440324004097\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oral Surgery Oral Medicine Oral Pathology Oral Radiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2212440324004097","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
The effect of a blooming artifact reduction filter on the dimensional analysis of implants
Objective
To assess the effect of a blooming artifact reduction (BAR) filter on cone beam computed tomography (CBCT) images in the dimensional analysis of dental implants.
Study Design
Six types of implants (n = 5 for each type) composed of titanium (3 types), titanium-zirconia alloy, zirconium oxide, and titanium-aluminum-vanadium alloy, and made with 2 manufacturing processes (milled and printed) were individually installed in a bovine rib block according to the manufacturer's protocol. CBCT images were acquired with i-CAT and Carestream scanners, randomized, and analyzed without and with the e-Vol DX BAR filter (60 images for each scanner). Implant length, diameter, and thread-to-thread distance were measured by two radiologists, with a stereomicroscopic image of each implant as the reference standard for calculation of distortion in measurements. Repeated measures ANOVA with Bonferroni corrections and intraclass correlation coefficients (ICC) were applied (α = 0.05).
Results
The BAR filter significantly reduced distortion in various parameters for specific implants, aligning closely with stereomicroscopic measurements. Titanium and printed implants showed reduced dimensional distortion regardless of BAR filter use. Carestream measurements presented smaller dimensional differences than i-CAT for most implants and parameters, especially without BAR (P < .05). Interexaminer reliability was good to excellent, with ICC ranging from 0.80 to 0.95.
Conclusions
The BAR filter can enhance implant dimensional analysis, although variations based on implant material and manufacturing process were observed.
期刊介绍:
Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology is required reading for anyone in the fields of oral surgery, oral medicine, oral pathology, oral radiology or advanced general practice dentistry. It is the only major dental journal that provides a practical and complete overview of the medical and surgical techniques of dental practice in four areas. Topics covered include such current issues as dental implants, treatment of HIV-infected patients, and evaluation and treatment of TMJ disorders. The official publication for nine societies, the Journal is recommended for initial purchase in the Brandon Hill study, Selected List of Books and Journals for the Small Medical Library.