三焦点人工晶体植入白内障手术日本患者的三份患者报告结果问卷。

Clinical ophthalmology (Auckland, N.Z.) Pub Date : 2024-09-04 eCollection Date: 2024-01-01 DOI:10.2147/OPTH.S478292
Takayuki Akahoshi
{"title":"三焦点人工晶体植入白内障手术日本患者的三份患者报告结果问卷。","authors":"Takayuki Akahoshi","doi":"10.2147/OPTH.S478292","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To analyze the patient-reported-outcomes obtained after trifocal intraocular lens (IOL) bilateral implantation in Japanese patients using three different validated questionnaires.</p><p><strong>Methods: </strong>Fifty-three patients implanted with the FineVision HP IOLs (Beaver-Visitec International, Inc. USA) were enrolled in this prospective-study. At 3-months, refraction (spherical equivalent [SE] and cylinder), logMAR uncorrected distance visual acuity (UDVA), and corrected distance visual acuity (CDVA) were obtained. Specifically, patient-reported-outcomes were evaluated using the NEI VFQ-25, the Catquest-9SF, and the PRSIQ questionnaires.</p><p><strong>Results: </strong>The mean SE and refractive cylinder were 0.00±0.22D and -0.07±0.23D, respectively. A 98.11% of eyes were within ±0.50D and 100% were within ±1.00D of the SE. A 93.40% of the eyes showed equal or less than 0.50D of astigmatism and 100% of eyes equal or less than 1.00D. The mean value for monocular UDVA was -0.05±0.07 logMAR and the mean value for monocular CDVA was -0.07±0.06 logMAR. 87.74% and 92.45% of the eyes showed 20/20 or better monocular UDVA and CDVA, respectively, with 97.17% and 98.11% showing 20/25 or better for UDVA and CDVA, respectively. The NEI VFQ-25 outcomes showed very high scores across all categories, with mean general vision, distance and near activities values of 86.70±6.35, 96.23±7.72 and 92.14±10.74, respectively. The outcomes for the Catquest-9SF questionnaire showed that 90.57% of patients did not report difficulty in their everyday-life with their sight, and 100% of them were \"very or quite satisfied\" with their sight at present. The PRSIQ outcomes revealed that 100%, 98.11% and 98.11% of patients did not need glasses or contacts for far, intermediate and near vision, respectively.</p><p><strong>Conclusion: </strong>The results of the patient-reported-outcomes questionnaires indicated that patients implanted bilaterally with the FineVision HP IOL have high vision and health related quality-of-life scores, with a high spectacle independence rate and high patient satisfaction.</p>","PeriodicalId":93945,"journal":{"name":"Clinical ophthalmology (Auckland, N.Z.)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11380849/pdf/","citationCount":"0","resultStr":"{\"title\":\"Three Patient-Reported Outcomes Questionnaires in Japanese Patients Undergoing Cataract Surgery with Trifocal IOL Implantation.\",\"authors\":\"Takayuki Akahoshi\",\"doi\":\"10.2147/OPTH.S478292\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To analyze the patient-reported-outcomes obtained after trifocal intraocular lens (IOL) bilateral implantation in Japanese patients using three different validated questionnaires.</p><p><strong>Methods: </strong>Fifty-three patients implanted with the FineVision HP IOLs (Beaver-Visitec International, Inc. USA) were enrolled in this prospective-study. At 3-months, refraction (spherical equivalent [SE] and cylinder), logMAR uncorrected distance visual acuity (UDVA), and corrected distance visual acuity (CDVA) were obtained. Specifically, patient-reported-outcomes were evaluated using the NEI VFQ-25, the Catquest-9SF, and the PRSIQ questionnaires.</p><p><strong>Results: </strong>The mean SE and refractive cylinder were 0.00±0.22D and -0.07±0.23D, respectively. A 98.11% of eyes were within ±0.50D and 100% were within ±1.00D of the SE. A 93.40% of the eyes showed equal or less than 0.50D of astigmatism and 100% of eyes equal or less than 1.00D. The mean value for monocular UDVA was -0.05±0.07 logMAR and the mean value for monocular CDVA was -0.07±0.06 logMAR. 87.74% and 92.45% of the eyes showed 20/20 or better monocular UDVA and CDVA, respectively, with 97.17% and 98.11% showing 20/25 or better for UDVA and CDVA, respectively. The NEI VFQ-25 outcomes showed very high scores across all categories, with mean general vision, distance and near activities values of 86.70±6.35, 96.23±7.72 and 92.14±10.74, respectively. The outcomes for the Catquest-9SF questionnaire showed that 90.57% of patients did not report difficulty in their everyday-life with their sight, and 100% of them were \\\"very or quite satisfied\\\" with their sight at present. The PRSIQ outcomes revealed that 100%, 98.11% and 98.11% of patients did not need glasses or contacts for far, intermediate and near vision, respectively.</p><p><strong>Conclusion: </strong>The results of the patient-reported-outcomes questionnaires indicated that patients implanted bilaterally with the FineVision HP IOL have high vision and health related quality-of-life scores, with a high spectacle independence rate and high patient satisfaction.</p>\",\"PeriodicalId\":93945,\"journal\":{\"name\":\"Clinical ophthalmology (Auckland, N.Z.)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11380849/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical ophthalmology (Auckland, N.Z.)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2147/OPTH.S478292\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical ophthalmology (Auckland, N.Z.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTH.S478292","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:使用三种不同的有效问卷,分析日本患者双侧植入三焦点眼内人工晶体(IOL)后的患者报告结果:53名植入FineVision HP人工晶体(美国Beaver-Visitec International公司)的患者参加了这项前瞻性研究。3个月后,获得屈光度(球面等效[SE]和圆柱度)、logMAR未矫正距离视力(UDVA)和矫正距离视力(CDVA)。具体而言,使用 NEI VFQ-25、Catquest-9SF 和 PRSIQ 问卷对患者报告的结果进行了评估:结果:SE 和屈光圆柱的平均值分别为 0.00±0.22D 和 -0.07±0.23D。98.11%的眼睛视力在±0.50D以内,100%的眼睛视力在±1.00D以内。93.40%的眼睛散光等于或小于 0.50D,100%的眼睛散光等于或小于 1.00D。单眼 UDVA 平均值为-0.05±0.07 logMAR,单眼 CDVA 平均值为-0.07±0.06 logMAR。单眼 UDVA 和 CDVA 分别有 87.74% 和 92.45% 显示为 20/20 或更好,UDVA 和 CDVA 分别有 97.17% 和 98.11% 显示为 20/25 或更好。NEI VFQ-25 结果显示,所有类别的得分都很高,一般视力、远视力和近视力的平均值分别为 86.70±6.35、96.23±7.72 和 92.14±10.74。Catquest-9SF 问卷的结果显示,90.57% 的患者没有表示在日常生活中遇到视力困难,100% 的患者对目前的视力表示 "非常满意或比较满意"。PRSIQ结果显示,分别有100%、98.11%和98.11%的患者不需要佩戴远、中和近视眼镜或隐形眼镜:患者报告结果问卷调查结果表明,双侧植入 FineVision HP 人工晶体的患者视力和健康相关生活质量得分较高,眼镜独立率较高,患者满意度较高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Three Patient-Reported Outcomes Questionnaires in Japanese Patients Undergoing Cataract Surgery with Trifocal IOL Implantation.

