Abhay N Datarkar, Arwa F Pardiwala, Priyanka Relan, Surendra Daware, Vandana Gadve, Archana Deshpande, Ashlesha Ghormade
{"title":"对患者特定种植体(带支撑基台)界面进行三维有限元分析,分析双侧上颌畸形患者种植体和周围骨质的应力集中情况。","authors":"Abhay N Datarkar, Arwa F Pardiwala, Priyanka Relan, Surendra Daware, Vandana Gadve, Archana Deshpande, Ashlesha Ghormade","doi":"10.4103/njms.njms_155_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine the efficacy and longevity of patient-specific implants (PSIs) with strut abutment design to rehabilitate bilateral maxillectomy defect.</p><p><strong>Materials and methods: </strong>Finite Element Analysis was performed on a PSI with strut abutments to repair a patient's bilateral maxillectomy defect due to COVID associated mucormycosis.</p><p><strong>Results: </strong>The von Mises stress recorded was maximum in the zygomaticomaxillary buttress region, and displacement values were noted to be highest in the posterior-most strut, although both parameters were within acceptable limits, which is favorable.</p><p><strong>Conclusion: </strong>The authors draw the conclusion that a PSI with strut abutments is a workable therapeutic modality for patients with these kinds of abnormalities based on this information.</p>","PeriodicalId":101444,"journal":{"name":"National journal of maxillofacial surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11371289/pdf/","citationCount":"0","resultStr":"{\"title\":\"A 3-Dimensional finite element analysis of patient-specific implant (with strut abutments) interface on stress concentration on the implant and surrounding bone in bilateral maxillary deformities.\",\"authors\":\"Abhay N Datarkar, Arwa F Pardiwala, Priyanka Relan, Surendra Daware, Vandana Gadve, Archana Deshpande, Ashlesha Ghormade\",\"doi\":\"10.4103/njms.njms_155_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To determine the efficacy and longevity of patient-specific implants (PSIs) with strut abutment design to rehabilitate bilateral maxillectomy defect.</p><p><strong>Materials and methods: </strong>Finite Element Analysis was performed on a PSI with strut abutments to repair a patient's bilateral maxillectomy defect due to COVID associated mucormycosis.</p><p><strong>Results: </strong>The von Mises stress recorded was maximum in the zygomaticomaxillary buttress region, and displacement values were noted to be highest in the posterior-most strut, although both parameters were within acceptable limits, which is favorable.</p><p><strong>Conclusion: </strong>The authors draw the conclusion that a PSI with strut abutments is a workable therapeutic modality for patients with these kinds of abnormalities based on this information.</p>\",\"PeriodicalId\":101444,\"journal\":{\"name\":\"National journal of maxillofacial surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11371289/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"National journal of maxillofacial surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/njms.njms_155_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"National journal of maxillofacial surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/njms.njms_155_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/24 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
A 3-Dimensional finite element analysis of patient-specific implant (with strut abutments) interface on stress concentration on the implant and surrounding bone in bilateral maxillary deformities.
Purpose: To determine the efficacy and longevity of patient-specific implants (PSIs) with strut abutment design to rehabilitate bilateral maxillectomy defect.
Materials and methods: Finite Element Analysis was performed on a PSI with strut abutments to repair a patient's bilateral maxillectomy defect due to COVID associated mucormycosis.
Results: The von Mises stress recorded was maximum in the zygomaticomaxillary buttress region, and displacement values were noted to be highest in the posterior-most strut, although both parameters were within acceptable limits, which is favorable.
Conclusion: The authors draw the conclusion that a PSI with strut abutments is a workable therapeutic modality for patients with these kinds of abnormalities based on this information.