验证表面等离子体共振 (SPR) 生物传感器响应的组合方法

IF 1.8 4区 材料科学 Q3 MATERIALS SCIENCE, MULTIDISCIPLINARY
Aditi Chopra, Girish C Mohanta, Sudipta S Pal
{"title":"验证表面等离子体共振 (SPR) 生物传感器响应的组合方法","authors":"Aditi Chopra, Girish C Mohanta, Sudipta S Pal","doi":"10.1088/2053-1591/ad6f70","DOIUrl":null,"url":null,"abstract":"One of the fundamental challenges of working with surface plasmon resonance (SPR) biosensors is their inherent lack of specificity. Being very sensitive to minute refractive index (RI) changes in their surrounding medium, SPR biosensors are highly susceptible to variations in pH, temperature, and buffer composition. Therefore, it is often necessary to include an additional validation step downstream to SPR biosensing, particularly for clinical analysis. In this proof-of-study work, we have tried to evaluate the utility of surface-enhanced Raman scattering (SERS) tags as secondary labels for validating SPR biosensor response. Accordingly, a Fibre-optic SPR (FO-SPR) biosensor set-up was fabricated by immobilizing anti-BSA antibodies on the sensor platform for capturing and sensing biotinylated-BSA as a model analyte. Subsequently, the bound analyte and the concomitant shift in SPR response were validated by employing streptavidin-functionalized SERS tags. Intriguingly, apart from validation of the SPR response, the SERS tags also significantly improved the sensitivity of the SPR response and provided semi-quantitative information on the bound analyte. Although utilizing SERS tags undermines the label-free tag of SPR biosensors, the huge improvement in sensitivity and specificity of the sensor makes it suitable for clinical analysis. Furthermore, SERS measurements with a portable Raman spectrometer utilized in this study further highlight the potential of this approach for achieving point-of-care (POC) sensing.","PeriodicalId":18530,"journal":{"name":"Materials Research Express","volume":"11 1","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A combinatorial approach to validate the surface plasmon resonance (SPR) biosensor response\",\"authors\":\"Aditi Chopra, Girish C Mohanta, Sudipta S Pal\",\"doi\":\"10.1088/2053-1591/ad6f70\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One of the fundamental challenges of working with surface plasmon resonance (SPR) biosensors is their inherent lack of specificity. Being very sensitive to minute refractive index (RI) changes in their surrounding medium, SPR biosensors are highly susceptible to variations in pH, temperature, and buffer composition. Therefore, it is often necessary to include an additional validation step downstream to SPR biosensing, particularly for clinical analysis. In this proof-of-study work, we have tried to evaluate the utility of surface-enhanced Raman scattering (SERS) tags as secondary labels for validating SPR biosensor response. Accordingly, a Fibre-optic SPR (FO-SPR) biosensor set-up was fabricated by immobilizing anti-BSA antibodies on the sensor platform for capturing and sensing biotinylated-BSA as a model analyte. Subsequently, the bound analyte and the concomitant shift in SPR response were validated by employing streptavidin-functionalized SERS tags. Intriguingly, apart from validation of the SPR response, the SERS tags also significantly improved the sensitivity of the SPR response and provided semi-quantitative information on the bound analyte. Although utilizing SERS tags undermines the label-free tag of SPR biosensors, the huge improvement in sensitivity and specificity of the sensor makes it suitable for clinical analysis. Furthermore, SERS measurements with a portable Raman spectrometer utilized in this study further highlight the potential of this approach for achieving point-of-care (POC) sensing.\",\"PeriodicalId\":18530,\"journal\":{\"name\":\"Materials Research Express\",\"volume\":\"11 1\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-08-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Materials Research Express\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1088/2053-1591/ad6f70\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MATERIALS SCIENCE, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials Research Express","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1088/2053-1591/ad6f70","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

使用表面等离子体共振(SPR)生物传感器的基本挑战之一是其本身缺乏特异性。SPR 生物传感器对周围介质中微小的折射率 (RI) 变化非常敏感,极易受 pH 值、温度和缓冲液成分变化的影响。因此,通常有必要在 SPR 生物传感的下游增加一个额外的验证步骤,尤其是在临床分析中。在这项研究验证工作中,我们试图评估表面增强拉曼散射(SERS)标签作为验证 SPR 生物传感器响应的辅助标签的效用。因此,我们制作了一个光纤 SPR(FO-SPR)生物传感器装置,将抗-BSA 抗体固定在传感器平台上,以捕获和传感生物素化-BSA 作为模型分析物。随后,通过使用链霉亲和素功能化的 SERS 标签,验证了结合的分析物以及随之而来的 SPR 响应变化。有趣的是,除了验证 SPR 响应外,SERS 标签还大大提高了 SPR 响应的灵敏度,并提供了结合分析物的半定量信息。虽然使用 SERS 标签削弱了 SPR 生物传感器的无标签特性,但传感器灵敏度和特异性的大幅提高使其适用于临床分析。此外,本研究利用便携式拉曼光谱仪进行的 SERS 测量进一步凸显了这种方法在实现床旁 (POC) 传感方面的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A combinatorial approach to validate the surface plasmon resonance (SPR) biosensor response
One of the fundamental challenges of working with surface plasmon resonance (SPR) biosensors is their inherent lack of specificity. Being very sensitive to minute refractive index (RI) changes in their surrounding medium, SPR biosensors are highly susceptible to variations in pH, temperature, and buffer composition. Therefore, it is often necessary to include an additional validation step downstream to SPR biosensing, particularly for clinical analysis. In this proof-of-study work, we have tried to evaluate the utility of surface-enhanced Raman scattering (SERS) tags as secondary labels for validating SPR biosensor response. Accordingly, a Fibre-optic SPR (FO-SPR) biosensor set-up was fabricated by immobilizing anti-BSA antibodies on the sensor platform for capturing and sensing biotinylated-BSA as a model analyte. Subsequently, the bound analyte and the concomitant shift in SPR response were validated by employing streptavidin-functionalized SERS tags. Intriguingly, apart from validation of the SPR response, the SERS tags also significantly improved the sensitivity of the SPR response and provided semi-quantitative information on the bound analyte. Although utilizing SERS tags undermines the label-free tag of SPR biosensors, the huge improvement in sensitivity and specificity of the sensor makes it suitable for clinical analysis. Furthermore, SERS measurements with a portable Raman spectrometer utilized in this study further highlight the potential of this approach for achieving point-of-care (POC) sensing.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Materials Research Express
Materials Research Express MATERIALS SCIENCE, MULTIDISCIPLINARY-
CiteScore
4.50
自引率
4.30%
发文量
640
审稿时长
12 weeks
期刊介绍: A broad, rapid peer-review journal publishing new experimental and theoretical research on the design, fabrication, properties and applications of all classes of materials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信