Purpose: To analyze the patient-reported-outcomes obtained after trifocal intraocular lens (IOL) bilateral implantation in Japanese patients using three different validated questionnaires.

Methods: Fifty-three patients implanted with the FineVision HP IOLs (Beaver-Visitec International, Inc. USA) were enrolled in this prospective-study. At 3-months, refraction (spherical equivalent [SE] and cylinder), logMAR uncorrected distance visual acuity (UDVA), and corrected distance visual acuity (CDVA) were obtained. Specifically, patient-reported-outcomes were evaluated using the NEI VFQ-25, the Catquest-9SF, and the PRSIQ questionnaires.

Results: The mean SE and refractive cylinder were 0.00±0.22D and -0.07±0.23D, respectively. A 98.11% of eyes were within ±0.50D and 100% were within ±1.00D of the SE. A 93.40% of the eyes showed equal or less than 0.50D of astigmatism and 100% of eyes equal or less than 1.00D. The mean value for monocular UDVA was -0.05±0.07 logMAR and the mean value for monocular CDVA was -0.07±0.06 logMAR. 87.74% and 92.45% of the eyes showed 20/20 or better monocular UDVA and CDVA, respectively, with 97.17% and 98.11% showing 20/25 or better for UDVA and CDVA, respectively. The NEI VFQ-25 outcomes showed very high scores across all categories, with mean general vision, distance and near activities values of 86.70±6.35, 96.23±7.72 and 92.14±10.74, respectively. The outcomes for the Catquest-9SF questionnaire showed that 90.57% of patients did not report difficulty in their everyday-life with their sight, and 100% of them were "very or quite satisfied" with their sight at present. The PRSIQ outcomes revealed that 100%, 98.11% and 98.11% of patients did not need glasses or contacts for far, intermediate and near vision, respectively.

Conclusion: The results of the patient-reported-outcomes questionnaires indicated that patients implanted bilaterally with the FineVision HP IOL have high vision and health related quality-of-life scores, with a high spectacle independence rate and high patient satisfaction.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信